www.kelichina.com
Page 25 of 38
Chapter 8 Setting of Scale’s Linearity Adjustment
1. Operation Method:
▲
!
Before this operation, the calibration plug should plug in the 15 pin RS232 jack in the
back of the indicator.
Before revising, load the weight which needs to be revised
(
For example
:
a scale fits to
the linearity requirements on weight 0-30T but not on 40T, then the scale’s revising
load point should be 40T
)
Detailed operations are as follows:
Steps Operation Display
Notes
1
、
Ready
Load the
weight of
revising point
[******]
When the scale has loaded revising point
weight value, the indicator displays
exceeded or lacked weight value;
2. Turn on
the
indicator
and choose
operating
mode
Press[Linearity
Correction]
Enter
[1][1][1][1][1][1
]
,
Press[Enter]
[-------]
[111111]
Ask to enter password
Only when the password is 111111, can the
next step continue
,
otherwise back to the
weighing state
;
3
、
Enter
Revising
Press[0][1]
Press[Enter]
Enter
[4][0][0][0][0]
Press[Enter]
[S 00]
[S 01]
[000000]
[040000]
[040000]
Default is 00 and do not carry on linearity
revising. If the number is bigger than 00
then carry on linearity revising.
Enter 01 and begin linearity revising;
Ask to enter revising point weight value.
Enter weight value to 40000kg
The indicator return to the weighing state
and display weight 40000kg
;