manualshive.com logo in svg
background image

04

AIR300 LEG PRESS 

OPERATION MANUAL

It is the sole responsibility of the purchaser of Keiser Corporation equipment to instruct all individuals, whether they are the end-
user or supervising personnel, on proper usage of the equipment. Keiser Corporation recommends that all users of its equipment 
be informed of the following information before use.

1.         Read these instructions.
2.  Heed all warnings.
3.  Follow these instructions.
4.  Intended use of the Air300 Leg Press is for physical activity 

or Physiotherapy (sometimes referred to as physical therapy). 

5.  The Air300 Leg Press is intended for individuals aiming to 

maintain and restore maximum movement and functional 
ability throughout their lifespan, including circumstances 
where movement and function are limited by aging, injury, 
pain, disease, disorders, conditions, or environmental factors, 
especially in case of using the Air300 Leg Press in physical 
therapy.

6.  Consult your physician before beginning any exercise 

program.

7.  The Air300 Leg Press is intended for use in training areas 

of organizations where access and control are specifically 

regulated by a person responsible for determining the 
suitability of use and maintenance.

8.  Maximum user weight limit: 441 lbs (200 kg).
9.  Use the Air300 Leg Press indoor in a climate-controlled 

environment only. Keep away from areas of extreme 
humidity.

10.  The use of this Air300 Leg Press for any purpose not 

explicitly specified by the manufacturer in this manual is 

prohibited.

11.  Wear proper exercise clothing and shoes for exercise. Avoid 

wearing loose clothing that might catch on any moving parts. 
Tie long hair back.

12.  The Air300 Leg Press is not a toy. Children shall not play with 

the Air300 Leg Press. Children under 14 years old should 
not use the Air300 Leg Press. Keep children and pets clear 
from the Air300 Leg Press at all times, especially while in 
use. Cleaning and user maintenance shall not be performed 
by children.

13.  The Air300 Leg Press can be used by children age 14 years 

and above. Persons with mental disabilities, reduced physical, 
mental, or sensory capabilities, or lack of experience or 
knowledge should not use the Air300 Leg Press without 
constant supervision by a spotter/supervisor.

14. 

Do not increase resistance during extension/flexion. Avoid 

locking knees. Serious physical injury can result. Holding 
capacity of locked knee joints is higher than the legs can 
support during return.

15.  Proper warm-up required to help prevent injury. This Air300 

Leg Press should only be used with proper instructions. 
Always maintain good form and control during exercise. 
If you feel pain or are unable to maintain good form, stop 
immediately. Failure to follow these instructions could result 
in injury.

16.  Always keep feet on Foot Pads during exercise. The sudden 

release of the Foot Pads during exercise will cause the Foot 
Pads to recoil toward the user and could result in serious 

injury or property damage. Extend the Foot Pads and 
engage the Movable Stops to safely exit the equipment. 
If at any time you are not able to extend your legs during 
exercise, push the left (“-”)Thumb Button to reduce the 
resistance.

17.  Never perform Power Test without a proper warm-up. This 

high resistance/high-speed test should only be performed 
with proper instructions (see page 15 “Power Test”

 

for 

complete instruction). Always maintain good form and 
control during the test. If you feel pain or are unable to 
maintain good form, stop immediately. Failure to follow 
these instructions could result in injury.

18.  Never make adjustments to the machine during exercise as 

this may cause muscle strain. Always return the Exercise 
Arm to the start position before making any adjustments 
to help prevent injury.

19.  The highest level of safety can only be ensured if the 

equipment is regularly inspected for damage and wear. 
Always check the equipment before use for proper function 
and any damaged, worn, or broken parts. Immediately 
replace damaged, worn, or broken parts. Do not use the 
Air300 Leg Press until all repairs have been completed and 

tested by a Keiser-certified technician.

20.  Use only replacement parts supplied/recommended 

by Keiser Corporation. Attempting to repair or replace 
any damaged, worn, or broken parts on your own is not 

recommended.  A  Keiser-certified  technician  should  be 

consulted.

21.  The use of any exercise equipment, including, without 

limitation, Keiser’s strength training equipment in which 
resistance can be changed at any time during the repetition, 
without proper instruction and supervision violates the 
terms of the agreement for the purchase of such products. 
The ability to add resistance anytime during a repetition, 
including, without limitation, the ability to do a heavy 
negative may be dangerous, especially for anyone that 
does not recognize or respect the potential danger.

22.  Users, agents, and/or anyone directing the use of the Air300 

Leg Press shall determine the suitability of the Air300 Leg 

Press for its intended use, and said parties are specifically 

put on notice that they shall assume all risk and liability in 
connection herewith.

23.  If you do not understand these instructions or have doubts 

about the safety of the installation, assembly, or use of this 
product, contact Keiser Customer Support:

1 559 256 8000

[email protected]

keiser.com/support

Telephone and Live Chat
Monday—Friday 7 am to 5:30 pm PST

IMPORTANT SAFETY INFORMATION

Содержание 002531BP

Страница 1: ...LEG PRESS MODELS 002531BP 002531SP OPERATION MANUAL AIR300 STRENGTH CARDIO FUNCTIONAL...

Страница 2: ...E 19 REGULATORY AND COMPLIANCE NOTICES 19_SAFETY NOTIFICATIONS 20_ELECTROMAGNETIC COMPATIBILITY EMC 20_US FCC COMPLIANCE STATEMENT 20_DISPOSAL 23 WARRANTY STATEMENT Keiser the Keiser logo and other tr...

Страница 3: ...y notifications and for faster more accurate warranty service Scan the QR Code to the right to access the interactive online warranty registration form or visit https www keiser com forms warrantyregi...

Страница 4: ...el pain or are unable to maintain good form stop immediately Failuretofollowtheseinstructionscouldresult in injury 16 AlwayskeepfeetonFootPadsduringexercise Thesudden releaseoftheFootPadsduringexercis...

Страница 5: ...hat if not avoided could result in minor or moderate injury IMPORTANT Indicates information considered critical but not hazard related IMPORTANT SAFETY INFORMATION Maintain and do not remove safety or...

Страница 6: ...thmias at rest or aortic aneurysm If the patient is experiencing acute illness febrile condition i e fever or newly occurring pain this represents an absolute contraindication for physical stress In s...

Страница 7: ...accumulator with the following operating parameters POWER 1 5V D Alkaline Batteries quantity 2 Keiser PN 966500 3V CR2032 Lithium Coin Cell Battery quantity 1 Permanently attached not serviceable Con...

Страница 8: ...p to a minimum of 100 psi 6 89 bar Keiser Compressor and Keiser Air System not included sold separately 2 Connect the 1 4 inch Quick Disconnect QD from the equipment to an Outlet in the Keiser Air Sys...

Страница 9: ...e 6 Instruction Placards not shown 17 18 Exercise Arms 3 Air Tubes and Communication Wires 13 Seat Track and Position Settings 14 Air Tanks 7 Lock Bar 4 Increase Decrease Thumb Buttons 15 10 Stop Rele...

Страница 10: ...deletes the current workout data from the eChip System Messages appear in the RESISTANCE window OFF low power consumption sleep mode Sleep mode occurs after 60 seconds of machine inactivity to help pr...

Страница 11: ...a indicates no data was input to record Settings can only be changed immediately after the eChip is inserted and before your third rep After three reps are performed the setting cannot be changed unti...

Страница 12: ...Upholstery no excessive wear free of rips or tears C Thumb Buttons and Display press Thumb Buttons to check for proper operation power on the Display D Seat Seat Lever allows the Seat to slide freely...

Страница 13: ...Movable Stops are set below the dots 1 2 3 4 5 BEFORE ENTERING THE MACHINE Set the Lock Bar to exercise one leg at a time or both together Lift the Seat Lever to adjust the Seat and comfortably enter...

Страница 14: ...old the Stop Release Bars on both sides Extend the legs fully and at the same level without locking the knees keep a slight bend in the knees Maintain erect position on the Seat and Seat Back ECCENTRI...

Страница 15: ...high speed 80 90 of your maximum SET 2 Three repetitions Low resistance high speed 10 of your maximum SET 1 START TEST Press and hold both Thumb Buttons release when 6 r appears in the RESISTANCE wind...

Страница 16: ...tions NOTE Your Keiser Air Compressor not included with your Air300 Leg Press requires basic annual maintenance Contact Keiser Customer Support for Air Compressor operator manual or download at keiser...

Страница 17: ...g inside the battery compartment insert the 2 new D batteries into the battery sleeve and install The Power Display will enter a brief test sequence youwillseeaseriesofnumbers flashing 4 Replace the P...

Страница 18: ...ubricate Cylinder Rods Wipe the Cylinder Rods clean and coat lightly with clean SAE 30 motor oil or with a silicon based spray 5 Replace the Mufflers one on each Cylinder if discoloration is present T...

Страница 19: ...with the disposal of waste products residues including disposal of the equipment itself at the end of its useful life The Air300 Leg Press contains electronic circuit assemblies 2 alkaline D cell batt...

Страница 20: ...TROMAGNETIC COMPATIBILITY EMC DISPOSAL This equipment contains electrical or electronic components alkaline batteries and a sealed lithium coin cell battery that must be disposed of properly to comply...

Страница 21: ...21 AIR300 LEG PRESS OPERATION MANUAL This page intentionally left blank...

Страница 22: ...22 AIR300 LEG PRESS OPERATION MANUAL This page intentionally left blank...

Страница 23: ...ay 7 am to 5 30 pm PST or by email at service keiser com Customers outside the United States may obtain warranty information directly through a Keiser international distributor or dealer in the countr...

Страница 24: ...after reading this manual contact Keiser Customer Support 255501_D 1 559 256 8000 service keiser com keiser com support Telephone and Live Chat Monday Friday 7 am to 5 30 pm PST 24 AIR300 LEG PRESS OP...

Отзывы: