Preface

Tests can only be done within the application by the machine manufacturer. They must be 

repeated, even if only parts of hardware, software or the unit adjustment are modified. 

Unauthorised opening and tampering may lead to bodily injury and property damage and 

may entail the loss of warranty rights. Original spare parts and authorized accessories by the 

manufacturer serve as security. The use of other parts excludes liability for the consequences 

arising out of.

The suspension of liability is especially valid also for operation interruption loss, loss of profit, 

data loss or other damages. This is also valid, if we referred first to the possibility of such 

damages.
If single regulations should be or become void, invalid or impracticable, the effectivity of all 

other regulations or agreements is not affected.
Through multitude applications not each possible case of installation, operation or mainte-

nance can be considered. If you require further information or if special problems occur which 

are not treated detailed in the documentation, you can request the necessary information via 

the local KEB agency.

1.4 Copyright

The customer may use the instruction manual as well as further documents or parts from it for 

internal purposes. Copyrights are with KEB and remain valid in its entirety.
KEB

®

, COMBIVERT

®

, COMBICONTROL

®

 and COMBIVIS

®

 are registered trademarks of Karl 

E. Brinkmann GmbH.
Other wordmarks or/and logos are trademarks (™) or registered trademarks (®) of their re-

spective owners and are listed in the footnote on the first occurrence.

When creating our documents we pay attention with the utmost care to the rights of third par-

ties. Should we have not marked a trademark or breach a copyright, please inform us in order 

to have the possibility of remedy.

1.5 

Specified application

The used semiconductors and components of KEB are developed and dimensioned for the 

use in industrial products. If the KEB COMBIVERT F5 is used in machines, which work under 

exceptional conditions or if essential functions, life-supporting measures or an extraordinary 

safety step must be fulfilled, the necessary reliability and security must be ensured by the 

machine builder. The operation of our products outside the indicated limit values of the techni-

cal data leads to the loss of any liability claims. The safety function is limited to a service life 

of 20 years. After this time the unit must be replaced.

Содержание COMBIVERT G6

Страница 1: ...C O M B I V E R T Original Manual Mat No Rev 00G6NEF 0000 1H GB Safety Manual Safety function COMBIVERT G6 STO...

Страница 2: ......

Страница 3: ...11 3 Installation 12 4 Description of the Terminals 13 4 1 Assembly of the wires 13 4 2 Inputs 14 4 2 1 Specification of the STO inputs 14 5 Functional Description 15 5 1 Switching off 15 5 2 Switchi...

Страница 4: ...GB 4 Table of Contents...

Страница 5: ...ing or operation of the unit Aide Tip 1 2 Safety instructions Observe safety and operating instruc tions Precondition for all further steps is the knowledge and ob servance of the safety and operating...

Страница 6: ...e local KEB agency 1 4 Copyright The customer may use the instruction manual as well as further documents or parts from it for internal purposes Copyrights are with KEB and remain valid in its entiret...

Страница 7: ...Product code xx G6 x x x xxxx A B C D H I K L Validity of certificates The certification of controllers with safety tech nology since 05 2013 is only valid if the material number corresponds with the...

Страница 8: ...ternal filter without braking tran sistor without safety function STO C like 2 with STO K like C with f 0Hz 3 internal filter with braking transistor without safety function STO D like 3 with STO L li...

Страница 9: ...s of the Low Volt age Directive 2006 95 EC The harmonized standard of the se ries EN 61800 5 1 VDE 0160 is used This is a product of limited availability in accordance with IEC 61800 3 This product ma...

Страница 10: ...rgency stop can be realized only in connection with a line contactor which disconnects the mains voltage 2 1 Emergency stop according EN60204 By using suitable safety switchgear units stop category 0...

Страница 11: ...he IGBTs The error should be regarded as critical if the drive remains in STO status 2 2 Classification of STO according IEC61508 PFH 8 1 10 11 1 h PFD 7 1 10 6 on demand Proof Test Interval 20 years...

Страница 12: ...mall parts fall into the COMBIVERT during assembly and wiring This also applies to mechanical components which can lose small parts during operation Check the safety functions and error responses and...

Страница 13: ...s Assembly of connecting wires with wire end ferrules according to DIN46228 4 Cross section AWG Metal sleeve length Stripping length 0 2 0 75mm2 24 19 6mm 8 mm Assembly of connecting wires without wir...

Страница 14: ...rminals KEB generally recommends the use of wire end ferrules in industrial environ ments 4 2 Inputs 4 2 1 Specification of the STO inputs STO Inputs Status 0 Status 1 UL V IL mA UH V IH mA max 5 15 3...

Страница 15: ...mergency stop unit STO1 STO2 24V an on off on test is carried out before the modulation release to ensure that a switching off is possible Test every 24 hours In order to ensure safe operation the saf...

Страница 16: ...0 32 X2A 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Power Unit X1A Power terminal block Control Circuit X2A Control terminal block Safety component X2B STO terminal block X4A Diagnostic interface At o...

Страница 17: ...minal block X4A Diagnostic interface The displayed circuit shows wiring errors in the area of the emergency stop unit and supply line A possible short circuit on the primary side of the emergency stop...

Страница 18: ...Power Unit X1A Power terminal block Control Circuit X2A Control terminal block Safety component X2B STO terminal block Safety module X4A Diagnostic interface With operation of the emergency stop unit...

Страница 19: ...2A 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 OPEN CLOSED Acknowledgment Quittung X2B Power Unit X1A Power terminal block Control Circuit X2A Control terminal block Safety component X2B STO terminal b...

Страница 20: ...input 1 Quick stopping modulation off no auto matic restart Pn04 Source error prog input 16 I3 here in the example Function If the selected input becomes active the drive decelerates with the quick s...

Страница 21: ...stems with ad justable speed security requirements VDE0160 Part 105 09 2003 informative EN50178 1997 Installation of high voltage systems with electronic equipment VDE 0160 04 1998 EN60664 1 2007 Isol...

Страница 22: ...he T V Rheinland with the EC type examination 01 205 5183 11 The number address of the indicated constitution NB 0035 T V Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin Germany Tel 49 30 7...

Страница 23: ...ersion Rev 1F 2012 01 Inscribed certification number change DC classification to middle at chapter 2 3 extended chap ter 5 2 Rev 1G 2013 02 FS marking inserted copyright changed Rev 1H 2014 01 Extende...

Страница 24: ...nfo keb fr KEB UK Ltd Morris Close Park Farm Industrial Estate GB Wellingborough NN8 6 XF fon 44 1933 402220 fax 44 1933 400724 net www keb uk co uk mail info keb uk co uk KEB Italia S r l Via Newton...

Отзывы: