background image

                                                                                                                                           

 

 Press MODE key to clear the current displayed data, then can begin the second time measurement and 

computation (Follow step 1 to 3 under the volume section);                            

 

 After getting the calculated volume of second time, press +/= key to enter the addition mode. A “+” 

icon would appear on LCD;                               

                                                                                                                                           

 

 Press RM key to recall the first calculated volume for the addition. The “M+” icon will disappear and 

the stored memory will be automatically cleared; 

 

 

 Press +/= key, the sum of both volumes is shown on the lower portion of the screen;     

                                                                                                                                           

 

 Repeat the steps above to keep adding the measured volume. 

 

8

Temperature display 

Press and hold MODE key and at the same time press the RM key, the environment temperature will 

appear on the lower portion of screen (the unit is 

 if the distance unit is M, while the unit is 

 if the 

distance unit is ft/in), and press the READ key again to return the measuring state.     

                               

 

 

Stud detect 

Press the “k” button to the "DETECTOR" location, the tool will enter detection state and wait to detect. 

1

 

Calibration 

The tool should be calibrated on the surface of the detected object before detecting or after 

function “D” switch’s diversion.

 

10 

Содержание KC-109A

Страница 1: ...5 in 1 Multifunction Gauge Model KC 109A Operation Manual ...

Страница 2: ...surface through the marker slot on top of the tool with pencil The function of alarming for AC live wires will duly remind you of noticing whether there are AC live wires behind the wall no matter functional switch is set on joists or metal Laser mark function The tool can generate a visible red laser line on the surface of objects It is convenient for you to choose the desired position while cons...

Страница 3: ...m Do not stare into beam Avoid direct eye exposure This tool emits a laser radiation Battery Safety Instructions Please remove the batteries when clean the product Remove the batteries before long term storage Please install the batteries properly as the instructions of the positive and negative charges Please dispose the batteries properly High temperature will cause explosions and do not burn th...

Страница 4: ...sor aperture J Laser pointer K Function switch Select mode for laser mark distance measure or detection L Level vials M M Memory input key Input the length area or volume into memory N Pin button Can fix the tool while laser marking O MODE Clear Mode select Press this key to clear or return back to the menu to select length area or volume mode ILLUSTRATION OF DISPLAY SCREEN A Plus B Length Area vo...

Страница 5: ...re 1 Distance measurement Make the induction hole I face against the measured object e g the wall and keep the tool vertical to the measured object make sure the level bubble stands between the two lines by adjusting the position of the tool Press the READ key to get the measured distance and the laser beam indicates the measured surface Keep pressing the READ key and move the tool to get the dyna...

Страница 6: ...he unit was operated before e When another ultrasonic source or high frequency noise is nearby leave or shut down the noise resource when taking measurement f When barriers appear between the tool and the measured surface g When the measured surface is not smooth the measured surface should be smooth hard and of homogeneity h When the measuring environment is not good the temperature and humidity ...

Страница 7: ...cumstance G The distance measurement should be counted from the end of the tool 2 Addition W O using M memory Press READ key for measurement and the measured value is displayed on upper portion of the screen Press key to enter the addition mode and the icon will appear on the display and at the same time the result is displayed on the lower side of the display press key again to cancel the add ope...

Страница 8: ...is shown on the lower portion of the screen 4 Area Press MODE key to enter area mode and the will appear on the display for calculation of a room area The length character L on the display will blink showing the length measurement you will be firstly taking Press READ key to take length measurement that is displayed on upper portion of the screen Step 1 The width character W on the display will bl...

Страница 9: ... MODE key will clear the current datum and the mode will be invariable 5 Addition of area under area mode Press the M key to save the calculated area of first time measurement at the same time the M icon appears on the screen Press MODE key to clear the current displayed data then can begin the second time measurement and computation follow step 1 and step 2 under the area section After getting th...

Страница 10: ...key to take height measurement the result will be displayed on upper portion of screen Step 3 Then the volume is automatically displayed on the lower portion of the screen Pressing the READ key again will toggle back and forth between the length width and height measurement on the upper portion of the screen Press MODE key to clear the data on the portion of the screen and then can begin the new c...

Страница 11: ...s shown on the lower portion of the screen Repeat the steps above to keep adding the measured volume 8 Temperature display Press and hold MODE key and at the same time press the RM key the environment temperature will appear on the lower portion of screen the unit is if the distance unit is M while the unit is if the distance unit is ft in and press the READ key again to return the measuring state...

Страница 12: ...hen calibrating the tool will automatically set the degree of induction according to the distance to the live wire If distance to the AC live wire is far enough the induction will be set to the strongest degree if close to the AC live wire the tool will automatically set to the most ideal induction according to the distance Detecting calibration for metal objects Set the mode switch to the mode fo...

Страница 13: ...sly you must restart the calibration and repeat the steps above to detect AC live wire detection detecting the AC live wire through walls a According to the calibration requirements for AC live wire detection calibrate the tool to the ideal induction b Operate the tool and find out the two edges of AC live wires and make a mark with reference to the method of Joist detection detecting joists throu...

Страница 14: ...mbol will blink continuously on the screen after calibration Replace with new battery according to instructions b In order to make sure that the scanner is on the best state during detection hold the tail of the tool when operation and keep the other hand at least 6 inches away from the tool during detection Laser marking function Press the K button to the LASER location the tool will enter laser ...

Страница 15: ...on of the baseline on any other surfaces cannot be used as a reference If the laser line is not visible during operation please check and replace the battery The tool is recommended for indoor use The visibility of the laser will be affected if the tool is used outdoor Cautions Operate with care and do not let the tool drop down Do not disassemble the tool in case of damage Keep the tool dry and c...

Страница 16: ...y from the wall Power supply One 9V battery Power consumption 50mA Operating temperature 5 40 Operating humidity 30 70 Storage environment 20 60 85 w o battery Size 170mm 85mm 45mm Weight About 230 g battery not included WARRANTY The product is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase on the basis of providing relevant card N...