SLEEP MODE 

The RAPT Pill Hydrometer will enter sleep mode when the device is in a horizontal orientation. It will 
automatically wake up when its orientation is changed indicated by the illumination of a green light 
on the circuit board. 

When not in use ensure the RAPT pill hydrometer is in a horizontal orientation to ensure it remains 
asleep. 

OPERATION INSTRUCTIONS 

Your RAPT Pill Hydrometer comes pre-calibrated and ready to go after charging, assembly and device 
registration. For calibration steps refer to the 

Calibration

 section below. 

 

1.

 

Submerge your RAPT Pill hydrometer in a glass of pint water to test for leaks prior to placing 
into your fermenter. 

2.

 

Sanitise your RAPT Pill Hydrometer with an approved sanitiser such as 

StellarSan

 or 

Phosphoric Acid

 which has been correctly diluted according to the instructions on the 

sanitiser’s container.

 

3.

 

Drop your RAPT Pill Hydrometer into your fermenter to monitor the specific gravity and 
temperature of your brew in real time which is relayed to the RAPT portal for logging. 

 

 

 

Содержание RAPT KL20596

Страница 1: ...RAPT Pill Hydrometer Thermometer Quick Start Guide Page 1 of 10 www KegLand com au Last Updated 1 12 2021 12 53 PM Pill Hydrometer Thermometer KL20596 Quick Start Guide KegLand Distribution PTY LTD...

Страница 2: ...ts the battery from completing a connection and draining during shipping Battery Installation If required Only use KegLand approved 18650 rechargeable Lithium ion batteries KL26734 The RAPT Pill Hydro...

Страница 3: ...lid Red Charging No Light Fully Charged ESP LED Flashing Green sending or receiving data telemetry SIGN UP FOR A RAPT ACCOUNT To utilise the Wi Fi connectivity of the RAPT Pill Hydrometer you will nee...

Страница 4: ...ically open a browser to the Pill Captive Portal 3 Select your Wifi access point enter your password and select Join 4 Once you have joined click on the Registration link to see your MAC address Write...

Страница 5: ...using it is important to insert the circuit board in the correct orientation to ensure the correct weight distribution for accurate readings The yellow end of the circuit board should be inserted into...

Страница 6: ...STRUCTIONS Your RAPT Pill Hydrometer comes pre calibrated and ready to go after charging assembly and device registration For calibration steps refer to the Calibration section below 1 Submerge your R...

Страница 7: ...ng the Calibration process with prevent this from occurring Hence keeping both the Calibration and Diagnostic screens open allows you to easily calibrate the RAPT Pill without losing connection to the...

Страница 8: ...t does not matter if the gravity readings are not exactly 10 points apart as long as the gravity reading is correct Use of a hydrometer that is known to be accurate is quite important To perform the r...

Страница 9: ...this y 0 0000023109x5 0 0005741632x4 0 0568746764x3 2 8119846525x2 71 1087310405x 265 6578215178 This is a sample only DO NOT USE THIS EQUATION AS IT WILL NOT BE ACCURATE Substitute x in this equatio...

Страница 10: ...or support on how to use your RAPT Pill Hydrometer Thermometer or the RAPT Portal If you need hardware support please contact your nearest distributor The RAPT Pill Hydrometer Thermometer comes with a...

Отзывы: