background image

UK: +44 (0) 1753-857177 • USA: 1-800-523-5620 • 

keeler.co.uk 

• 

keelerusa.com

14

Troubleshooting

Refer to table 4.1 for information on identifying and correcting problems that can occur 

with the PachPen.

Table 4.1 - PachPen troubleshooting information

Symptom

Probable cause

Correction

“LOW BATT” displayed

Battery is low

Replace battery (see Chapter 3)

Multiple variable readings Improper technique

Review measurement technique

Battery is low

Replace battery (see Chapter 3)

Mechanical or electronic 
damage

Arrange for repair through Keeler 
technical service group (see Chapter 6)

No beep and/or no 
display upon activation

Action control button not 
held down long enough

Hold down action control button longer

Incorrect battery 
installation

Check battery installation

Battery is low

Replace battery (see Chapter 3)

Mechanical or electronic 
damage

Arrange for repair through Keeler 
technical service group (see Chapter 6)

No readings

Improper technique

Review measurement technique

Incorrect battery
installation

Check battery installation

Battery is low

Replace battery (see Chapter 3)

Mechanical or electronic 
damage

Arrange for repair through Keeler 
technical service group (see Chapter 6)

Maintenance, storage, & troubleshooting

Содержание PachPen IFU-24-5100

Страница 1: ...PachPen User s guide IFU 24 5100 REV C...

Страница 2: ...ce to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reori...

Страница 3: ...on of the probe 6 Warnings 6 Electrical hazard and safety 6 Avoiding equipment damage 6 Avoiding electromagnetic and other interference 7 Chapter 3 Getting started 8 Overview 8 Unpacking instructions...

Страница 4: ...Specifications 15 Overview 15 Physical specifications 15 Environmental specifications 15 Measurement accuracy 16 Operating modes 16 Acoustic output 17 Chapter 6 Warranty repairs 19 Warranty 19 Produc...

Страница 5: ...Figure 3 7 True IOP screen 11 Table 3 1 IOP correction values 12 Table 4 1 PachPen troubleshooting information 14 Table 5 1 PachPen physical specifications 15 Table 5 2 Environmental specifications 1...

Страница 6: ...tware protects your investment The PachPen provides the following general features Multi segmented high resolution LCD screen with control buttons to provide an intuitive user interface Long lasting l...

Страница 7: ...trists and ophthalmologists who are experienced in corneal thickness measurement techniques This manual is organized as follows Chapter 2 Safety Summarizes safety precautions warnings symbols and term...

Страница 8: ...t companies can provide assistance in the disposal of these cells and batteries 2 Disposal should be done in accordance with applicable regulations which vary from country to country In most countries...

Страница 9: ...harged are considered as reactive hazardous waste Thus hazardous waste of spent cells and batteries can be disposed of after they are first neutralized through an approved secondary treatment prior to...

Страница 10: ...products and procedures are effective and appropriate for ophthalmic applications The following information is provided for the guidance of users and specific products are mentioned for illustration o...

Страница 11: ...an electrical connection and handling electrically powered devices Avoid the use of damaged electrical equipment If repair or maintenance is to be performed on the PachPen the equipment must be turne...

Страница 12: ...phone or other device not compliant with EMC Class B requirements as its signals may cause the equipment to malfunction The effect of radio signals on medical devices is dependent on various factors a...

Страница 13: ...rep pads Note Notify Keeler immediately if any components are missing or damaged See Chapter 6 of this user guide for contact information Battery specification and installation The power source for th...

Страница 14: ...in a closed position Do not over tighten the screw Instructions for use Initial PachPen pachymeter setup The following steps outline the basic setup of the PachPen 1 If the battery is not installed in...

Страница 15: ...displayed How to start a new patient 1 Hold the up and down control buttons on the PachPen simultaneously for 2 to 3 seconds 2 A single beep from the instrument will indicate that all measurements av...

Страница 16: ...down control button for several seconds until the unit emits a high pitched chirp After deleting a measurement the unit will automatically recalculate the average of the measurements How to perform a...

Страница 17: ...rs Correction values mmHg 405 7 425 6 445 5 465 4 485 3 505 2 525 1 545 0 565 1 585 2 605 3 625 4 645 5 665 6 685 7 705 8 Correction values according to corneal thickness of 545 micrometers These corr...

Страница 18: ...ping everything except the tip with a clean lint free non abrasive cloth and alcohol Clean the PachPen pachymeter tip by dipping only the first inch of the tip into alcohol or in an ultrasonic cleaner...

Страница 19: ...repair through Keeler technical service group see Chapter 6 No beep and or no display upon activation Action control button not held down long enough Hold down action control button longer Incorrect b...

Страница 20: ...en physical specifications Main unit Dimensions 18 4 cm X 3 2 cm X 3 2 cm 7 25 X 1 25 X 1 25 Weight 85 g 3 oz Display Type Multi segment monochrome liquid crystal display LCD Size 28 6 mm 1 13 diagona...

Страница 21: ...icrometers Electronic Resolution 1640 m sec 1 Micrometer Range 300 999 Micrometers Operating modes The table 5 4 summarizes the mode application possibilities for each system transducer combination Ta...

Страница 22: ...ing control conditions Table 5 6 Guidance and manufacturer s declaration electromagnetic emissions The PachPen is intended for use in the electromagnetic environment specified below The customer or th...

Страница 23: ...is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transm...

Страница 24: ...teration repair or modification of any product that is performed by persons not authorized by Keeler will immediately void the warranty Product returns Follow the instructions given below to return pr...

Страница 25: ...andise held longer than 30 days Replacement parts Table 6 1 below lists items that are available from Keeler or from your local sales representative Please be sure to use the Keeler part number for th...

Страница 26: ...Effective date November 8 2022 keeler co uk keelerusa com Contact us UK 44 0 1753 857177 USA 1 800 523 5620 India 91 99 3031 1090 Brazil 55 11 4302 6053 China 86 18512119109...

Отзывы: