background image

Connections of the dV-22 PP

Power supply connection M12 plug

The pin assignment of the programmer is the same as the 

pressure switch:

   

Pin 1 :  +Vcc (8...40VDC)

Pin 2 :  Switch output 2

Pin 3 :  GND

Pin 4 :  Switch output 1

Pin 5 :  Analog output

All pins of the plug are connected with the plug of the pressure switch. Thus, the pro-

grammer can be used directly with the application and the functions of the pressure 

switch remain preserved.  
Attention: The switch outputs are inactive (open) during the programming mode. 

Connection to PC (Binder Plug)

The connector plug is used for communication with a PC / 

laptop. The interface cable (K-107 / K-104B) can be con-

nected here.

Pressure switch connection M12 socket

The  pressure  switch  is  connected  to  the  M12  socket.  If  

necessary,  a  M12  extension  cable  (5-pole)  can  be  used 

between the programmer and the pressure switch.

 - 6 -                                                         www.keller-druck.com            

3

2

4

1

5

Coding

Содержание dV-22 PP

Страница 1: ...May 2011 OPERATING MANUAL PRESSURE SWITCH PA 22 PS PROGRAMMER dV 22 PP PROGRAMMING SOFTWARE Pressure Switch Console...

Страница 2: ...pply connection M12 plug 6 Converter connection connector plug 6 Pressure switch connection M12 socket 6 Display7 Navigating in the Menu Functions of the keys 7 Menu structure 8 Programming mode 9 Swi...

Страница 3: ...y 0 5 seconds If a meter is connected to the analog output it must have an internal resistance of at least 30 k Though the pressure switches are already configured at the factory the configuration can...

Страница 4: ...5 2 3 6 4 4 www keller druck com 1 M 12 plug Power supply connection 8 40 V DC 2 5 pole connector Connection to PC laptop with a converter K 107 K 104B 3 M 12 socket Connection of the pressure switch...

Страница 5: ...on Programming with a PC Laptop If an interface cable from KELLER K 107 K 104 B is connected to the programmer programming can be carried out with a PC laptop using the Pressure Switch Con sole softwa...

Страница 6: ...tly with the application and the functions of the pressure switch remain preserved Attention The switch outputs are inactive open during the programming mode Connection to PC Binder Plug The connector...

Страница 7: ...d the status of the switch outputs with LED s LEDs for the indication of the status of the switch outputs Pressure measuring units Pressure value Programmer dV 22 PP 7 Menu Navigation Navigation in th...

Страница 8: ...tch output II Low switching threshold Low Switch output I Switching function Fct Hysteresis window NO NC OFF Switch output II Switching function Fct Hysteresis window NO NC OFF Return to Normal Mode E...

Страница 9: ...functions Fct Various functions can be configured for the switch outputs Hysteresis H When the high switching threshold is exceeded the output closes It only opens again when the value goes below the...

Страница 10: ...nit bar PSI or MPa in which the program displays the pressure values can be selected Read out and programming of the pressure switch By pressing Read out the data of the pressure switch which is conne...

Страница 11: ...pressure switch and the status of the switch outputs can be displayed Press Display to show these values How ever the actual pressure value can only be displayed if the pressure switch has an analog...

Страница 12: ...claration is valid for products of which a drawing marked with the CE sign exists and which are produced according to this drawing This explanation has no validity without such a drawing As criteria f...