1.Decide where the mineral woll sealing is to be
pplaced in the chimney. If nessecery, clean the inside
of the stove from soot or any loose mortar using a
steelbrush.
Measure the distance from the connection hole in
the insert to the sealing point in the existing chimney.
Apply the mineral wool immediaetly under the top
sleeve of the steel pipe with steelwire. Push the pres
-
sure ring on to the pipe so that it just makes contact
with the mineral wool.
2. Assemble the pipes needed to reach the wool
sealing point with heat resistant sealant to ensure no
leaks in the joints.
In the case of a 45 degree smoke outlet (standard)
adjust the support leg to 45 degree angle and screw
it to the pipes 60 mm from the lower end of the pipes.
In case of a 90 degree smoke outlet (Accessory)
adjust the support leg to 90 degrees and screw it in
alignment with the underside of the pipes. Move the
protection rod from the 45 degree smoke outlet to the
90 degree smoke outlet.
3. Use the supportleg to insert the pipes into the fire
-
place. Push the pressure ring upwards to expand the
insulation against the chimney walls.
Ensure that the insulation seals tightly against
the chimney walls to prevent heatloss through
the chimney. If nessesary add mineral woll insula
-
tion achieve a tight seal.
Important! Do not fix the pipes with putty or any
kind of mortar as this can cause cracks to the
chimney.
Apply the combustion air pipe to the steel pipes with
sealent.
INSTALLATION GUIDE ALT. 1
- 6 -
In order to follow installation guide 1 the assesorie ”installation kit” is needed. If you find that the
insert is to heavy to transport to the installation site it is easy to disassemble the body from the front/
door section of the insert. This is described later in the manual.