manualshive.com logo in svg
background image

OPERATION MANUAL

AIR350

STRENGTH

 

|

 CARDIO 

|

 FUNCTIONAL

BIAXIAL CHEST PRESS

MODELS: 001335BP, 001335XP

Содержание 001335BP

Страница 1: ...OPERATION MANUAL AIR350 STRENGTH CARDIO FUNCTIONAL BIAXIAL CHEST PRESS MODELS 001335BP 001335XP...

Страница 2: ...MAINTENANCE 19 REGULATORY AND COMPLIANCE NOTICES 19_SAFETY NOTIFICATIONS 20_ELECTROMAGNETIC COMPATIBILITY EMC 20_US FCC COMPLIANCE STATEMENT 20_DISPOSAL 23 WARRANTY STATEMENT Keiser the Keiser logo an...

Страница 3: ...to stay informed of safety notifications and for faster more accurate warranty service Scan the QR Code to the right to access the interactive online warranty registration form or visit https www keis...

Страница 4: ...follow these instructions could result in injury 15 Always maintain control of the Handles Exercise Arms duringexercise ThesuddenreleaseoftheExerciseArms during exercise will cause the Exercise Arms...

Страница 5: ...tion that if not avoided could result in minor or moderate injury IMPORTANT Indicates information considered critical but not hazard related IMPORTANT SAFETY INFORMATION Maintain and do not remove saf...

Страница 6: ...ngerous heart arrhythmias at rest or aortic aneurysm If the patient is experiencing acute illness febrile condition i e fever or newly occurring pain this represents an absolute contraindication for p...

Страница 7: ...L EQUIPMENT SPECIFICATIONS 78 inches 1 981 mm 58 inches 1 473 mm 43 inches 1 092 mm 194 lbs 88 kg Figure 2 Air350 Biaxial Chest Press Equipment Specifications See Figure 2 for Air350 Biaxial Chest Pr...

Страница 8: ...AIR SYSTEM WARNING Never connect equipment to an air source capable of exceeding 120 psi 8 27 bar Over pressurizing Keiser pneumatic equipment may cause tubing to burst breakage of equipment abnormal...

Страница 9: ...iaxial Chest Press Increase Decrease Thumb Buttons Quick Disconnect QD with Tube Power Display Exercise Arms Seat Back Instruction Placard not shown Adjustable Seat Air Tank Arm Adjustment Plunger Kno...

Страница 10: ...also deletes the current workout data from the eChip System Messages appear in the RESISTANCE window OFF low power consumption sleep mode Sleep mode occurs after 60 seconds of machine inactivity to he...

Страница 11: ...t data indicates no data was input to record Settings can only be changed immediately after the eChip is inserted and before your third rep After three reps are performed the setting cannot be changed...

Страница 12: ...Power Display remains blank see Battery Replacement procedure page 17 A Thumb Buttons and Display press Thumb Buttons to check for proper operation and the Display powers on B Exercise Arms move freel...

Страница 13: ...line with the middle of your chest and your feet rest flat on the floor 2 Adjust the Arm position to accommodate your desired range of motion 3 Adjust the resistance with the Thumb Buttons 1 2 3 Figu...

Страница 14: ...xercise Arms are set symmetrically Extend push arms forward at the same time and without locking your elbows move arms at the same level Maintain an upright position with your back in contact with the...

Страница 15: ...ance high speed 80 90 of your maximum SET 2 Three repetitions Low resistance high speed 10 of your maximum SET 1 START TEST Press and hold both Thumb Buttons release when 6 r appears in the RESISTANCE...

Страница 16: ...E Your Keiser Air Compressor not included with your Air350 Biaxial Chest Press requires basic annual maintenance Contact Keiser Customer Support for Air Compressor operator manual or download at keise...

Страница 17: ...artment insert the 2 new D batteries into the battery sleeve and install The Power Display will enter a brief test sequence youwillseeaseriesofnumbers flashing 4 Replace the Processor Box cover and sc...

Страница 18: ...s dirty element turns a bright pink or red color Tools required Small Needle Nose Pliers Cutter Tool to cut off flared end of tubes 6 Lubricate Cylinder Rods Wipe the Cylinder Rods clean and coat ligh...

Страница 19: ...ssociated with the disposal of waste products residues including disposal of the equipment itself at the end of its useful life The Air350 Biaxial Chest Press contains electronic circuit assemblies 2...

Страница 20: ...ELECTROMAGNETIC COMPATIBILITY EMC DISPOSAL This equipment contains electrical or electronic components alkaline batteries and a sealed lithium coin cell battery that must be disposed of properly to c...

Страница 21: ...AIR350 BIAXIAL CHEST PRESS OPERATION MANUAL 21 This page intentionally left blank...

Страница 22: ...AIR350 BIAXIAL CHEST PRESS OPERATION MANUAL 22 This page intentionally left blank...

Страница 23: ...onday Friday 7 am to 5 30 pm PST or by email at service keiser com Customers outside the United States may obtain warranty information directly through a Keiser international distributor or dealer in...

Страница 24: ...after reading this manual contact Keiser Customer Support 135501_C 1 559 256 8000 service keiser com keiser com support Telephone and Live Chat Monday Friday 7 am to 5 30 pm PST AIR350 BIAXIAL CHEST P...

Отзывы: