13
OPERATION MANUAL
FUNCTIONAL TRAINER
MAINTENANCE
PREVENTATIVE MAINTENANCE SCHEDULE
Daily
•
Wipe down the external body/parts using a moist cloth and a mild detergent (neutral,
non-caustic). Wipe dry the equipment.
•
Check that parts most susceptible to wear are not damaged or broken:
– Pulleys, Cable, Cable Link, Handle, Thumb Buttons, and Adjustment Plunger.
•
Check to ensure that the Functional Trainer is in safe and proper working order:
–
The Functional Trainer is securely fastened to the base (floor mount or free-
standing). There should be no movement of the unit in any direction during use.
– Press the “+” and then “-” Thumb Buttons a few times to ensure air cycles
through and that the Power Display powers on.
– Cable travels freely and smoothly without binding.
Monthly
•
Inspect Air Line for kinks, tears, or breaks.
•
Clean the external body/parts thoroughly, targeting areas that come in contact with
sweat, using a moist cloth and a mild detergent (neutral, non-caustic). Wipe dry the
equipment.
Quarterly
•
Check mount hardware (wedge anchors) and externally visible screws are fastened with
no looseness. There should be no movement of the unit in any direction during use.
Annually and
other Required
Maintenance
•
For complete instructions, see page 15 “Annual Servicing.”
•
Battery Replacement. The low battery signal (“Lo-bA”) will appear on the Power Display
when it is time to replace the batteries. Refer to page 14 “Battery Replacement” for
complete instructions.
For establishments with multiple Functional Trainer machines, replacement of all
Power Display batteries at the same time is recommended.
NOTE: Your Keiser Air Compressor (not included with your Functional Trainer) requires
basic annual maintenance. For complete Keiser Air Compressor maintenance instructions,
download the user manual at http://manuals.keiser.com (search “Compressor/Air System”).
Weekly
•
Hand wash the strap material of accessories using mild detergent (neutral, non-caustic)
and water. Air dry only.
Contact Keiser Customer Support for replacement parts order, or for any matters regarding the safe operation of your
Functional Trainer, by telephone at 1 559 256 8000, online 24/7 at keiser.com/support, or by email at [email protected].
CAUTION: THE HIGHEST LEVEL OF EQUIPMENT SAFETY CAN ONLY BE ENSURED IF EQUIPMENT IS
REGULARLY INSPECTED FOR DAMAGE AND WEAR.
Always check that the Functional Trainer is securely fastened
to the Free-standing or Floor Mounted Base before use (no tilt, lean, or any other movement of the unit should be
detected during use). Immediately replace damaged, worn, or broken parts. Do not use the Functional Trainer until
all repairs have been completed and tested by a Keiser-certified technician.
IMPORTANT:
Do not use household or industrial cleaners as they contain caustic chemicals that can destroy the paint
finish and cause corrosion. Use only
mild detergent (neutral, non-caustic) to clean. A quat disinfectant cleaner (quaternary
ammonium chloride) with an anti-microbial agent is acceptable.