EtherCAT connection between control module, supply module and axis
modules: The supply package of axis- and supply modules also contains
EtherCAT connection cables, which enable connection to the left com-
munication partner. The order designations for longer RT-Ethernetcables
are listed in the appendix.
●
Provide additional shield contact for RT-Ethernet.
5.1.1
Requirements to the connectors
The following connections are available in the system:
●
RT-Ethernet (RJ45) connectors
●
Encoder connections
●
Connections for motor
●
Connections brake resistor
●
Connections power supply
●
Voltage equalizing cable
RT-Ethernet (RJ45) connectors
If an (RT-)Ethernet cable is led outside of the cabinet, the isolation of the ca-
ble must be opened after the RJ45 plug and the cable shield must be con-
tacted on a suitable section with designated straps (lower end of the front
plate) again. The following (RT-)Ethernet connectors can be affected:
Fig. 5-9: Cable shield
1
... Cable shield with shield clamp
2
... Control module
3
... Supply module
4
... Cabinet