Chapter 4 Programmable Parameters
KBS Configuration program allow users to set parameters according to the vehicle actual
working environment so as to be at its best.
The default parameters of the controller are not recommended for all applications. Make
sure set the proper parameters before making any test to avoid danger.
4.1 Step 1
(1)Forward Switch
Value range: Enable and Disable
Functional description: If enabled, the Forward switch will be activated. Please see figure 4.1.
Suggestion: Set according to the practical situation, factory default is Disable.
(2)Foot Switch
Value range: Enable and Disable
Functional description: If enabled,the foot switch will be activated.The controller will not accept
the throttle signal if the foot switch is turned off. Please see figure 4.1.
Suggestion: Set according to the practical situation, factory default is Disable.
Configuration
Pin Status
Running
Status
Forward
Switch
Foot Switch
FWD_SW
(12)
REV_SW
(14)
Foot
(15)
Enable
Disable
OFF
OFF
x
Neutral
OFF
ON
x
Reverse
ON
OFF
x
Forward
ON
ON
x
Neutral
Disable
Enable
x
OFF
OFF
Can
‟t operate
x
ON
OFF
Can
‟t operate
x
ON
ON
Reverse
x
OFF
ON
Forward
Disable
Disable
x
OFF
x
Forward
x
ON
x
Reverse
Note: X means can be on or off
Figure 4.1
(3)Throttle Sensor Type
Value range: 3-wire resistive pot, hall active throttle.
Functional description: Set throttle sensor type.
Suggestion: Set according to the practical situation, factory default is 1-4V throttle type.
(4)Throttle Effective Starting Point
Value range: 10%-40%
Functional description: Set throttle effective starting point
Suggestion: Set according to the practical situation, factory default is 10%.