21 Appendix: KVC telegrams on KeTop T10
This appendix explains how the KeTop T10 executes the KVC telegrams. Fur-
thermore the parameter provided on the KeTop T10 are listed and example
values for them are shown.
Concurrency of KVC telegrams
According to the protocol definition state requests will be transmitted cyclically
which means the executing is always one after another.
Parameter requests are carried out as necessary and have to be serialized on
the server: The server can only send another request after the acknowledge
of the previous request has been received. This ensures that each parameter
request is executed correctly.
A synchronization between status requests and inquiries parameter is not nec-
essary, since they are handled in several buffers. So state requests and
parameter requests can be handled in parallel.
KVC parameter on the KeTop T10
Parameters for changing and returning the configuration on the KeTop T10
Parameter
Example content
ScreenSaverTime
20000 [ms]
ScreenSaverState
activated
DevHWInfoData
1, 4, 0, 2549, 15308652, 86839, 15308652, 0,
23388
CpuInfoData
frequ 50000000, ram 98304
DevTypeInfo
KeTop T10, FreeRTOS
FirmwareVersion
1.4, KeTop T10 v 1.004 (Wed Nov 6 15:42:55 GMT
2013)
BootSystemVersion
1.6, KEBA Bootloader v1.06
NetConfig
192.168.137.151, 255.255.255.0, 192.168.137.1,
192.168.137.234, 0
DiagnosisDataLength
5
ClientDiagnosis
20000
DisplayTileCount
13
DisplayData
Representation of syntax <Tile#: [Set-Id/Icon-
Id]>
0:[2/12] 1:[3/1] 2:[3/1] 3:[3/1] 4:[3/1] 5:
[3/1] 6:[3/1] 7:[3/1] 8:[3/1] 9:[3/3] 10:[3/4]
11:[3/5] 12:[3/1]
MonitorCycleTime
5 (ms)
Parameter as commands for KeTop T10
Parameter
Process
Reset
Reset
Calibrate
Kalibration of the sensor
OrientationReset
Referencing = Reset of the orientation
Appendix: KVC telegrams on KeTop T10
KeTop T10
© KEBA 2014
Project engineering manual V1.02
90