GAS CONNECTIONS AND PIPE SIZE

The Miraclean

®

Griddle requires a standard gas pipe

size of 3/4 inch (19mm) I.D. connection. The size of the
gas supply pipe is very important if the pipe is too small
you will have low gas pressure at the Miraclean

®

Griddle manifold. Low gas pressure will cause slow
recovery and/or delayed ignition. If you have a question
about gas pipe size call your local gas company.

Before connecting new pipe to the Miraclean

®

Griddle

the pipe must be blown out to remove all foreign
particles. These particles in the controls or burners may
cause improper or dangerous operating conditions.

Pipe joint compounds that are used on threaded joints
of appliance piping shall be resistant to the action of
liquified petroleum gases. When using pipe joint
compound do not apply to the first two threads. Use
only very small amount and only on male threads. This
will prevent clogging of burner orifices and the gas
valve. Never use compound on female threads as it
might be pushed into the gas valve.
Have your installer check for gas leaks using a soap
and water solution before operating. DO NOT USE AN
OPEN FLAME TO CHECK FOR GAS LEAKS.
1) The Miraclean

®

Griddle and its individual shut off

valves must be disconnected from the gas supply
piping system during any pressure  testing of that
system at test pressures in excess of 1/2 psi (3.45kPa)
(13.84 in WC) High pressure can damage the gas

valve causing a hazardous condition.
2.) The appliance must be isolated
from the gas supply piping system by
closing its individual manual shutoff
valve during any pressure testing of
the gas supply piping system at test
pressures equal to or less than 1/2 psi
(3.45 kPa). 
The required gas pressure for proper
operation of each Miraclean

®

Griddle

is 4" water column for natural gas and 10" water
column for propane gas at the manifold.
If more than one gas unit is on the same supply line,
you may require a larger line. Consult your local gas
company to assure adequate volume and pressure.
Refer to serial plate for proper gas requirement for your
particular model.

FLEXIBLE GAS CONNECTORS AND QUICK

DISCONNECT DEVICES

For an appliance equipped with casters:
The installation shall be made with a connector that
complies with the Standard for Connectors for Movable
Gas Appliances, ANSI Z21.69 or the Standard for
Connectors for Moveable Gas Appliances, CAN/CGA-
1.16, and a quick disconnect device that complies with
the Standard for Quick-Disconnect Devices for Use
With Gas Fuel, ANSI Z21.41 or the Standard for Quick
Disconnect devices for Use with Gas Fuel, CAN1-6.9. 

RESTRAINING DEVICES

Adequate means must be provided to
limit the movement of the appliance
without depending on the connector
and the quick-disconnect device or its
associated piping to limit the
appliance movement.
Griddle installation on stands with
caster, casters and jam nuts must be
completely tightened.
The restraint means must be attached

to the rear of the Miraclean

®

Griddle within 2" of the

center line and approximately 1-5/8" from the bottom of
the cabinet back to allow the restraining bolt to be
anchored to the cabinet back between the cabinet
bottom and inner liner to ensure positive support to
restrain Miraclean

®

Griddle movement and not depend

on the flexible gas connector, quick-disconnect or
piping to limit the Miraclean

®

Griddle movement.

If disconnection of the restraint is necessary, it must be
reconnected when the Miraclean

®

Griddle is returned to

its originally installed position.

LEVELING

The Miraclean

®

Griddle will operate at its highest

efficiency when properly leveled. Place a level on the
Miraclean

®

Griddle plate from side to side. For griddles

on legs, the bottom foot of the leg is adjustable. Turn
counterclockwise to decrease height, or clockwise to
increase height until level. For griddles on stands with
casters, the casters are adjustable by loosening the
jam nut. When the desired level is reached, tighten the
jam nut. Adjustments of more than 3/4" are not
recommended on any caster. The same procedure
should be followed to level the Miraclean

®

Griddle from

front to back.

2

WARNING

Do not use

open flame

to check for leaks.

WARNING

Restraining devices

required.

Содержание 37399

Страница 1: ...OUBLE SHOOT CHART 9 THERMOSTAT REMOVAL REPLACEMENT 10 11 SERVICE 10 12 WIRING DIAGRAM 13 CONTENTS IMPORTANT Keep a copy of your bill of sale The date on the bill establishes the warranty period should...

Страница 2: ...ALLY LOSE ITS ODOR AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE THAT PROPANE GAS IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR IF THERE IS ANY DOUBT YOU SHOULD CALL YOUR LOCAL PROPANE GAS SUPPLIER...

Страница 3: ...RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE FIRST STEPS POSITIONING Keep appliance area free and clear of any combustibles Position the Miraclean Griddle 6 inches 152mm from any co...

Страница 4: ...ure Refer to serial plate for proper gas requirement for your particular model FLEXIBLE GAS CONNECTORS AND QUICK DISCONNECT DEVICES For an appliance equipped with casters The installation shall be mad...

Страница 5: ...te to determine if the burner is set up for the proper type gas before connecting the quick disconnect or piping from the building gas supply pipe a Gas pressure at manifold NATURAL GAS 4 0 in W C b G...

Страница 6: ...food being cooked more rapidly than other griddle plates because the food is placed directly on the metal surface It is the understanding of this rapid heat transfer that permits the practical and be...

Страница 7: ...ventional griddles at least start at lower temperatures You may be able to work the temperature up as you become accustomed to the more rapid cooking of the Miraclean Griddle 2 Cook as usual but after...

Страница 8: ...clean surface is irreplacable NEVER USE A GRIDDLE STONE BRICK OR SCREEN TO CLEAN THE MIRACLEAN SURFACE DAMAGE DONE TO THE MIRACLEAN SURFACE BY GRIDDLE STONE BRICK OR SCREEN WILL VOID THE WARRANTY DO N...

Страница 9: ...ition your griddle surface 1 Follow cleaning instructions on page 5 2 Heat the MIRACLEAN to 400 F for one hour 3 Lower thermostat to 350 F allowing the MIRACLEAN to cool to about 350 F as is evident w...

Страница 10: ...T ELBOW 1 2 004194 14 ORIFICE HOLDER ASSEMBLY REFERENCE ONLY 15 FITTING 1 2 NPT MALE 000615 16 BURNER TUBE 1 2 X 9 1 800 KEATING 17 ELBOW 1 2 x 3 8 006477 18 GAS VALVE MILLIVOLT NATURAL GAS 023625 PRO...

Страница 11: ...is in pilot position c Thermostat is not turned on d Low gas presssure e Gas valve failure a Put ON OFF switch to ON position b Turn knob to ON position c Turn thermostat to desired temperature d Set...

Страница 12: ...NT 1 Lower the control panel by removing the screws 2 Disconnect the wires on the switch and remove switch 3 Snap the new switch into place and reconnect all wires 4 Return the control panel to its no...

Страница 13: ...having a 1 1000MV range Conduct each check below by connecting meter test leads to terminals as indicated All readings are closed circuit A BURNER COIL CHECK A Reading Thermostat contacts CLOSED Gas...

Страница 14: ...maximum output is observed Then extinguish pilot and observe meter 2 Dropout of automatic pilot magnet sound should be audible should occur between 75 millivolts and 25 millivolts If dropout occurs ou...

Страница 15: ...13 GAS GRIDDLE WIRING DIAGRAM CONTROL PANEL THERMOSTAT ON OFF SWITCH...

Страница 16: ...SE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installa...

Страница 17: ..._________________________________________________________ ADDRESS __________________________________________________________________________________________________________________ CITY ______________...

Отзывы: