background image

SERIES 2000 FRYER MANUAL

INSTANT RECOVERY

®

GAS FRYER

READ AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Record the Model No. and Serial of this Instant Recovery® Gas Fryer in the space provided below.

Serial No. __________________________

Model No. __________________________

Keep these numbers for future reference

IMPORTANT

: Keep a copy of your bill of sale. The date on the bill establishes the warranty period should ser-

vice be required. If service is performed, it is in your interest to obtain and keep all receipts. Keating com-
mercial fryers are intended for other than household use.

CONTENTS:

Gas Fryer 2000

08/11

Important Safety Instructions  . . . . . . . . . . . . . . .i

INTRODUCTION

 . . . . . . . . . . . . . . . . . . . . . . . .1

INSTALLATION

Damage During Shipment . . . . . . . . . . . . . . . . .1

FIRST STEPS

Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Ventilation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
National Code Requirement  . . . . . . . . . . . . . . .1
Gas Connectors & Pipe Size  . . . . . . . . . . . . . .2
Flexible Gas Connection & Quick Disconnect
Devices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Restraining Devices  . . . . . . . . . . . . . . . . . . . . .2
Electrical Connection  . . . . . . . . . . . . . . . . . . . .2
Leveling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

PLACING YOUR KEATING FRYER IN OPERA-
TION

Filling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Lighting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
Cooking  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
Shutdown  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Oil Breakdown . . . . . . . . . . . . . . . . . . . . . . . . . .6
Draining  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Cleaning and Boil-Out  . . . . . . . . . . . . . . . . . .6-8

OPERATOR SELF HELP CHECK LIST

8

PREVENTATIVE MAINTENANCE

Preventive Maintenance Chart  . . . . . . . . . . . . .9
Hi-Limit Check Bi-Monthly . . . . . . . . . . . . . . . . .9
Thermostat Calibration  . . . . . . . . . . . . . . . . . . .9
Thermostat Bulb Positioning  . . . . . . . . . . . . . . .9
Timer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

WARRANTY REPAIRS

Ordering Parts  . . . . . . . . . . . . . . . . . . . . . . . . .11
Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . .11-15
Wiring Diagrams  . . . . . . . . . . . . . . . . . . . .15-18

1-800-KEATING

w w w. k e a t i n g o f c h i c a g o . c o m

This Owner’s Guide provides specific operating instructions for your model. Use the Instant Recovery®
Fryer only as instructed in this Service Guide.

Versión en español

Si desea obtener usa copia en español de estes Manual del Usario, sirvase escribir la dirección que
se incluye a continuadión.

Содержание Miraclean 2000

Страница 1: ...ioning 1 Ventilation 1 National Code Requirement 1 Gas Connectors Pipe Size 2 Flexible Gas Connection Quick Disconnect Devices 2 Restraining Devices 2 Electrical Connection 2 Leveling 3 PLACING YOUR K...

Страница 2: ...l gas supplier THE EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE BASIC PLUMBING CODE OF THE BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL INC BOCA AND THE FOOD SER VICE SANITATION MANUAL...

Страница 3: ...will be supplied by the car rier DO NOT RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE FIRST STEPS POSITIONING Keep appliance area free and clear of any com bustibles Position the Kea...

Страница 4: ...age to the gas valve The required gas pressure for proper operation of each fryer is 4 water col umn for natural gas and 10 water col umn for propane gas at the burner manifold If more than one gas un...

Страница 5: ...ers on ALWAYS disconnect fuel source and power supply before servicing NEVER move a fryer when full of oil NEVER introduce objects or liquids into fryer while operational which are not designed or mad...

Страница 6: ...will come on HIGH LIMIT TEST PROCEDURE All Models DO BI MONTHLY STEP 1 Place a suitable thermometer in the oil on the front left corner of the fryer 2 from the top to check temperature STEP 2 Set the...

Страница 7: ...ER switch to ON posi tion Its green light and the timers will come on STEP 3 Light constant pilot located on left side of pilot runner tube STEP 4 Hold the PUSH TO LIGHT switch for 30 seconds The pilo...

Страница 8: ...realize substantial savings in oil costs as well as maintenance charges We have listed some of the conditions which are catalysts in the breakdown of oil 1 Contact with Oxygen 2 Carbonization of Crum...

Страница 9: ...ly rinse fryer vessel with potable water to remove all Klenzer Prior to refilling with oil wipe the inside of the fryer vessel making sure all water and Klenzer have been removed NOTE Do not pump wate...

Страница 10: ...ssel making sure all water and Klenzer have been removed DO NOT DAMAGE OR REPOSITION THERMOSTAT PROBE AS THIS MAY AFFECT THE ACCURACY OF THE FRYER C CA AU UT TI IO ON N DO NOT MIX WATER AND HOT OIL 12...

Страница 11: ...THERMOSTATS These operational problems can easily be correct ed by thermostat bulb positioning Keating s patented thermostat application is accu rate within 2 F of the dial setting between 250 F 350 F...

Страница 12: ...r fryer 10x11 18 up The end of thermostat bulb should touch the burner tube for 14 fryers 6 Replace burners 7 Replace control panel back 8 Slide back fabric shield over capillary and care fully coil c...

Страница 13: ...lon will flash at a one second rate When the countdown has reached 00 00 the relay output contacts will open the display will flash and the audible alarm will sound To can cel the audible alarm press...

Страница 14: ...6 G 1 SWITCH ROCKER WHITE MOMENTARY PUSH TO LIGHT 032297 H 1 INDICATING LIGHT AMBER 021254 J 1 SWITCH ROCKER WHITE LIGHT REPLACEMENT KIT 058328 K 1 SWITCH ROCKER WHITE MOMENTARY HIGH LIMIT TEST 032297...

Страница 15: ...Drain Shown QTY DESCRIPTION P N A 3 3 FIN RADIANT 000041 B 1 POT 14 GAS WELDMENT Call 800 KEATING C 3 BURNER 028048 D 1 DRAIN VALVE 004553 1 REAR DRAIN VALVE NOT SHOWN 016341 E 1 RUNNER PILOT ASSEMBLY...

Страница 16: ...LP 023624 POT ASSEMBLY 20BB 20TS GAS Front Drain Shown QTY DESCRIPTION P N A 4 3 FIN RADIANT 000041 B 1 POT 20 GAS WELDMENT Call 800 KEATING C 4 BURNER 028048 D 1 DRAIN VALVE 004554 1 DRAIN VALVE 2 FR...

Страница 17: ...15 AA2000 ELECTRICAL ASSEMBLY BB2000 ELECTRICAL ASSEMBLY...

Страница 18: ...16 Electrical Assembly not shown to scale TS2000 ELECTRICAL ASSEMBLY Electrical Assembly not shown to scale BB ELECTRICAL ASSEMBLY WITH SE FILTER...

Страница 19: ...17 TS ELECTRICAL ASSEMBLY WITH SE FILTER BASKET LIFT ELECTRICAL ASSEMBLY ALL FRYERS...

Страница 20: ...Stir oil repeatedly with a paddle until water boils off Filter oil If necessary allow oil to cool Drain about one quart of it to remove remaining water Basket lift mechanism a Connections are loose or...

Страница 21: ......

Страница 22: ..._______________________________________________________________ INVOICE NUMBER ____________________ SERIAL NUMBER ________________________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS _________...

Отзывы: