105
DrAWINGS
7.2 LED description
1
Figure 85: LED position detail
2 3 4 5
LED Reference
Color
Function
Ext. / Int.
1
Front LED
Yellow/Green
On/Off
Standby/µUPS
External
2
DL4
Red
Thermal Alarm
External
3
DL2
Red
Watchdog
External
4
DL3
Yellow
Mass Storage
Device
External
5
DL1
Green
Power On / standby
External
/
DL5
Green
Touchscreen
Internal
Figure 86: LED position detail
7.2.1 DL4 - Thermal Alarm LED
This LED is used to notify a thermal alarm coming from inside C6 E22 BOX/PANEL. Two
temperature are measured by mean of Super I/O Nuvoto NCT6106D hardware monitor
integrated circuit:
• Motherboard close to CPU temperature.
• Motherboard temperature at the input aeration.
Measuring point
Thermal limit
CPU
100°C
Mother board
80°C
In case this LED is on, please shut off the system and check its cooling and power con-
sumption.