background image

z

 

When the battery runs out: at this time, the “

” icon will continuously appear on LCD to 

remind you to replace the battery.   

                                                                                                                               

 

z

 

When the measured distance is out of the specified range: the effective range is 2

~53

 (0.5~16m).                           

                                                                                                                               

 

z

 

When the calculated result is out of the specified range: at this time, an error message “Err” will 

be displayed on the lower line of the screen. 

   

z

 

When addition of different parameters (e.g. length plus area), the “+” will be ignored and the 

screen will keep the same read as the unit was operated before. 

z

 

When another ultrasonic source or high frequency noise is nearby: leave or shut down the noise 

resource when taking measurement. 

z

 

When barriers appear between the tool and the measured surface. 

z

 

When the measured surface is not smooth: the measured surface should be smooth, hard and of 

homogeneity. 

z

 

When the measuring environment is not good: the temperature and humidity will affect the 

accuracy of measurement, and take measurement under environment of no wind, and temperature 

of the unit should be same with temperature of the circumstance, especially for long distance 

measuring (between 40’ to 53’/ 12m to 16m), the relative humidity should be above 48%, and the 

size of measured surface should be at least 10ft. by 10ft./3m by 3m. 

z

 

When measuring, ultrasonic sensor aperture should straightly face to the measured surface. 

Cautions 

z

 

Handle with care and do not let the tool drop down. 

z

 

Do not disassemble the tool to avoid failure. 

z

 

Keep the tool dry and clean. 

z

 

Store the tool in a box when not in use. 

z

 

Avoid dust and water, which may stain the lens. 

z

 

Check battery regularly to avoid deterioration. 

z

 

Remove the battery when not in use for an extended period of time. 

11 

Содержание KC-200

Страница 1: ...Bidirectional Ultrasonic Distance Measurement Model KC 200 Operation Manual ...

Страница 2: ...low the instructions listed below may cause personal injury z Read and understand all instructions prior to any operation z Do not remove any labels from the tool z Do not operate the tool with the presence of flammable explosive gases z Do not operate the laser tool around the children or allow children to operate the laser tool failure to do so will injure eyes of children z Do not stare into th...

Страница 3: ... B Laser pointer C Two row LCD the data of upper line is the current measuring result and the data of lower line is the memory computing result D BASE key measurement base selection key Keep pressing this key for 2s to shut the tool E M key memory function key memory the measurement result F MODE key mode transform key Three circulation transform patterns The length area volume and the default sta...

Страница 4: ...ment and close the door Distance measurement z Make the induction hole of the tool face against the measured object e g the wall and keep the tool vertical to the measured object make sure the point of the level vial stands between the two lines of the level vial by adjusting the position of the unit z Press the READ key to start the tool the instrument is ready to work z Press the READ key again ...

Страница 5: ...tool And if there s no action in 60s the tool will turn off automatically Tips A The measured object must be a normative horniness surface and without barrier B To ensure exact measurement the measured surface should be smooth bigger area and of homogeneity C If the measured surface is too small abnormity or the surface is soft a board should be placed on the surface of measured object D The unit ...

Страница 6: ...the new sum on the lower portion of the screen Note If continuously press the key for 2 times the addition operation will be canceled all the anterior computation result will clear away z Repeat the steps 3 4 above can continue accumulation Addition using M memory z Press the M key to save the first measured result and the M will appear on the right portion of the screen z Press the READ key for n...

Страница 7: ...sing M key again the tool will memory the result on the bottom of the display The tool will add with accumulation Area z Press MODE key to enter area mode and the will appear on the display z The length character on the display will blink with the frequency of 2Hz showing the length measurement you will be firstly taking Press READ key to take length measurement and display on the screen Step 1 z ...

Страница 8: ... on the portion of the screen then can begin the new calculation of area Addition of area under area mode z Press the M key to save the calculated area on the lower portion of the screen at the same time the M icon appears on the screen z Press MODE key again to begin the second time measurement and computation follow step 1 2 and 3 under the area section z After getting the desired area of the se...

Страница 9: ... screen z Repeat the steps above to keep adding the measured area z Repeat the steps 1 5 above can continue accumulation Volume z Press MODE key to enter volume mode and the will appear on the display z The length character on the screen will blink with the frequency of 2Hz showing length measurement will be taking Press READ key to take length measurement the result will be displayed on the scree...

Страница 10: ...th and width height volume measurement result and corresponding icon and will display and blink with the frequency of 2Hz on the screen meanwhile the measurement won t work z Press MODE key to clear the data on the screen and then can begin the new calculation of volume Addition of volumes under volume mode z Press M key to save the calculated volume on the lower portion of the screen and the M ic...

Страница 11: ...s is shown on the lower portion of the screen z Repeat the steps 1 5 above can continue accumulation Temperature display Press and hold MODE key for 2 seconds the environment temperature will appear on the lower portion of screen the unit is if the distance unit is M while the unit is if the distance unit is ft in and press the READ key again to return the measuring state OPERATION INSTRUCTION If ...

Страница 12: ...ot smooth the measured surface should be smooth hard and of homogeneity z When the measuring environment is not good the temperature and humidity will affect the accuracy of measurement and take measurement under environment of no wind and temperature of the unit should be same with temperature of the circumstance especially for long distance measuring between 40 to 53 12m to 16m the relative humi...

Страница 13: ...econds press any key to start the backlight Automatic off The tool will be automatically off if there s no action 60 seconds Power supply One 9V battery Power consumption 80mA Operating temperature 0 to 40 Operating humidity 30 70 RH Storage environment 20 60 85 w o battery Size 180mm 82mm 49mm Weight About 190g battery not included WARRANTY The product is warranted to be free from defects in mate...

Отзывы: