Section 7: SCPI command reference
Series 2280 Precision DC Power Supply Reference Manual
7-148
077085503 / March 2019
Example
TRAC:TRIG:VOLT 20
TRAC:TRIG:VOLT?
The value of the voltage threshold is set to 20.
Also see
:TRACe[n]:TRIGger:VOLTage:STATe
(on page 7-148)
:TRACe[n]:TRIGger:VOLTage:DIRection
(on page 7-147)
:TRACe[n]:TRIGger:VOLTage:STATe
This command determines whether the voltage level trigger function is enabled.
Type
Affected by
Where saved
Default value
Command and query
Power cycle
Not applicable
0 (OFF)
Usage
:TRACe[n]:TRIGger:VOLTage:STATe <state>
:TRACe[n]:TRIGger:VOLTage:STATe?
<
state
>
ON
or
1
: Enable the voltage level trigger function
OFF
or
0
: Disable the voltage level trigger function
Example
TRAC:TRIG:VOLT:STAT 1
TRAC:TRIG:VOLT:STAT?
The voltage level trigger function is enabled.
Also see
:TRACe[n]:TRIGger:VOLTage[:LEVel]
:TRACe[n]:TRIGger:VOLTage:DIRection
(on page 7-147)