KPCI-3101 — KPCI-3104 Series User’s Manual
About-Trigger acquisition
Use about-trigger acquisition mode (continuous about-trigger mode) when you want to acquire
data both before and after a specific external event occurs. This operation is equivalent to doing
both a pre-trigger and a post-trigger acquisition.
Using software, specify:
•
The dataflow as continuous about-trigger
•
The pre-trigger source as the software trigger
•
The post-trigger source as the external digital (TTL) trigger
•
The retrigger mode as the internal retrigger (if you are using triggered scan mode)
Refer to
for more information on the supported conversion modes; refer to
for information on the supported trigger sources.
NOTE
When using about-trigger acquisition, you cannot use externally-
retriggered scan mode; refer to
for more information on
triggered scan mode.
The about-trigger acquisition starts when you start the operation. When it detects the selected
post-trigger event, the board stops acquiring pre-trigger data and starts acquiring post-trigger
data.
If you are using internally-retriggered scan mode and the post-trigger event has not occurred, the
board continues to acquire pre-trigger data using the internal retrigger clock to clock the opera-
tion. If, however, the post-trigger event has occurred, the board continues to acquire post-trigger
data using the internal retrigger clock to clock the operation.
The about-trigger operation stops when the specified number of post-trigger samples has been
acquired or when you stop the operation. Refer to
for more information on internally-
retriggered scan mode.
illustrates continuous about-trigger mode using a channel-gain list of two entries:
channel 0 and channel 1. In this example, pre-trigger analog input data is acquired continuously
on each clock pulse of the A/D sample clock until the post-trigger event occurs. When the post-
trigger event occurs, post-trigger analog input data is acquired continuously on each clock pulse
of the A/D sample clock.
Figure 2-6
Continuous about-trigger mode
Pre-trigger event occurs
Chan 0
Chan 1
Chan 0
. ..
A/D
Sample
Clock
Post-trigger event occurs
Pre-trigger data acquired
Post-trigger data acquired
Chan 1
Chan 0
Chan 1
Chan 0
Chan 1
Chan 0
Chan 1
Chan 0
Chan 1
Содержание KPCI-3101 Series
Страница 1: ...User s Manual KPCI 3101 3102 3103 3104 Series PCI Bus Data Acquisition Boards 98150 Rev A 10 99...
Страница 10: ...iv...
Страница 15: ...1 Overview...
Страница 21: ...2 Principles of Operation...
Страница 53: ...3 Installation and Configuration...
Страница 78: ...3 26 Installation and Configuration KPCI 3101 KPCI 3104 Series User s Manual...
Страница 79: ...4 Testing the Board...
Страница 82: ...4 4 Testing the Board KPCI 3101 KPCI 3104 Series User s Manual...
Страница 83: ...5 Calibration...
Страница 86: ...5 4 Calibration KPCI 3101 KPCI 3104 Series User s Manual...
Страница 87: ...6 Troubleshooting...
Страница 94: ...6 8 Troubleshooting KPCI 3101 KPCI 3104 Series User s Manual...
Страница 95: ...A Specifications...
Страница 107: ...B Connector Pin Assignments...
Страница 111: ...C Systematic Problem Isolation...
Страница 145: ...This page intentionally left blank...
Страница 146: ...Keithley Instruments Inc 28775 Aurora Road Cleveland Ohio 44139 Printed in the U S A...