5

If during operation the boil is killed when water au-
tomatically enters the pasta cooker, turn the water 
pressure down until the water is added without killing 
the boil. The drain terminates within inches of the 
fl oor and is designed for the standard dump to drain 
opening.

In most cases the health department will not allow a 
direct connection between the cooker drain and the 
fl oor receptacle. Contact your local health department 
for specifi c information in your area.

SETTING WATER LEVEL CONTROL BOARDS

To ensure the proper function of Keating's Custom 
Pasta System, the following steps must be taken:

As water quality varies from location to location, each 
new pasta cooker's automatic water fi ll board (B 
board) and safety board (A board) must be adjusted 
upon installation.

A or B Board

A Board Adjustment -

Keating's Custom Pasta System has a safety shut off 
feature to shut down the unit automatically when the 
water level becomes low. Use the following steps to 
properly set this feature:

1. Fill the unit to the "FILL LINE" with water.

2. Rotate potentiometer clockwise as far as 
possible.

NOTE:

 The potentiometer does not rotate 360°.

3. Ensure unit will heat properly (see OPERATING in 
    manual).

4. Slowly drain water.

NOTE:

 If unit does not shut down when water level is 

below the lower sensor (approximately at the top of 
heat tubes/elements), the following must be done:

5. Slowly rotate the potentiometer counter-clockwise
    until the unit shuts down.

6. Close drain valve. Repeat steps 1, 3 and 4.

B Board Adjustment (For Auto-Fill Units only) -

Auto-fi ll units automatically replenish the pasta cooker 
with water when water is absorbed in food and lost in 
the form of steam. Use the following steps to properly 
set this feature:

1. Fill the unit to the "FILL LINE" with water.

2. Rotate potentiometer clockwise as far as 
possible.

3. Slowly drain the water until level is visibly below 
    the "FILL LINE".

NOTE:

 If the blue light does not come on and the unit 

does not begin to refi ll with water, the following must 
be done:

4. Slowly rotate the potentiometer counter-clockwise
    until the blue light comes on.

5. Close drain valve. 

6. Ensure water stops fi lling when level is at the 
    "FILL LINE" (a slight turn of the potentiometer 
    clockwise may be necessary).

OPERATING

FILLING

NOTE:

 Before fi lling the Pasta System make certain 

the vessel is sanitized, dry and the drain valve is com-
pletely closed.

When the water fi ll toggle switch (located between 
the green and blue indicating lights) is turned on, the 
Pasta System vessel automatically will be fi lled to the 
proper level. If the vessel is being manually fi lled with 
water from a faucet or through the manual fi ll button, 
fi ll to just below the overfl ow deck. The black manual 
fi ll button is located to the right of the blue water fi ll 
indicating light.

THERMOSTATS

The Keating pasta cooker has two thermostats. This 
is to allow maximum control of the boil. The system 
is designed so that both thermostats will function 
together when called for but one thermostat will act as 
primary and hold the water at a rolling boil during cook-
ing as well as idle time. The two thermostats allow 
the user to have complete control over the cooking 
process.
The right side thermostat will only activate if the left 
side thermostat is active. From a cold start all ele-
ments and thermostats will be on and heat the water 
to a rolling boil. Once the water has reached a rolling 
boil the right side (secondary) thermostat will turn off 

Figure 2

Manual Water Fill Level

Содержание 14 Counter

Страница 1: ...rmed it is in your interest to obtain and keep all receipts Keating Custom Pasta System is not intended for household use As continuous product improvement occurs specifications may be changed without...

Страница 2: ...ND THE FOOD SERVICE SANITATION MANUAL OF THE FOOD AND DRUG ADMINISTRATION FDA 9902091 9902091 i Improper installation adjustment alteration service or maintenance can cause property damage injury or d...

Страница 3: ...UCTIONS Proper installation will assure top performance Alterations of any kind to your equipment will void the warranty Before uncrating check equipment carefully for damage IF EQUIPMENT ARRIVES DAMA...

Страница 4: ...Pasta Systems come with all the same features as the standard models The Basket Lift mechanism lowers the baskets of food into the water when the timer button is pressed and raises the baskets when th...

Страница 5: ...ND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER S IN STRUCTIONS THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN...

Страница 6: ...S 1 On Pasta System installations with casters the casters and jam nuts must be completely tightened Adequate means must also be provided to limit the movement of the appliance without depending on th...

Страница 7: ...water is absorbed in food and lost in the form of steam Use the following steps to properly set this feature 1 Fill the unit to the FILL LINE with water 2 Rotate potentiometer clockwise as far as pos...

Страница 8: ...on a regular basis to prevent water depos its from interfering with the sensor reaction Cleaning should be done with the brush up and down the sensor tube located on the right side of the splashdeck C...

Страница 9: ...stant footwear 2 Turn thermostats to OFF 3 After water cools drain the water 4 Turn Pasta System on and fill vessel with water See page 5 Filling UNDER NO CIRCUMSTANCES SHOULD THE PASTA SYSTEM BE LEFT...

Страница 10: ...close During the countdown the colon will flash at a one second rate When the countdown has reached 00 00 the relay output contacts will open the display will flash and the audible alarm will sound T...

Страница 11: ...Water Auto Fill and Low Water Safety Shut Off Systems The water supply connection located at the bottom rear of the Pasta System and marked water is a standard 3 8 female pipe connection The water pre...

Страница 12: ...IS DONE PRIOR TO SHIPMENT AT THE FACTORY IT SHOULD ONLY BE ADJUSTED BY A QUALIFIED SERVICE TECHNICIAN The potentiometer is located on the control board It is a black knob with a white triangle imprint...

Страница 13: ...ve the wire from the top sensor If filling begins replace the sensor Part 010212 e If water does not fill place a jumper wire across terminals A C on the B Board If filling begins replace B Board Part...

Страница 14: ...rmostat contacts do not close properly a Contact your electrician or the local power company and have the incoming power checked b Replace contactor c Tighten connections d Replace thermostat Basket L...

Страница 15: ...ARNING AND OPERATING PLATES All warning and operating plates on the Keating Pasta Cooker should be in place at all times If plates are damaged or lost replace them immediately PARTS LIST CUSTOM PASTA...

Страница 16: ...1 1 1 TERMINAL BLOCK 3P SMALL 002565 CIRCUIT BREAKER 40AMP 1P 012129 4 6 6 4 FUSE 300V 3AMP 004334 2 2 2 2 CONTACTOR 110V 3P 50AMP 011225 3 3 3 2 CONTRACTOR 110V 4P 40AMP 005597 1 TRANSFORMER STEPDOWN...

Страница 17: ...1 800 KEATING ELECTRIC CUSTOM PASTA SYSTEM SERIES 2009 15 WIRING DIAGRAMS 14 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...

Страница 18: ...keatingofchicago com 16 14 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM...

Страница 19: ...1 800 KEATING ELECTRIC CUSTOM PASTA SYSTEM SERIES 2009 17 14 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Страница 20: ...keatingofchicago com 18 14 ELECTRIC PASTA WITH BASKET LIFT AND DIGITAL TIMERS WIRING DIAGRAM...

Страница 21: ...1 800 KEATING ELECTRIC CUSTOM PASTA SYSTEM SERIES 2009 19 18 20 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Страница 22: ...keatingofchicago com 20 18 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...

Страница 23: ...1 800 KEATING ELECTRIC CUSTOM PASTA SYSTEM SERIES 2009 21 24 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM...

Страница 24: ......

Страница 25: ......

Страница 26: ...RANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE...

Отзывы: