manualshive.com logo in svg
background image

09

OPERATION MANUAL

FUNCTIONAL TRAINER

LINE 1 - RESISTANCE

The Resistance window displays the current resistance or OFF. The current resistance may be changed by using the Thumb 
Buttons located on the Functional Trainer. When the window displays OFF, the machine enters a low power consumption 
sleep mode to increase battery life. Normal operation may be resumed by pressing either Thumb Button or by inserting the 
eChip. If this window displays the low battery signal (“Lo-bA”), the batteries are getting weak and should be replaced soon 
(two D batteries per Functional Trainer. Refer to page 14 "Battery Replacement" for complete instructions).

LINE 2 - SET OR REPETITIONS

This window displays the current repetition count except immediately after an eChip is first inserted, in which case it displays 

the current set. The set count may range from 1 to 9 and is signaled by the appearance of three horizontal bars in the left 

digit. The number of sets is defined as the number of sets of exercises performed in a four-hour period. Once four hours have 

passed, the machine assumes that the user is returning for a new visit. The repetition count may range from 0 to 99. The 
repetition count may be reset by momentarily pressing both increase and decrease (+/-)Thumb Buttons simultaneously. In 
Power Test mode, the window will display the repetition count per test section (refer to page 11 “Power Test” for complete 
instructions).

LINE 3- TARGET REPS

The Target Reps window displays the number of repetitions performed on the corresponding set of the previous visit, if that 
set was a normal workout set and an eChip is inserted. If the corresponding set of the previous visit was a Power Test, the 
display will show “Pr.” When in Power Test mode, the window will display “P1” during the low resistance test set and “P2” 
during the high resistance test set (refer to page 11 “Power Test” for complete instructions).

LINE 4 - CURRENT POWER / PERCENT OF PEAK POWER

The Current Power window can display 4 different values. During an exercise set, it displays the percent of peak power 

achieved for the most recent repetition. At the end of a Power Test, this window displays the resistance to use to achieve 

maximum power. When an eChip is inserted and the previous corresponding set was a normal workout set, it displays the 

resistance used for that set. When an eChip is inserted, and the previous corresponding set was a Power Test, it displays the 

resistance to use to achieve maximum power. When the calculated resistance to achieve maximum power is being displayed, 
it flashes. In summary, during an exercise set, this window displays the power for the current rep, at the end of a Power 
Test it is the resistance to use for training at maximum power and when an eChip is inserted it is the resistance to set into 
the window above before exercising.

LINE 5 - PEAK POWER

The Peak Power window displays the highest power that has occurred during this workout or since the data was last reset.

LINE 6 - MACHINE ADJUSTMENT

When using the eChip, the Machine Adjustments display Exercise Number and Arm Adjustment of the Functional Trainer. 

The adjustments in each of the windows may be changed by pressing the arrows located directly above/below each window. 

EXERCISE NUMBER

: Input your designated exercise number into the Power Display (any numbering 0 — 99) to track 

exercises performed and record onto your eChip.

ARM ADJUSTMENT

: Input the Arm position in the L Adj./R Adj. windows.

NOTE: The adjustments may only be changed immediately after the eChip is inserted and before the third repetition has 
occurred. Once three repetitions are performed, the machine adjustments cannot be changed until the eChip has been 
removed and reinserted. Machine adjustments apply to a machine and cannot be changed from set to set.

LINE 7 - eCHIP READER

The eChip Reader, located at the bottom right of the Power Display, receives and reads your eChip data. 

LINE 8 - eCHIP

The eChip collects workout data and can store up to 24 separate equipment models (up to 4 equipment position settings per 

model) and up to 240 separate workout sets across Keiser Air and Infinity Series. Designed as an electronic replacement for 
the hand-written exercise card, the eChip enables recall and set-up of the exercise equipment upon the next workout. The 
Keiser eChip software allows saved eChip data to be viewed, stored, and exported (.csv file format) for analysis.

NOTE: Three user eChips (red color) come standard with your Functional Trainer. The Keiser USB Power Kit (a USB adaptor to 
transfer data from your eChip to your computer and Time Set eChips to set the time zone/time on your Functional Trainer) is 
available. For parts order, contact Keiser Customer Support by telephone at 1 559 256 8000, online 24/7 at 

keiser.com/support

or by email at [email protected].
Keiser eChip software system requirements, download, and user manual available at http://manuals.keiser.com/Software/E-Card

DISPLAY FEATURES

Содержание INFINITY 3020XP

Страница 1: ...FUNCTIONAL TRAINER MODEL 3020XP OPERATION MANUAL INFINITY SERIES STRENGTH CARDIO FUNCTIONAL...

Страница 2: ...ENT 15_ANNUAL SERVICING 16 REGULATORY AND COMPLIANCE NOTICES 16 WARRANTY STATEMENT Keiser the Keiser logo and other trademarks associated with Keiser products referred to in this publication are trade...

Страница 3: ...support or by email at service keiser com Yours in Health Keiser Corporation Register your Functional Trainer to stay informed of safety notifications and for faster more accurate warranty service Sca...

Страница 4: ...ccessory during exercise Ensure hook and loop type accessories are fastened firmly before exercise Carefully returntheCableAccessorytothestartpositionbeforegrip is released IMPORTANT SAFETY INFORMATIO...

Страница 5: ...on Ifunreadable or missing contact Keiser Corporation for a replacement by telephone at 1 559 256 8000 online 24 7 at keiser com support or by email at service keiser com SAFETY AND SERIAL NUMBER LABE...

Страница 6: ...cordingly to allow for full range operation When Functional Trainers are placed adjacent to each other the Training Space may be shared Actual Cable Length may vary based on Accessory type user height...

Страница 7: ...justment Knob 13 Accessory Hook 7 Clevis 4 Arm Position Plate 14 9 Instructional Placard Increase Decrease Thumb Buttons 8 Quick Disconnect with Tube 10 OPERATION Free standing Functional Trainer 12 i...

Страница 8: ...OPERATION MANUAL FUNCTIONAL TRAINER 5 8 7 1 3 2 6 4 EXERCISE NUMBER L ADJ POWER DISPLAY Figure 5 Power Display Overview When using the eChip ensure that it is fully inserted into the slot as shown R A...

Страница 9: ...ious corresponding set was a Power Test it displays the resistance to use to achieve maximum power When the calculated resistance to achieve maximum power is being displayed it flashes In summary duri...

Страница 10: ...hold the spring loaded Adjustment Knob 3 Move the Arm to desired position setting 4 Releasethespring loadedAdjustmentKnobatthedesired position setting WARNING Ensure Adjustment Knob is fully engaged...

Страница 11: ...esult in serious injury The Power Test may be performed with or without an eChip To start the Power Test follow the instructions below 1 Press and hold both Thumb Buttons for approximately three secon...

Страница 12: ...NE Consult your physician before beginning any exercise program To help ensure a safe comfortable and effective workout remember to Explosive Hip Flexion Figure 12 Sample Basic Functional Trainer Exer...

Страница 13: ...page 14 Battery Replacement for complete instructions For establishments with multiple Functional Trainer machines replacement of all Power Display batteries at the same time is recommended NOTE Your...

Страница 14: ...ut finger tight 6 IMPORTANT Avoid pinching the Air Line Route the Air Line through the Back Cover notch Reposition the Back Cover onto the Functional Trainer align all screw holes and fasten with the...

Страница 15: ...lean and coat lightly with clean SAE 30 motor oil or with a silicon based spray 5 Replace Air Filter if element is dirty element turns a bright pink or red color Tools required Small Needle Nose Plier...

Страница 16: ...ons However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determin...

Отзывы: