Encoder Interface UVW / TTL Input
GB-6
2.3
Mechanical installation
All kind of works on the inverter may be carried out by authorized personnel in accordance
with the EMC and safety rules only.
• Switch inverter de-energized and await capacitor discharge time
• Pull off operator
• Remove plastic cover
• Remove fixing bolt
• Fix interface board beginning from the socket connector straightly
• Screw in fixing bolt
• Attach plastic cover
3.
Description of the Interface
3.1
Voltage supply
Figure 3.1 Voltage supply of control and encoder interfaces
U
int
24 VDC
Internal voltage supply of COMBIVERT.
X2A
X3A
X3B
5,2V
24V
5V
24V
5V
U
int
����
I
int
140 mA
U
ext
Control terminal strip (X2A) of the COMBIVERT with
external voltage supply 24…30 DCV.
24 V Voltage output of encoder interfaces X3A and X3B for
encoder supply.
I
24V
Current I
int
reduces itself by draw current to the 5 V output
in accordance with the following formula:
5,2 V x I
5V
I
24V
= I
int
- –––––––––
U
int
5 V Voltage output for encoder supply. 5,2 V are obtained
from the 24 V voltage.
I
5V
400 mA Total for both encoder interfaces