background image

Record the Serial number and Model number of this Incredible Frying Machine™ in 
the spaces provided. 

Keep these numbers for future reference.

INCREDIBLE FRYING MACHINE™ 

GAS FRYER

SERIES 2006

KEEP A COPY OF YOUR BILL OF SALE. 

The date on the bill establishes the warranty period should service be required. 
If service is performed, it is in your interest to obtain and keep all receipts.

Keating commercial fryers are not intended for household use.

As continuous product improvement occurs, specifi cations may be 
changed without notice.

IMPORTANT:

THE USER'S MANUAL PROVIDES SPECIFIC OPERATING INSTRUCTIONS 
FOR YOUR MODEL. USE THE INCREDIBLE FRYING MACHINE™ ONLY AS 
INSTRUCTED IN THIS MANUAL.

Part # 017411

 IfmGas2006_2013

11/13

1-800-KEATING  |  keatingofchicago.com

MANUAL

KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL.

SERIAL NUMBER

MODEL NUMBER

Содержание SERIES 2006

Страница 1: ...is performed it is in your interest to obtain and keep all receipts Keating commercial fryers are not intended for household use As continuous product improvement occurs specifications may be changed without notice IMPORTANT THE USER S MANUAL PROVIDES SPECIFIC OPERATING INSTRUCTIONS FOR YOUR MODEL USE THE INCREDIBLE FRYING MACHINE ONLY AS INSTRUCTED IN THIS MANUAL Part 017411 IfmGas2006_2013 11 13...

Страница 2: ...FACTURER S INSTRUCTIONS THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM THE EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE BASIC PLUMBING CODE OF THE BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL INC BOCA AND THE FOOD...

Страница 3: ...Alterations of any kind to your equipment will void the warranty Before uncrating check equipment carefully for damage IF EQUIPMENT ARRIVES DAMAGED Keating does not assume responsibility for loss or damage incurred in transit IMPORTANT This merchandise has been thoroughly inspected and carefully packed before leaving our plant Responsibility for its safe delivery was assumed by the carrier at the ...

Страница 4: ... High temperature stainless steel flue lining 100 factory testing STANDARD ACCESSORIES Keating Klenzer Sample Drain clean out rod OPTIONS Natural Gas or Propane Automatic Basket Lift Cooking Computer RATINGS 14 fryer vessel 38 lb oil capacity 18 fryer vessel 68 lb oil capacity 20 fryer vessel 100 lb oil capacity 7 W C Natural Gas or 11 W C Propane Line Gas Pressure 3 WC Natural Gas or 10 WC Propan...

Страница 5: ... hot oil NEVER introduce objects or liquids into fryer while operational which are not designed or made for cooking THIS FRYER MAY NOT BE ALTERED MODIFIED OR CHANGED IN ANY WAY The State of California enacted the California Safe drinking water and Toxic Enforcement Act of 1986 Prop 65 which prohibits any person in the course of doing business from knowingly and intentionally ex posing any individu...

Страница 6: ...allow the restrain ing bolt to be anchored to the cabinet back between the cabinet bottom and inner liner If disconnection of the restraint is necessary it must be reconnected when the Keating IFM is returned to its originally installed position NOTICE WHEN THIS APPLIANCE IS INSTALLED WITH CASTERS IT MUST BE INSTALLED WITH CASTERS SUPPLIED A CONNECTOR COMPLYING WITH EITHER ANSI Z21 69 OR CAN CGA 6...

Страница 7: ...S FOR USING THE GAS PRESSURE TAP INCLUDED ON FRYER BATTERY WITH COMMON MANIFOLD MANUFACTURED AFTER 8 19 10 Part 060265 The gas pressure tap is available on batteried fry ers with common manifold piping manufactured after 8 19 10 Keating batteries are often equipped with a common manifold that supplies gas to each product in the battery requiring only a single service sup ply hook up A pressure tap...

Страница 8: ...NE GAS SUPPLIER FOR ASSISTANCE OPERATING FILLING NOTE Before filling the fryer make certain the fryer vessel is sanitized dry and the drain valve is completely closed Refer to item 13 on page 17 or 11 on page 19 for location of drain valve NOTE We recommend that solid shortening not be used in an Incredible Frying Machine IFM as they are not equipped with a melt cycle If solid shortening is used i...

Страница 9: ... SPLASHING HOT OIL FROM FRYER VESSEL NEVER LIFT BASKETS DIRECTLY OUT OF THE FRYER VESSEL WITHOUT DRAINING AS SEVERE INJURY MAY RESULT 1 Set thermostat to the desired frying temperature between 325 F 335 F 2 When the oil reaches the desired temperature burner indicating light will go off 3 Set timer s to desired cooking time and fill basket s to proper level if applicable 4 Lower filled basket s sl...

Страница 10: ...URE To pause a cycle in progress press any button The relay output contacts will open the display will flash and the countdown will pause To resume the count down press any button The display will resume the normal countdown and the relay output contacts will close CANCELING A CYCLE To cancel a cycle in progress press and hold any but ton for approximately two seconds The relay output contacts wil...

Страница 11: ...pump water through the filter machine 11 Spread Keating Klenzer liberally on tubes and sides of fryer vessel 12 A non abrasive scouring pad may be used to remove the now softened carbonized grease 13 Thoroughly rinse fryer vessel with potable water to remove all Klenzer 14 Prior to refilling with oil wipe the inside of the fryer vessel making sure all water and Klenzer has been removed WATER IN AN...

Страница 12: ...bulb is placed properly against the heat transfer tube To quickly and accurately test for proper bulb placement a single thickness of writing paper should be pulled through between the tube and the bulb with medium resistance 1 For 14 IFM Fryers The end of thermostat bulb should touch the burner tube 1 For 18 20 IFM Fryers If the bulb is too loose the paper will slip through with little or no resi...

Страница 13: ...continuity 3 If the switch does not show continuity during all ten trials replace the thermostat Disassembling the thermostat will void the ther mostat warranty 1 Set compression ring onto capillary end of bulb finger tight 1 2 from end of capillary 2 Insert new thermostat bulb through control panel back 3 Apply oil resistant flexible sealant on to compres sion fitting thread before installing fit...

Страница 14: ...n as far as possible locking it into place and activating the safety switch b Reset the high limit press the red button located in the bottom of the control panel c Reset the breaker located on the bottom of the control panel check the outlet or check the breaker at the wall Timers or lights ON but fryer does not try to light a Thermostat off a Set the thermostat to desired temperature Blower ligh...

Страница 15: ...ight c Reset Hi Limit after oil has cooled down below 425 F Correct problem which caused Hi Limit to activate See page 20 d Secure drain handle in place behind the bracket Burner light does not come on Check for flame at each burner If no flame is present at either burner a Spark module is faulty Check for flame at each burner If flame is present at both burners b Burner light is faulty a Replace ...

Страница 16: ...d b Thermostat out of calibration a Adjust bulb position See page 10 Thermostat Bulb Positioning b Calibrate thermostat See page 10 Calibration Oil in fryer vessel smokes a Oil has begun to break down b High carbon content in oil c Dirty fryer vessel d Inferior grade of oil e Fryer is overheating a Replace oil b Filter oil completely replace if necessary c Boil out fryer See page 8 Cleaning and Bo...

Страница 17: ... too many flame losses 1 Turn off unit 2 Check incoming gas 3 Spark at electrode 4 Electrode g Control hardware fault detected ORDERING PARTS Parts may be ordered by calling 1 800 KEATING or your local Keating service company You may also order on line at Keating s part store www keatingofchicago com Refer to the Keating Gas Fryer Limited Warranty for complete service and ordering information The ...

Страница 18: ... 2 8 FLEXIBLE PILOT TUBING 054208 2 9 MAGNETIC REED SWITCH 053777 1 10 NIPPLE QUICK CONNECT 052572 1 RUBBER GROMMET 053445 1 11 KNOB DRAIN HANDLE 031532 2 12 GAS VALVE NAT 024030 1 LP 024988 1 13 14 DRAIN VALVE 1 REAR 016341 1 18 20 DRAIN VALVE 1 1 4 REAR 016342 1 14 ALL DRAIN VALVE PULL ROD ASSEMBLY 14 DRAIN VALVE HANDLE ROD 053650 18 20 DRAIN VALVE HANDLE ROD 059742 DRAIN VALVE ADJUSTMENT SLEEVE...

Страница 19: ...S FRYER REAR DRAIN MODEL 2000 Corresponds with Parts List on Page 16 1 3 2 15 16 17 18 13 14 7 8 10 9 4 5 6 11 12 19 20 Burner Electrode Assembly See Detail on Page 27 Oil Return Piping Assembly Enlarged View FRONT VIEW SIDE VIEW Not shown See pages 21 22 for Control Panel Parts List ...

Страница 20: ...1 4 S S 15 LONG 054208 1 9 ALL FLEX TUBING 3 8 S S 6 LONG 054512 2 ALL COMPRESSION 3 8 x 1 8 90 ELBOW 054426 2 ALL TAPE 1 2 x 520 TEFLON 015331 A R 10 ALL GAS VALVE NATURAL GAS 024030 1 ALL GAS VALVE LP 024988 1 11 14 DRAIN VALVE 1 FRONT 004553 1 18 20 DRAIN VALVE 1 1 4 FRONT 004554 1 12 ALL CASTER SWIVEL LOCKING 037537 2 13 ALL CASTER RIGID 037539 2 14 14 CENTER TUBE DIVIDER BAFFLE ASSEMBLY 14 MO...

Страница 21: ...FRYING MACHINE SERIES 2006 19 INCREDIBLE FRYING MACHINE GAS FRYER FRONT DRAIN MODEL 2006 Corresponds with Parts List on Page 18 1 11 12 13 2 3 7 8 10 9 4 14 5 6 FRONT VIEW SIDE VIEW See pages 23 26 for Control Panel Parts List ...

Страница 22: ...MIT BURNER MOUNTING BRACKET CENTER TUBE COVER PLATE CENTER TUBE DIVIDER THERMOSTAT BURNER ASSEMBLY Page 25 INSULATION FLUE BOX FLUE FRY POT with Front Drain INCREDIBLE FRYING MACHINE GAS FRYER ASSEMBLY FRONT DRAIN For reference only ...

Страница 23: ...MODEL 035574 1 THERMOSTAT 18 20 MODELS 035575 1 THERMOSTAT DIAL PLATE 058037 1 THERMOSTAT KNOB BLACK 060612 1 10 CIRCUIT BREAKER 053338 1 11 RECEPTACLE SNAP IN 125 VAC 011505 1 12 6 CIRCUIT QUICK CONNECT FEMALE 028301 1 FEMALE PINS 028308 6 13 2 CIRCUIT QUICK CONNECT FEMALE 032207 1 FEMALE PINS 028308 6 14 TRANSFORMER 120V 24V 024032 1 15 4 CIRCUIT QUICK CONNECT FEMALE 032211 1 FEMALE PINS 028308 ...

Страница 24: ...0612 1 10 CIRCUIT BREAKER 053338 1 11 RECEPTACLE SNAP IN 125 VAC 011505 1 12 6 CIRCUIT QUICK CONNECT FEMALE 028301 1 FEMALE PINS 028308 6 13 2 CIRCUIT QUICK CONNECT FEMALE 032207 1 FEMALE PINS 028308 6 14 TRANSFORMER 120V 24V 024032 1 15 4 CIRCUIT QUICK CONNECT FEMALE 032211 1 FEMALE PINS 028308 6 16 SNAP IN BUSHING 1 005664 3 17 TERMINAL BOARD WITH INSULATION 004153 1 18 12 CIRCUIT QUICK CONNECT ...

Страница 25: ...NITION MODULE 037550 2 7 RELAY DPDT 24VAC 030844 5 8 CIRCUIT BREAKER 053338 1 9 RECEPTACLE SNAP IN 125 VAC 011505 1 10 TRANSFORMER 120V 24V 024032 1 11 SNAP IN BUSHING 1 005664 3 12 TERMINAL BOARD WITH INSULATION 004153 1 13 HIGH LIMIT Resettable 034357 1 14 STRAIN RELIEF BUSHING 000430 1 15 POWER CORD 120V 9FT 006311 1 16 RELAY 35 SECOND DELAY 24VAC 035080 1 16 SPARK IGNITION CABLES 037551 2 17 R...

Страница 26: ... 1 BACK MOUNT 004341 BOTTOM MOUNT 034357 11 RELAY DPDT 24VAC 030844 2 12 TERMINAL BOARD WITH INSULATION 004153 1 13 THERMOSTAT 14 MODEL 035574 1 THERMOSTAT 18 20 MODELS 035575 1 14 THERMOSTAT DIAL PLATE 375 058037 1 15 THERMOSTAT KNOB BLACK 060612 1 16 RECEPTACLE 125V 15A SNAP IN 011505 1 17 BUSHING BLACK PLASTIC SNAP IN 7 8 000514 1 18 BUSHING BLACK PLASTIC SNAP IN 1 005664 2 19 BUSHING STRAIN RE...

Страница 27: ...ACK 060612 1 THERMOSTAT DIAL PLATE 058037 1 THERMOSTAT 14 MODEL 035574 1 THERMOSTAT 18 20 MODELS 035575 1 9 SPARK IGNITION ELECTRODE LEAD 24 059303 2 10 HIGH LIMIT MANUAL RESET 1 800 KEATING 1 BACK MOUNT BOTTOM MOUNT 11 TRANSFORMER STEPDOWN 24VAC 80VA 024032 1 12 TERMINAL BOARD WITH INSULATION 004153 1 13 SPARK IGNITION MODULE IFM 24VAC 060826 1 14 RELAY DPDT 24VAC 030844 1 15 CIRCUIT BREAKER 3 AM...

Страница 28: ...RMOSTAT 035575 2 THERMOSTAT DIAL PLATE 250 375 F 058037 1 THERMOSTAT KNOB BLACK 060612 1 8 SPARK IGNITION MODULE IFM 24VAC 037550 2 9 TRANSFORMER STEPDOWN 24VAC 80VA 024032 1 10 CIRCUIT BREAKER 3 AMP 1 POLE 250V 053338 1 11 HIGH LIMIT MANUAL RESET 034357 1 12 RELAY DPDT 24VAC 030844 3 13 RELAY 35 SECONDS 058684 1 14 TERMINAL BOARD WITH INSULATION 004153 1 15 BUSHING BLACK PLASTIC SNAP IN 1 005664 ...

Страница 29: ...AL GAS 052562 1 LP 052908 1 3 ALL OBSERVATION WINDOW ASSEMBLY LENS 016101 1 COVER 015905 1 4 ALL BURNER OUTER PLATE ELBOW ASSEMBLY LEFT OR RIGHT SIDE 022158 1 5 ALL BURNER TO PLATE SEALING GASKET 016505 1 6 ALL BURNER TO TUBE SEALING GASKET 016504 2 2 1 5 6 3 90 ORIFICE HOLDER BURNER ORIFICE 4 IFM BURNER ASSEMBLY Right side shown 0 125 1 000 0 015 Critical Dimensions for Proper Spark Ignitor Gap 1...

Страница 30: ...L S S 054522 1 14 CONNECTOR 2 CIRCUIT PLUG 032208 1 CONNECTOR CONTACT PIN MALE 028309 2 15 PIN BASKET LIFT NON ROTATIONAL 054760 1 This circuit breaker can be found under the control panel on newer units BASKET LIFT POWER SUPPLY BOX BASKET LIFT ASSEMBLY not shown to scale Bottom View Top View 8 7 1 4 6 5 Top View Side View 2 3 Basket Lift Power Supply Box Basket Lift Assembly Housing 10 9 15 14 12...

Страница 31: ...roperly secured Tug test all crimp on connectors in the same fashion 3 8 SINGLE BASKET LIFT POWER SUPPLY BOX SEE TRANSFORMER CONNECTION CHART RECTIFIER AR NOTE A separate wiring diagram has been included with this manual and should be saved for troubleshooting and maintaining the fryer The wiring diagrams in this section cover standard fryers which may or may not match the diagram sent with the fr...

Страница 32: ... keatingofchicago com 30 14 IFM 120V CONNECTION DIAGRAM NO TIMERS FRONT DRAIN MODEL 2000 Control Panel Insert Control Panel Back ...

Страница 33: ...1 800 KEATING INCREDIBLE FRYING MACHINE SERIES 2006 31 IFM 120V CONNECTION DIAGRAM TIMERS FRONT DRAIN WITH LIGHTED ROCKER SWITCH MODEL 2000 Control Panel Insert Control Panel Back ...

Страница 34: ... keatingofchicago com 32 14 IFM MODEL 2006 FRONT DRAIN WITHOUT LIGHTED ROCKER SWITCH ...

Страница 35: ...1 800 KEATING INCREDIBLE FRYING MACHINE SERIES 2006 33 14 IFM MODEL 2006 WITH SAFE AND EASY FILTER ...

Страница 36: ... keatingofchicago com 34 14 IFM MODEL 2006 CPU BASKET LIFT FRONT DRAIN ...

Страница 37: ...1 800 KEATING INCREDIBLE FRYING MACHINE SERIES 2006 35 18 20 IFM MODEL 2006 FRONT DRAIN WITH LIGHTED ROCKER SWITCH ...

Страница 38: ... keatingofchicago com 36 18 20 IFM MODEL 2007 FRONT DRAIN WITHOUT LIGHTED ROCKER SWITCH ...

Страница 39: ...1 800 KEATING INCREDIBLE FRYING MACHINE SERIES 2006 37 18 20 IFM MODEL 2007 WITH SAFE AND EASY FILTER WITHOUT LIGHTED ROCKER SWITCH ...

Страница 40: ... keatingofchicago com 38 BOB EVANS IFM 120V CONNECTION DIAGRAM NO TIMERS REAR DRAIN MODEL 2006 WITH TOGGLE SWITCHES Effective 5 2006 ...

Страница 41: ...1 800 KEATING INCREDIBLE FRYING MACHINE SERIES 2006 39 IFM 120V CONNECTION DIAGRAM TIMERS FRONT DRAIN MODEL 2006 WITH TOGGLE SWITCHES Effective 5 2006 ...

Страница 42: ......

Страница 43: ...RRANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE Have your serial and model number available when ordering parts As continuous product improvement occurs specifications may be changed without notice KEATING LIMITED WARRANTY CARD FRYER GRIDDLE CUST...

Отзывы: