background image

GB - 21

Certification

7. 

Certification

7.1 

Annex to the declaration of conformity

Annex to the declaration of conformity EC for systems with functional safety:

Product designation:

Inverter - type series

xxG6xAx-xxxx

xxG6xBx-xxxx

xxG6xCx-xxxx

xxG6xDx-xxxx

xxG6xHx-xxxx

xxG6xIx-xxxx

xxG6xKx-xxxx

xxG6xLx-xxxx

Herewith we declare that the safety module described above corresponds with all relevant 

regulations of the machinery safety directive 2006/42/EC. 

The above mentioned safety module meets the requirements of the following guidelines and 

standards:

Machinery safety directive

2006/42/EC

EMC directive

2004/108/EC

Low-Voltage Directive

2006/95/EC

EN standards

Output Text

Reference

Output

EN 61800-5-1 09/2003 Electrical power drive systems with ad-

justable speed: security requirements

VDE 0160

Part 105

09/2003

informative:
EN 50178

1997

Installation of high voltage systems with 

electronic equipment

VDE 0160

04/1998

EN 60664-1

2007

Isolation coordinats for electrical equip-

ment in low-voltage systems

VDE 0110

01/2008

EN 61800-2

10/1998 Basic determinations for AC inverter

VDE 0160  

Part 102

08/1999

especially for systems with functional safety additionally:
EN 61800-5-2

2007

Electrical power drive systems with ad-

justable speed: functional safety require-

ments

VDE 0160

Part 105-2

04/2008

EN 61508-(1…7)

Functional safety of electrical/electronic/

programmable electronic safety-related 

systems  - Part 1 up to 7

VDE 0803

02/2011

EN 60204-1

+A1

2006

2009

Electrical equipment of machines;  

Part1: General requirements  

VDE 0113-1

+A1

2007

10/2009

EN 62061

09/2013 Safety of machinery

functional security requirements

VDE 0113  

Part 50

09/2013

EN 13849-(1,  2)

Safety of machinery

08/2008

Содержание COMBIVERT G6

Страница 1: ...C O M B I V E R T Original Manual Mat No Rev 00G6NEF 0000 1H GB Safety Manual Safety function COMBIVERT G6 STO...

Страница 2: ......

Страница 3: ...11 3 Installation 12 4 Description of the Terminals 13 4 1 Assembly of the wires 13 4 2 Inputs 14 4 2 1 Specification of the STO inputs 14 5 Functional Description 15 5 1 Switching off 15 5 2 Switchi...

Страница 4: ...GB 4 Table of Contents...

Страница 5: ...ing or operation of the unit Aide Tip 1 2 Safety instructions Observe safety and operating instruc tions Precondition for all further steps is the knowledge and ob servance of the safety and operating...

Страница 6: ...e local KEB agency 1 4 Copyright The customer may use the instruction manual as well as further documents or parts from it for internal purposes Copyrights are with KEB and remain valid in its entiret...

Страница 7: ...Product code xx G6 x x x xxxx A B C D H I K L Validity of certificates The certification of controllers with safety tech nology since 05 2013 is only valid if the material number corresponds with the...

Страница 8: ...ternal filter without braking tran sistor without safety function STO C like 2 with STO K like C with f 0Hz 3 internal filter with braking transistor without safety function STO D like 3 with STO L li...

Страница 9: ...s of the Low Volt age Directive 2006 95 EC The harmonized standard of the se ries EN 61800 5 1 VDE 0160 is used This is a product of limited availability in accordance with IEC 61800 3 This product ma...

Страница 10: ...rgency stop can be realized only in connection with a line contactor which disconnects the mains voltage 2 1 Emergency stop according EN60204 By using suitable safety switchgear units stop category 0...

Страница 11: ...he IGBTs The error should be regarded as critical if the drive remains in STO status 2 2 Classification of STO according IEC61508 PFH 8 1 10 11 1 h PFD 7 1 10 6 on demand Proof Test Interval 20 years...

Страница 12: ...mall parts fall into the COMBIVERT during assembly and wiring This also applies to mechanical components which can lose small parts during operation Check the safety functions and error responses and...

Страница 13: ...s Assembly of connecting wires with wire end ferrules according to DIN46228 4 Cross section AWG Metal sleeve length Stripping length 0 2 0 75mm2 24 19 6mm 8 mm Assembly of connecting wires without wir...

Страница 14: ...rminals KEB generally recommends the use of wire end ferrules in industrial environ ments 4 2 Inputs 4 2 1 Specification of the STO inputs STO Inputs Status 0 Status 1 UL V IL mA UH V IH mA max 5 15 3...

Страница 15: ...mergency stop unit STO1 STO2 24V an on off on test is carried out before the modulation release to ensure that a switching off is possible Test every 24 hours In order to ensure safe operation the saf...

Страница 16: ...0 32 X2A 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Power Unit X1A Power terminal block Control Circuit X2A Control terminal block Safety component X2B STO terminal block X4A Diagnostic interface At o...

Страница 17: ...minal block X4A Diagnostic interface The displayed circuit shows wiring errors in the area of the emergency stop unit and supply line A possible short circuit on the primary side of the emergency stop...

Страница 18: ...Power Unit X1A Power terminal block Control Circuit X2A Control terminal block Safety component X2B STO terminal block Safety module X4A Diagnostic interface With operation of the emergency stop unit...

Страница 19: ...2A 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 OPEN CLOSED Acknowledgment Quittung X2B Power Unit X1A Power terminal block Control Circuit X2A Control terminal block Safety component X2B STO terminal b...

Страница 20: ...input 1 Quick stopping modulation off no auto matic restart Pn04 Source error prog input 16 I3 here in the example Function If the selected input becomes active the drive decelerates with the quick s...

Страница 21: ...stems with ad justable speed security requirements VDE0160 Part 105 09 2003 informative EN50178 1997 Installation of high voltage systems with electronic equipment VDE 0160 04 1998 EN60664 1 2007 Isol...

Страница 22: ...he T V Rheinland with the EC type examination 01 205 5183 11 The number address of the indicated constitution NB 0035 T V Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin Germany Tel 49 30 7...

Страница 23: ...ersion Rev 1F 2012 01 Inscribed certification number change DC classification to middle at chapter 2 3 extended chap ter 5 2 Rev 1G 2013 02 FS marking inserted copyright changed Rev 1H 2014 01 Extende...

Страница 24: ...nfo keb fr KEB UK Ltd Morris Close Park Farm Industrial Estate GB Wellingborough NN8 6 XF fon 44 1933 402220 fax 44 1933 400724 net www keb uk co uk mail info keb uk co uk KEB Italia S r l Via Newton...

Отзывы: