Introduction 

The easy-to-use Model 4200-SCS Semiconductor Characterization 

System performs lab grade DC and pulse device characterization, 

real-time plotting, and analysis with high precision and sub-femtoamp 

resolution. The 4200-SCS offers the most advanced capabilities 

available in a fully integrated characterization system, including a 

complete, embedded computer with a Microsoft Windows operating 

system and mass storage. Its self-documenting point-and-click 

interface speeds and simplifies the process of taking data, so users 

can begin analyzing their results sooner. 

CD-ROM contents 

The CD-ROM that is included with your instrument contains: 

 

Installation files for KITE.

 These can only be installed on the 

Model 4200-SCS. 

 

Manuals & Specs.

 PDFs of the User Manual, Reference 

Manual, Technical Data, and Quick Start Guide documents. 

 

Release Notes.

 The latest software release notes and license 

agreement. 

 

Application Notes.

 Application notes that demonstrate specific 

applications. 

 

Technical Notes.

 Specific technical information. 

 

White Papers. 

General discussions of testing. 

 

Data Sheets.

 Data sheets for the 4200-SCS and related 

equipment. This also includes brochures and other information. 

For additional support information, see 

http://www.keithley.com/support

Содержание 4200-SCS-PK3-903-01

Страница 1: ...Model 4200 SCS PK3 Quick Start Guide...

Страница 2: ...work on live circuits perform safe installations and repair products Only properly trained service personnel may perform installation and service procedures Keithley Instruments products are designed...

Страница 3: ...in the specifications and operating information and as shown on the instrument or test fixture panels or switching card When fuses are used in a product replace with the same type and rating for cont...

Страница 4: ...leaner directly to the instrument or allow liquids to enter or spill on the instrument Products that consist of a circuit board with no case or chassis e g a data acquisition board for installation in...

Страница 5: ...users can begin analyzing their results sooner CD ROM contents The CD ROM that is included with your instrument contains Installation files for KITE These can only be installed on the Model 4200 SCS...

Страница 6: ...dard accessories CD ROMs and optional accessories such as rack mount hardware 4 Remove the packaging insert 5 Remove the 4200 SCS from the bottom Do not lift the 4200 SCS from the front bezel Lifting...

Страница 7: ...IV component test fixture with sample devices 3 Model 4200 RPC 2 remote PreAmp cables two 4 Model 4200 MTRX ultra low noise SMU triaxial cables four 5 Model 236 ILC 3 safety interlock cable 6 Model 42...

Страница 8: ...dry locations Keithley Instruments Inc products are only rated for dry locations Read and comply with the specifications of all instruments in the system The overall allowed signal levels may be const...

Страница 9: ...all safety warnings provided with each of the instruments in your system Install the instrument The Model 4200 SCS can be used on a bench or in a rack Please see the instructions that came with your...

Страница 10: ...ow voltage fixtures such as the Model 8101 PIV that is included with this bundle are intended for applications that are less than 40 volts For these applications an interlock is not needed High voltag...

Страница 11: ...ections for testing If you are testing discrete devices you need a test fixture that is equipped with 3 lug triaxial connectors The Model 8101 PIV test fixture that is included with the Model 4200 SCS...

Страница 12: ...V Test section graphic Make connections for the C V test Power up the instrument The 4200 SCS operates from a line voltage of 100 V to 240 V at a frequency of 50 Hz or 60 Hz Make sure the operating v...

Страница 13: ...of the power cord to a grounded AC outlet 4 Turn on the instrument by pressing the front panel POWER switch to the ON position The instrument starts up and loads the Microsoft Windows operating syste...

Страница 14: ...Make connections for the I V test If you are using the supplied test fixture connect the MOSFET and test fixture as shown in this diagram...

Страница 15: ...nMOSFET DUT 1 Plug into the test socket that is labeled DC ONLY 5 Model 8101 PIV Component Test Fixture 1 6 Model 4200 PA Remote PreAmp 2 7 Model 4200 SMU module 2 8 Model 4210 SMU module 2 Perform an...

Страница 16: ...with the Model 4200 SCS PK3 you do not need to change these parameters Run the vds id test KITE can run a single test or a sequence of tests To run a single test check the test and click it The test...

Страница 17: ...run In the following example only one test is run To run the vds id test 1 In the navigator double click the vds id test to highlight it and display the data sheets for the test 2 On the toolbar click...

Страница 18: ...spreadsheets To view the results of the vds id test 1 Click the Sheet tab for the test 2 Select the tab below the data for the type of information you would like to view Data Displays the data Calc P...

Страница 19: ...se Selected Sheets 4 Click OK To print the all sheets 1 Select File then Print 2 Choose Entire Workbook 3 Click OK To export the information 1 Open the worksheet that contains the data to be exported...

Страница 20: ...ox and use different colors for the graph series These options are available through the Graph Settings button To customize a graph 1 Right click the graph The Graph Settings menu is displayed You can...

Страница 21: ...4 Select the colors for each series 5 Click OK The series and color information is displayed...

Страница 22: ...Make connections for the C V test If you are using the supplied test fixture connect the nMOSFET and test fixture as shown in this diagram...

Страница 23: ...le 4 Model 8101 PIV Component Test Fixture 1 5 8101 309 nMOSFET with S D B connected together DUT 1 Plug into PULSE IV test socket 6 Model 4210 CVU Module 1 Perform a C V test on an nMOSFET 1 In the P...

Страница 24: ...vice is connected to the CVH1 and the CVL1 terminals of the Model 4210 CVU The default setting shows the DC bias is swept from 5 V to 5 V in 0 2 V steps with a 1 MHz capacitance measurement taken at e...

Страница 25: ...l is on 3 When the test is complete the Run Test button turns green View results of the cv nmosfet test To view data from the cv nmosfet test you can use the data sheets which are similar to Microsoft...

Страница 26: ...se Selected Sheets 4 Click OK To print the all sheets 1 Select File then Print 2 Choose Entire Workbook 3 Click OK To export the information 1 Open the worksheet that contains the data to be exported...

Страница 27: ...b for the test A sample graph is shown here In this example the C V curve is measured between the gate and the source drain bulk Notice that the COX CFB and VFB parameters are extracted and displayed...

Страница 28: ...Model 4200 MTRX from the SMU The mini triaxial connector is a locking connector To remove it pull the knurled part of the connector back A configuration error has been detected and I cannot launch KIT...

Страница 29: ...ic information about using the system plus application based examples that will help familiarize you with the instrument Model 4200 SCS Reference Manual Provides detailed information about all feature...

Страница 30: ......

Отзывы: