OPERATION MANUAL

FUNCTIONAL TRAINER

MAINTENANCE

PREVENTATIVE MAINTENANCE SCHEDULE

Daily

• 

Wipe down the external body/parts using a moist cloth and a mild detergent (neutral, 

non-caustic). Wipe dry the equipment.

• 

Check that parts most susceptible to wear are not damaged or broken:

 

– Pulleys, Cable, Cable Link, Handle, Thumb Buttons, and Adjustment Plunger.

• 

Check to ensure that the Functional Trainer is in safe and proper working order:

 

The Functional Trainer is securely fastened to the base (floor mount or free-

standing). There should be no movement of the unit in any direction during use.

 

– Press the “+” and then “-” Thumb Buttons a few times to ensure air cycles 

through and that the Power Display powers on.

 

– Cable travels freely and smoothly without binding.

Monthly

• 

Inspect Air Line for kinks, tears, or breaks.

• 

Clean the external body/parts thoroughly, targeting areas that come in contact with 

sweat, using a moist cloth and a mild detergent (neutral, non-caustic). Wipe dry the 
equipment.

Quarterly

• 

Check mount hardware (wedge anchors) and externally visible screws are fastened with 

no looseness. There should be no movement of the unit in any direction during use.

Annually and 
other Required 
Maintenance

• 

For complete instructions, see page 15 “Annual Servicing.” 

• 

Battery Replacement. The low battery signal (“Lo-bA”) will appear on the Power Display 
when it is time to replace the batteries. Refer to page 14 “Battery Replacement” for 
complete instructions.
For establishments with multiple Functional Trainer machines, replacement of all 
Power Display batteries at the same time is recommended. 

NOTE: Your Keiser Air Compressor (not included with your Functional Trainer) requires 
basic annual maintenance. For complete Keiser Air Compressor maintenance instructions, 
download the user manual at http://manuals.keiser.com (search “Compressor/Air System”).

Weekly

• 

Hand wash the strap material of accessories using mild detergent (neutral, non-caustic) 
and water. Air dry only.

Contact Keiser Customer Support for replacement parts order, or for any matters regarding the safe operation of your 
Functional Trainer, by telephone at 1 559 256 8000, online 24/7 at keiser.com/support, or by email at [email protected].

CAUTION: THE HIGHEST LEVEL OF EQUIPMENT SAFETY CAN ONLY BE ENSURED IF EQUIPMENT IS 
REGULARLY INSPECTED FOR DAMAGE AND WEAR.

 Always check that the Functional Trainer is securely fastened 

to the Free-standing or Floor Mounted Base before use (no tilt, lean, or any other movement of the unit should be 
detected during use). Immediately replace damaged, worn, or broken parts. Do not use the Functional Trainer until 

all repairs have been completed and tested by a Keiser-certified technician.

IMPORTANT: 

Do not use household or industrial cleaners as they contain caustic chemicals that can destroy the paint 

finish and cause corrosion. Use only 

mild detergent (neutral, non-caustic) to clean. A quat disinfectant cleaner (quaternary 

ammonium chloride) with an anti-microbial agent is acceptable.

Содержание INFINITY 3020XP

Страница 1: ...FUNCTIONAL TRAINER MODEL 3020XP OPERATION MANUAL INFINITY SERIES STRENGTH CARDIO FUNCTIONAL...

Страница 2: ...ENT 15_ANNUAL SERVICING 16 REGULATORY AND COMPLIANCE NOTICES 16 WARRANTY STATEMENT Keiser the Keiser logo and other trademarks associated with Keiser products referred to in this publication are trade...

Страница 3: ...support or by email at service keiser com Yours in Health Keiser Corporation Register your Functional Trainer to stay informed of safety notifications and for faster more accurate warranty service Sca...

Страница 4: ...ccessory during exercise Ensure hook and loop type accessories are fastened firmly before exercise Carefully returntheCableAccessorytothestartpositionbeforegrip is released IMPORTANT SAFETY INFORMATIO...

Страница 5: ...on Ifunreadable or missing contact Keiser Corporation for a replacement by telephone at 1 559 256 8000 online 24 7 at keiser com support or by email at service keiser com SAFETY AND SERIAL NUMBER LABE...

Страница 6: ...cordingly to allow for full range operation When Functional Trainers are placed adjacent to each other the Training Space may be shared Actual Cable Length may vary based on Accessory type user height...

Страница 7: ...justment Knob 13 Accessory Hook 7 Clevis 4 Arm Position Plate 14 9 Instructional Placard Increase Decrease Thumb Buttons 8 Quick Disconnect with Tube 10 OPERATION Free standing Functional Trainer 12 i...

Страница 8: ...OPERATION MANUAL FUNCTIONAL TRAINER 5 8 7 1 3 2 6 4 EXERCISE NUMBER L ADJ POWER DISPLAY Figure 5 Power Display Overview When using the eChip ensure that it is fully inserted into the slot as shown R A...

Страница 9: ...ious corresponding set was a Power Test it displays the resistance to use to achieve maximum power When the calculated resistance to achieve maximum power is being displayed it flashes In summary duri...

Страница 10: ...hold the spring loaded Adjustment Knob 3 Move the Arm to desired position setting 4 Releasethespring loadedAdjustmentKnobatthedesired position setting WARNING Ensure Adjustment Knob is fully engaged...

Страница 11: ...esult in serious injury The Power Test may be performed with or without an eChip To start the Power Test follow the instructions below 1 Press and hold both Thumb Buttons for approximately three secon...

Страница 12: ...NE Consult your physician before beginning any exercise program To help ensure a safe comfortable and effective workout remember to Explosive Hip Flexion Figure 12 Sample Basic Functional Trainer Exer...

Страница 13: ...page 14 Battery Replacement for complete instructions For establishments with multiple Functional Trainer machines replacement of all Power Display batteries at the same time is recommended NOTE Your...

Страница 14: ...ut finger tight 6 IMPORTANT Avoid pinching the Air Line Route the Air Line through the Back Cover notch Reposition the Back Cover onto the Functional Trainer align all screw holes and fasten with the...

Страница 15: ...lean and coat lightly with clean SAE 30 motor oil or with a silicon based spray 5 Replace Air Filter if element is dirty element turns a bright pink or red color Tools required Small Needle Nose Plier...

Страница 16: ...ons However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determin...

Отзывы: