manualshive.com logo in svg
background image

15

AIR300 LEG EXTENSION PRO

OPERATION MANUAL

MAINTENANCE

PREVENTATIVE MAINTENANCE SCHEDULE

Daily

• 

Check for safe and proper function of the equipment (perform “Proper Operation 

Check,” page 11).

• 

Clean the chrome and paint where applicable.

• 

Wipe down the equipment with a clean cloth. If necessary, use water and mild soap 

(neutral,  non-caustic).  Target  areas  that  come  in  contact  with  sweat.  Wipe  dry  the 

equipment.  

Monthly

• 

Check externally visible screws are fastened properly with no looseness. 

• 

Clean and lubricate Cylinder Rods.

• 

Inspect Air Line for kinks, tears, or breaks.

• 

Inspect Frame for any weakening in weld areas, and other connected areas.

Quarterly

• 

Lubricate Pivot Bushings.

• 

Inspect Exhaust Mufflers and Air Filter for discoloration; replace if necessary.

• 

Verify compressor(s) cycle on/off between 100-120 psi (6.89–8.27 bar).

Annually and 
other Required 
Maintenance

• 

For complete instructions, see page 17 “Annual Maintenance.” 

• 

Battery Replacement. The low battery signal (“Lo-bA”) will appear on the Power Display 

when it is time to replace the batteries. Refer to page 16 “Battery Replacement” for 
complete instructions.

NOTE: 

Your Keiser Air Compressor (not included with your Air300 Leg Extension Pro) 

requires basic annual maintenance. Contact Keiser Customer Support for Air Compressor 
operator manual or download at keiser.com/support

 (search: Air Compressor manuals).

Weekly

• 

Check parts most susceptible to wear are not damaged or broken:

 

– Upholstery, Belt/Linkage System, Thumb Buttons, and Hand Grips.

• 

Wax chrome and paint where applicable; wax upholstery.

• 

Clean Hand Grips.

• 

Inspect Air Line Filter.

Contact Keiser Customer Support for replacement parts order, or for any matters regarding the safe operation of your 

Air300 Leg Extension Pro (see back cover for contact information).

IMPORTANT: 

Do not use household or industrial cleaners as they contain caustic chemicals that can destroy the paint finish 

and cause corrosion. Use only 

mild soap/detergent (neutral, non-caustic) to clean.

CAUTION: SERVICE AND REPAIR SHALL ONLY BE PERFORMED BY KEISER-CERTIFIED TECHNICIANS. 
Failure to follow these instructions can result in serious injury.

CAUTION: THE HIGHEST LEVEL OF EQUIPMENT SAFETY CAN ONLY BE ENSURED IF THE EQUIPMENT IS 
REGULARLY INSPECTED FOR DAMAGE AND WEAR.

 Immediately replace damaged, worn, or broken parts. Do not 

use the Air300 Leg Extension Pro until all repairs have been completed and tested by a Keiser-certified technician.

Содержание LEG EXTENSION PRO AIR300

Страница 1: ...LEG EXTENSION PRO MODEL 1133XX OPERATION MANUAL AIR300 STRENGTH CARDIO FUNCTIONAL...

Страница 2: ...COMPLIANCE NOTICES 18_SAFETY NOTIFICATIONS 19_ELECTROMAGNETIC COMPATIBILITY EMC 19_US FCC COMPLIANCE STATEMENT 19_DISPOSAL 20 WARRANTY STATEMENT Keiser the Keiser logo and other trademarks associated...

Страница 3: ...ERAL INFORMATION INTRODUCTION Register your Air300 Leg Extension Pro to stay informed of safety notifications and for faster more accurate warranty service Scan the QR Code to the right to access the...

Страница 4: ...nseriousinjuryorproperty damage Bring the Exercise Arms to the start position in a controlled manner to safely exit the equipment If at any time you are not able to control your legs during exercise p...

Страница 5: ...a hazardous situation that if not avoided could result in minor or moderate injury IMPORTANT Indicates information considered critical but not hazard related IMPORTANT SAFETY INFORMATION CONTINUED Mai...

Страница 6: ...Back Maximum user weight limit 441 lbs 200 kg AIR STORAGE TANKS The equipment contains two air storage tanks air accumulator with the following operating parameters POWER 1 5V D Alkaline Batteries qua...

Страница 7: ...TEM WARNING Never connect equipment to an air source capable of exceeding 120 psi 8 27 bar Over pressurizing Keiser pneumatic equipment may cause tubing to burst breakage of equipment abnormal operati...

Страница 8: ...sion Pro Power Display Cylinders Seat Back Exercise Arms Processor Box Belts Seat Instruction Placard not shown Leg Cushions Seat Lever Increase Decrease Thumb Buttons Quick Disconnect QD with Tube An...

Страница 9: ...monitoring systems may be inaccurate Over exercising may result in serious injury or death If you feel faint stop exercising immediately Peak Power not suitable for use in applications where the healt...

Страница 10: ...s inserted and the previous corresponding set was a normal workout set it displays the resistance used for that set When an eChip is inserted and the previous corresponding set was a Power Test it dis...

Страница 11: ...ed the Power Display remains blank see Battery Replacement procedure page 16 A Thumb Buttons and Display press Thumb Buttons to check for proper operation and the Display powers on B Upholstery Seat a...

Страница 12: ...he lever to move backward so your knees align with the machine pivot point 2 Grasp the Handgrips and adjust the resistance with the Thumb Buttons 1 2 Figure 8 How to Use the Air300 Leg Extension Pro F...

Страница 13: ...t the knee Move your feet up and at the same time to full knee extension move legs at the same level Keep your back supported by the Seat Back during movement ECCENTRIC PHASE DOWNWARD MOVEMENT Return...

Страница 14: ...testing guidelines START TEST Press and hold both Thumb Buttons until 6 r Test Mode displays in the RESISTANCE window then release the Thumb Buttons NOTE TARGET REPS window displays P1 Power Test Set...

Страница 15: ...Your Keiser Air Compressor not included with your Air300 Leg Extension Pro requires basic annual maintenance Contact Keiser Customer Support for Air Compressor operator manual or download at keiser co...

Страница 16: ...d remove the cover 2 Remove the 2 D batteries by carefully pulling outtheBatterySleeve followmanufacturer s recommendations for handling maintaining and disposing of batteries 3 Observe the correct po...

Страница 17: ...cate Cylinder Rods Wipe the Cylinder Rods clean and coat lightly with clean SAE 30 motor oil or with a silicon based spray 6 Visual inspection of Belts and Linkage Belts are free of cracks frayed edge...

Страница 18: ...ociated with the disposal of waste products residues including disposal of the equipment itself at the end of its useful life The Air300 Leg Extension Pro contains electronic circuit assemblies 2 alka...

Страница 19: ...L ELECTROMAGNETIC COMPATIBILITY EMC DISPOSAL This equipment contains electrical or electronic components alkaline batteries and a sealed lithium coin cell battery that must be disposed of properly to...

Страница 20: ...ort warranty If you have any questions about your warranty please contact Keiser Customer Support at 1 559 256 8000 and via live chat at keiser com support Monday Friday 9 am to 5 pm Pacific Time or b...

Отзывы: