1-800-KEATING
|
GAS FRYER - SERIES 2009
9
SERIES 2000-2010 CPU MODELS
OPERATING INSTRUCTIONS
DO NOT START FRYER WITHOUT FIRST FILLING FRY
POT.
START-UP PROCEDURE
1. Light mini pilot located next to the left burner
when facing fryer.
2. Turn gas supply to the “ON” position.
3. Depress the “MAIN POWER” switch to the “ON”
position.
4. Make sure CPU is turned off.
5. Engage the (Push to Light) switch and hold
until indicator light remains on or the pilot
runner tube remains lit.
6. Turn the CPU on by pressing on/off button.
7. Select melt cycle or heat cycle.
8. Select the desired temperature. See the
computer manual for more information.
SHUTDOWN PROCEDURE
1. Turn CPU off by pressing the on/off button.
2. Depress the main power switch to the “OFF”
position.
3. Turn gas supply to the “OFF” position.
4. Wait fi ve minutes before restarting or
relighting fryer
SERIES 2000 CPU SPARK IGNITION MODELS
OPERATING INSTRUCTIONS
DO NOT START FRYER WITHOUT FIRST FILLING FRY
POT.
START-UP PROCEDURE
1. Turn gas supply to the “ON” position.
2. Depress the “MAIN POWER” switch to the “ON”
position.
3. Turn CPU to the “ON” position.
4. Select melt cycle or heat setting.
5. Select the desired temperature. See the
computer manual for more information.
SHUTDOWN PROCEDURE
1. Turn CPU off by pressing the “ON/OFF” button.
2. Depress the main power switch to the “OFF”
position.
3. Turn gas supply to the “OFF” position.
4. Wait fi ve minutes before restarting or
relighting fryer.
COOKING
Keating Instant Recovery® Gas Fryers are designed
to provide maximum production effi ciency and deliver
high quality food products.
Low - temperature cooking, highly polished stainless
steel and a true COLD ZONE mean extended oil life.
Follow the cooking procedures for your model.
CPU CONTROL PANEL SERIES 2000
CPU CONTROL PANEL SERIES 2009
CPU CONTROL PANEL SERIES 2010
COLD ZONE
CPU SPARK IGNITION SERIES 2000