Technical Data
©
2020 KEB America, Inc.
15
4.1.3 Electrical Operating Conditions
4.1.3.1 Device Classification
Requirement
Standard
Class Description
Overvoltage category
EN 61800-5-1 III
-
EN 60664-1
III
-
Pollution degree
EN 60664-1
II
Non-conductive pollution, occasional
concensation when PDS is out of service
Table 3: Device classification
4.1.3.2 Electromagnetic Compatibility
EMC Emitted
Interference
Standard
Class Description
Conducted emissions
EN 61800-3
C2
-
Radiated emissions
EN 61800-3
C2
-
Immunity
Standard
Level Description
Static discharges
EN 61000-4-2 8kV
4kV
AD (air discharge)
CD (contact discharge)
Burst – Port for process
measurement control
lines and signal interfaces
EN 61000-4-4 2kV
-
Burst – Power ports
EN 61000-4-5 4kV
-
Surge – Power ports
EN 61000-4-5 1kV
2kV
Phase-phase
Phase-ground
Immunity to conducted
disturbances induced by
radio-frequency fields
EN 6100-4-6
10V
0.15 to 80 MHz
Electromagnetic fields
EN 61000-4-3 10V/m
3V/m
1V/m
80 MHz to 1 GHz
1.2 to 2 GHz
2 to 2.7 GHz
Table 4: Electromagnetic compatibility