TECHNICAL SPECIFICATIONS

SK1000

Height 

  470-475 

mm

Width 

  500 

mm

Depth 

  400 

mm

Weight 

 

100 kg

Flue pipe diameter  125 mm

Efficency        

82%

Output 

 

4-9 kw

SK2000

Height 

  535-540 

mm

Width 

  600 

mm

Depth 

  500 

mm

Weight 

 

125 kg

Flue pipe diameter  125 mm

Efficency        

82%

Output 

 

5-10 kw

Содержание SK1000

Страница 1: ...Fireplace inserts Installation instructions Care and firing instructions Model SK1000 SK2000...

Страница 2: ...MATION 3 IMPORTANT POINTS 3 PRECONDITIONS 4 Building notice Flue Combustion air Standard delivery Exploded diagram PREPARATIONS 5 INSTALLATION INSTRUCTIONS 6 8 CARE FIRING INSTRUCTIONS 9 10 TECHNICAL...

Страница 3: ...been manufactured in accordance with the documents that form the basis for the respective certificates and their associated requirements for production inspections IMPORTANT POINTS Contact the Plannin...

Страница 4: ...occur in houses with mechanical ventilation This is not normally necessary for a fireplace insert as it is installed in an existing open fireplace which is designed to work in the house atmosphere A...

Страница 5: ...l installations of Keddy s fire place inserts with this parameter fulfilled Since existing open fireplaces vary in design this should be considered as an installation guide and we will discuss two ins...

Страница 6: ...sory adjust the support leg to 90 degrees and screw it in alignment with the underside of the pipes Move the protection rod from the 45 degree smoke outlet to the 90 degree smoke outlet 3 Use the supp...

Страница 7: ...e protective iron rod and pull it into position enabling you to fit the two screws Once again check that the insert is level 6 If nessesary assemble the front door to the insert body Be very careful t...

Страница 8: ...you want to insulate it against the existing chimney with mineral wool Ensure that the insulation seals tightly against the existing chimney and that it is level with the upper edge of the pipe so no...

Страница 9: ...RE FIRING WHEN THE FIREPLACE IN SERT IS NEW During the first week firing can be started carefully Begin with one or two fires a day with half of the fol lowing prescribed amount of wood A particular s...

Страница 10: ...te the downdraught and avoid the nuisance of smoke enter ing the room in the initial stage If the premises are equipped with mechanical venti lation i e if there are one or more fans to evacuate the a...

Страница 11: ...00 Height 470 475 mm Width 500 mm Depth 400 mm Weight 100 kg Flue pipe diameter 125 mm Efficency 82 Output 4 9 kw SK2000 Height 535 540 mm Width 600 mm Depth 500 mm Weight 125 kg Flue pipe diameter 12...

Страница 12: ...www keddy se Keddy AB Box 542 441 15 ALINGS S Tel 46 0 322 781 80 Fax 46 0 322 781 89 E mail info keddy se Website www keddy se Rev 1 01 09 2013...

Отзывы: