1
)
Technical Parameter
Execute Standard
:
GB/T 7724-2008 n=3000
Accuracy Class
:
III
pi =0.5
Input Sensitivity
:
≥1.5uV/e
A/D Conversion Mode
:
adopt Δ
-
Σ technology, 24bit
Load Cell Bridge Voltage
:
DC +5V, 1 to 12pcs 350Ω resistance stain gauge load cell can be connected.
Load Cell Connection Mode
:
6 wires (long distance compensation, compensation distance ≤50 meters)
Display
:
7 units LED, 7 state indicate lights, 3 power indicate lights
,
1AC indicate light
Clock
:
Display year/moth/date, hour/minute/second, auto leap year, leap month. No effect by power-off.
Remote display port
:
current loop/RS232 output
,
bound rate: 600bps transmission distance ≤30meters
Serial communication port:
Transmission Mode
:
RS232
,
Optional RS485 Transmission Distance
:
RS232≤30meters
(
RS485≤1200meters
)
Bound Rate
:
600/1200/2400/4800/9600 Optional
Print port
:
standard parallel output port, can connect with TpuP16 mini-printer(English), KX
-
P1121,KX
-
P1131,LQ300K
+
Ⅱ
,LQ1600K, TM800,LQ-680K,DS-300 and LQ-730K/630K/635K etc.
Data storage
:(
can be customized
)
Vehicle No. and Tare
:
≤200pcs Cargo No.
:
≤100pcs Weighing Record
:
≤500 groups
Power Supply
:
AC
:
AC110~220V
,
50~60Hz Accessorial power supply
:
Outside connect with 6V/10Ah maintenance-free
lead-acid battery. Can be charged by indicator
Operation Environment
Working Temperature
:
0
℃~
40
℃
Working Humidity
:
≤85
%(
RH
)
No condensation
Storage Environment
:
Storage Temperature
:-
20
℃~
60
℃
Storage Humidity
:
≤95
%(
RH
)
No condensation
Size (mm)
:
330 ×220 ×185
Net Weight(Kg)
:
About 1.5
2
)
Installation
2.1 Indicator layout
XK3118K9-19 Front Panel layout Back Side layout
2.2 Connection between load cell and indicator
Instruction
No.
Description
Code
1
load cell E-
E-
2
load cell F-
F-
6
load cell E+
E+
7
load cell F+
F+
8
load cell S-
S-
9
load cell S+
S+
5
SHIELD
SHIELD
Short circuit connects pin
⑥
with pin
⑦
, pin
①
with pin
②
when connected to load cell
with 4 wires!!!!!!
▲
Load cell connect with indicator must be reliable; shield wire of load cell must be connected to ground
reliably.
▲
Load cell and indicator is static sensitive device, taking measures to prevent from static power when using.