Keithley 7702 Скачать руководство пользователя страница 2

 

WARRANTY

 

Keithley Instruments, Inc. warrants this product to be free from defects in material and workmanship for a period of 1 year
from date of shipment.

Keithley Instruments, Inc. warrants the following items for 90 days from the date of shipment: probes, cables, rechargeable
batteries, diskettes, and documentation.

During the warranty period, we will, at our option, either repair or replace any product that proves to be defective.

To exercise this warranty, write or call your local Keithley representative, or contact Keithley headquarters in Cleveland, Ohio.
You will be given prompt assistance and return instructions. Send the product, transportation prepaid, to the indicated service
facility. Repairs will be made and the product returned, transportation prepaid. Repaired or replaced products are warranted for
the balance of the original warranty period, or at least 90 days.

 

LIMITATION OF WARRANTY

 

This warranty does not apply to defects resulting from product modification without Keithley’s express written consent, or
misuse of any product or part. This warranty also does not apply to fuses, software, non-rechargeable batteries, damage from
battery leakage, or problems arising from normal wear or failure to follow instructions.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. THE REMEDIES PRO-
VIDED HEREIN ARE BUYER’S SOLE AND EXCLUSIVE REMEDIES.

NEITHER KEITHLEY INSTRUMENTS, INC. NOR ANY OF ITS EMPLOYEES SHALL BE LIABLE FOR ANY DIRECT,
INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF ITS
INSTRUMENTS AND SOFTWARE EVEN IF KEITHLEY INSTRUMENTS, INC., HAS BEEN ADVISED IN ADVANCE
OF THE POSSIBILITY OF SUCH DAMAGES. SUCH EXCLUDED DAMAGES SHALL INCLUDE, BUT ARE NOT LIM-
ITED TO: COSTS OF REMOVAL AND INSTALLATION, LOSSES SUSTAINED AS THE RESULT OF INJURY TO ANY
PERSON, OR DAMAGE TO PROPERTY.

 

Keithley Instruments, Inc. 

 

28775 Aurora Road • Cleveland, Ohio 44139 • 440-248-0400 • Fax: 440-248-6168 

 

1-888-KEITHLEY (534-8453) • www.keithley.com

Sales Offices:

 

 

 

BELGIUM:

 

 

Bergensesteenweg 709 • B-1600 Sint-Pieters-Leeuw • 02-363 00 40 • Fax: 02-363 00 64

 

CHINA:

 

 

Yuan Chen Xin Building, Room 705 • 12 Yumin Road, Dewai, Madian • Beijing 100029 • 8610-82251886 • Fax: 8610-82251892

 

FINLAND: 

 

Halsuantie 2 • 00420 Helsinki, Finland • 09-53 06 65 60 • Fax: 09-53 06 65 65

 

FRANCE:

 

 

3, allée des Garays • 91127 Palaiseau Cédex • 01-64 53 20 20 • Fax: 01-60 11 77 26

 

GERMANY:

 

 

Landsberger Strasse 65 • 82110 Germering • 089-84 93 07-40 • Fax: 089-84 93 07-34

 

GREAT BRITAIN: 

 

Unit 2 Commerce Park, Brunel Road • Theale, Berkshire RG7 4AB • 0118 -929 75 00 • Fax: 0118- 929 75 19

 

INDIA:

 

 

1/5, Eagles Street • Langford Town • Bangalore 560 025 • 080 212 80-27 • Fax: 080 212 80 05

 

ITALY:

 

 

Viale San Gimignano, 38 • 20146 Milano • 02-48 39 16 01 • Fax: 02-48 30 22 74

 

JAPAN:

 

 

New Pier Takeshiba North Tower 13F • 11-1, Kaigan 1-chome • Minato-ku, Tokyo 105-0022 • 81-3-5733-7555 • Fax: 81-3-5733-7556

 

KOREA:

 

 

2FL., URI Building • 2-14 Yangjae-Dong • Seocho-Gu, Seoul 137-888 • 82-2-574-7778 • Fax: 82-2-574-7838

 

NETHERLANDS:

 

  Postbus 559 • 4200 AN Gorinchem • 0183-63 53 33 • Fax: 0183-63 08 21

 

SWEDEN:

 

 

c/o Regus Business Centre • Frosundaviks Allé 15, 4tr • 16970 Solna • 08-50 90 46 00 • Fax: 08-655 26 10

 

TAIWAN:

 

 

13F-3, NO. 6, Lane 99, Pu-Ding Road, Hsinchu, Taiwan, ROC. • 886-3-572-9077 • Fax: 886-3-572-9031

 

5/03

Содержание 7702

Страница 1: ...Model 7700 7702 and 7703Multiplexer Modules User s Guide PA 695 Rev C 8 03 A G R E A T E R M E A S U R E O F C O N F I D E N C E...

Страница 2: ...CT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF ITS INSTRUMENTS AND SOFTWARE EVEN IF KEITHLEY INSTRUMENTS INC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH D...

Страница 3: ...that a shock hazard exists when voltage levels greater than 30V RMS 42 4V peak or 60VDC are present A good safety practice is to expect that hazardous voltage is present in any unknown circuit before...

Страница 4: ...electric shock and fire replacement components in mains circuits including the power transformer test leads and input jacks must be purchased from Keithley Instru ments Standard fuses with applicable...

Страница 5: ...s manual Not valid INSERTION LOSS 50 Source 50 Load w Internal DMM w o Internal DMM 0 1dB 1MHz 1MHz 3db 2MHz 50MHz Channels 24 and 25 are open Refer to ROUTe MULTiple command in 27xx User s manual COM...

Страница 6: ...200pF CROSS TALK 10MHz 50 Load 40dB INSERTION LOSS 50 Source 50 Load 0 1dB below 1MHz 3dB below 2MHz COMMON MODE VOLTAGE 300V between any terminal and chassis ENVIRONMENTAL OPERATING ENVIRONMENT Spec...

Страница 7: ...TERMINAL AND EARTH 109 400pF CROSS TALK 1 MHz 50 Load 40dB INSERTION LOSS 50 Source 50 Load 0 35dB below 1MHz 3dB below 2MHz COMMON MODE VOLTAGE 300V between any terminal and chassis ENVIRONMENTAL OPE...

Страница 8: ...KEITHLEY 1 888 543 5483 U S only or Telefax 440 498 2990 Instrument Products WARNING Before operating the Model 27xx with an accessory card verify that the card is properly installed and the mounting...

Страница 9: ...DUT but you must use multiple channel operation to close channels Screw terminal access Model 7700 and 7702 Turn the access screw to unlock and open the cover Press in the access screw to lock Figure...

Страница 10: ...ections AMP and LO common connections to the DMM are also provided Figure 2 Model 7700 screw terminal channel designations CH7 H L CH8 H L CH9 H L CH10 H L H L CH21 H L CH22 AMPS LO H L CH11 H L CH12...

Страница 11: ...crew terminal access located at the front of this document 3 Using a small flat blade screwdriver loosen terminal screws and install wires as desired Figure 3 shows connections to channels 1 and 2 4 R...

Страница 12: ...Color Description AMPS COM H L INPUT H L SENSE H L CH1 H L CH2 H L CH3 H L CH4 H L CH5 H L CH6 H L CH7 H L CH8 H L CH9 H L CH10 H L CH11 H L CH12 H L CH13 H L CH14 H L CH15 H L CH16 H L CH17 H L CH18...

Страница 13: ...ire connections AMP and LO common connections to the DMM are also provided Wiring procedure WARNING The information in this section is intended for qualified service personnel Do not attempt to perfor...

Страница 14: ...L CH8 H L CH9 H L CH10 H L CH11 H L CH12 H L CH13 H L CH14 H L CH15 H L CH16 H L CH17 H L CH18 H L CH19 H L CH20 H L H L CH21 H L CH22 H L CH23 H L CH24 H L CH26 H L CH28 H L CH32 H L CH34 H L CH36 H...

Страница 15: ...odel 7702 Connection log Make a copy of Table 2 and affix it to the cover of the Model 7702 Use this to record connection information and channel descriptions as needed TE122 TE121 Cable tie 2 places...

Страница 16: ...L CH23 H H CH3 L L CH24 H H CH4 L L CH25 H H CH5 L L CH26 H H CH6 L L CH27 H H CH7 L L CH28 H H CH8 L L CH29 H H CH9 L L CH30 H H CH10 L L CH31 H H CH11 L L CH32 H H CH12 L L CH33 H H CH13 L L CH34 H...

Страница 17: ...o perform this procedure unless qualified to do so Do not exceed the maximum specifications for the Model 7703 module NOTE When looking at the rear connectors of the Model 7703 module the connector on...

Страница 18: ...19 HI 19 9 LO 31 15 LO 43 29 LO 2 Sense LO 27 5 LO 39 19 LO 20 10 HI 32 16 HI 44 30 HI 4 Input HI 28 6 HI 40 20 HI 21 10 LO 33 16 LO 45 30 LO 6 Input LO 29 6 LO 41 20 LO 22 11 HI 34 25 HI 46 31 HI 18...

Страница 19: ...nection log Model 7703 Channel Color Description Description Color Channel INPUT H L SENSE H L CH1 H H CH17 L L CH2 H H CH18 L L CH3 H H CH19 L L CH4 H H CH20 L L CH5 H H CH21 L L CH6 H H CH22 L L CH7...

Страница 20: ......

Страница 21: ...www keithley com cn Japan Tokyo 81 3 5733 7555 Fax 81 3 5733 7556 www keithley jp Finland Helsinki 09 5306 6560 Fax 09 5306 6565 www keithley com Korea Seoul 82 2 574 7778 Fax 82 2 574 7838 www keithl...

Отзывы: