GB-24
Parameter Lists
5.
Parameter Lists
5.1
LF-Parameter
‘1
LF.06 = 1 high-resolution on
‘2
LF.04 = 1 SSM
Gr. No. Name
Address P E R Resol. Lower Limit Upper Limit Default Value
Unit
LF 00 Password
3500
E
1
0
9999
-4
---
LF 01 User-defined password
3501
E
1
0
9999
440
---
LF 02 Steering / operating mode
3502
E
1
1
4
1
---
LF 04 ASM/SSM-selection
3504
E
1
0:ASM
1:SSM
0:ASM
---
LF 05 Reversal of travel direction
3505
1
0:off
1:on
0:off
---
LF 06 High-resolution
3506
E
1
0:off
1:on
0:off
---
LF 19 DC voltage compensation
3513
E
1
150
501:off
400
V
LF 20 Rated system speed
3514
0,001
0,000
15,000
0
m/s
LF 21 Traction sheave diameter
3515
1
200
2000
600
mm
LF 22 Gear reduction ratio
3516
0,01
1,00
99,99
30
---
LF 23 Catenary suspension
3517
1
1
8
1
---
LF 24 Load
3518
1
0
65535
0
kg
LF 25 Torque increase of the door drive
3519
0,1
0,0
25,5
6
%
LF 26 Rated speed of the door drive
351A
1
100
6000
1440
rpm
LF 27 Rated frequency of the door drive
351B
1
20
100
50
Hz
LF 28 Rated voltage of the door drive
351C
1
1
650
400
V
LF 30 Control method
351E
E
1
0
3
0
---
LF 31 KP speed
351F
1
1
65535
3000
---
LF 32 KI speed
3520
1
0
65535
1000
---
LF 33 KI speed offset
3521
1
0
65535
1000
---
LF 34 KP current
3522
1
1
65535
1500
---
LF 35 KI current
3523
1
0
65535
500
---
LF 36 Maximum torque
3524
0,1
0
dr.10
2 * dr.9
1'1
1,5*dr.9 '2
Nm
LF 37 Torque increase
3525
0,1
0,0
25,2
10
%
LF 38 Operating frequency change
3526
1
0
1
1
---
LF 40 Set value VB, correction speed
3528
0,001
0,000
0,300
0
m/s
LF 41 Set value VE, crawl speed
3529
0,001
0,000
0,300
0
m/s
LF 42 Set value VN, rated speed
352A
0,001
0,000
LF.20
0
m/s
LF 43 Set value VI, inspection speed
352B
0,001
0,000
0,630
0
m/s
LF 44 Set value V1, intermediate speed 1
352C
0,001
0,000
LF.20
0
m/s
LF 45 Set value V2, intermediate speed 2
352D
0,001
0,000
LF.20
0
m/s
LF 46 Set speed of door drive
352E
0,5
0
16000
0
rpm
0,1 '1
2000 '1
LF 50 Starting jerk
3532
0,01
0,10
9,99
0,60
m/s^3
LF 51 Acceleration
3533
0,01
0,10
2,00
0,90
m/s^2
LF 52 Deceleration jerk
3534
0,01
0,10
9,99
1,00
m/s^3
LF 53 Deceleration
3535
0,01
0,10
2,00
0,60
m/s^2
LF 54 Stopping jerk
3536
0,01
0,01:off
9,99
0,01:off
m/s^3
LF 55 Starting jerk VE (crawl speed)
3537
0,01
0,10
9,99
0,60
m/s^3
LF 56 Acceleration VE (crawl speed)
3538
0,01
0,10
2,00
0,90
m/s^2
LF 57 Speed Deviation mode
3539
1
0
2
1
---
LF 58 Speed deviation level
353A
1
0
30
10
%
LF 59 Speed diviation - release time
353B
0,001
0,000
10,000
3,000
s
LF 60 Switching level brake disconnection
353C
0,001
0,000
0,010
0,005
m/s
LF 61 Monitoring overspeed
353D
0,001
0,000
18,000
1,1 * LF.42
m/s
LF 62 Deceleration check level
353E
0,001
0,000
15,000
0,95 * LF.42
m/s
LF 63 Running open door level
353F
0,001
0,000
0,300
0,250
m/s
Содержание COMBIVERT F4-F
Страница 29: ......