KE2 Temp

 + Air Defrost

 (pn 20611)

For 

Medium Temperature

 Applications with 

Air Defrost

Installation Manual

This reference should remain on site with the 

installed KE2 Temp + Air Defrost controller.

Programming

  Press & hold ENTER button 

to access setpoint menu

  Use arrow buttons to 

select function:

tS    =  Temperature Setpoint

diF   =  

CSH  =  Max Compressor 

Starts/ Hour

dPd  =  Defrost Per Day

dFt  =  Defrost Time

LAO =  

tAd  =  Temp Alarm Delay

Adr  =  Mod Bus Address

Unt  =  Units for temp display

  Press ENTER & use arrows 

to change value

  Press & hold ENTER button 

Alarms

  When amber LED is lit:

SSA  =  Shorted Sensor Alarm

OSA  =  Open Sensor Alarm

HtA  =  High Temp Alarm

LtA  =  Low Temp Alarm

pn 20679  

 06/14

B

C

D

E

F

A

G

Parts List

The following parts are included in the KE2 Temp + Defrost kit:

  (1) KE2 Temp + Defrost controller
  (1) temperature sensor - 45”
  (4) self-tapping mounting screws
  (1) liquid tight cord grip 
  (1) sensor ziptie
  (1) programming sticker
  (2) screws for high voltage shield

Supplies List

All of the accessories required for the controller to work are supplied, 

however, standard truck stock items are required to install the controller. 

A list is provided below:

  conduit to go between the controller & evaporator
  (2) conduit connectors 
(straight or elbow as required)
  (4) high voltage wires matched to the load of the liquid line solenoid/

compressor and the controller.

  wire labeling (numbers, colors, etc.)
  additional wire ties
  18 gauge twisted shielded pair
 (if extending sensor wires)
  foam insulation (if running wires outside the space)
  silicone (for sealing any box penetrations)
  Cat5e cable (if setting up communications)

Select Mounting Location

The KE2 Temp is designed for a wide range of applications; therefore 

there are many potential installation locations. Breaking down the 

installation location by application provides the most helpful reference.

Application

Locations

Under counter

Evaporator cabinet
Outside controlled space

Walk-in

Evaporator cabinet
Adjacent to entrance

Side-by-side

Above door

Remote Monitoring, Control, Alarm Notifications

The KE2 Temp includes RS-485 Modbus communications and can be 

accessed remotely using the Alarms KE2 Edge Manager (KE2 EM). See 

page 4 for additional details.

Service Call Saver - 

Post Defrost Indicator

To eliminate unnecessary service calls, the KE2 Temp + Defrost alerts 

the user when it is coming out of a defrost cycle using the onboard 

display. The display alternates between dEF and the actual temperature 

measured by the air sensor. This continues until the temperature has 

reached setpoint, or for the amount of time set by dFt (Defrost Time) 

whichever is shorter.

Walk-in

Under Counter

Commercial

Wine Cabinet

A

C

D

E

B

F

G

Содержание Temp + Air Defrost

Страница 1: ...conduit connectors straight or elbow as required 4 high voltage wires matched to the load of the liquid line solenoid compressor and the controller wire labeling numbers colors etc additional wire ti...

Страница 2: ...ller first remove the display by loos ening the four corner screws The display is connected to the lower board by a short ribbon cable Caution The board may be damaged if excessive force is used when...

Страница 3: ...nnected in either orientation The sensor should be fed through the top conduit connection using liquid tight cord and before being attached to the board If Modbus communication is being used a water t...

Страница 4: ...2Temp KE2 LowTemp KE2 Adaptive Control Connect wirelessly to the KE2 EM Network ENTER BACK TM thermsolutions Evaporator Efficiency Press and hold for manual defrost KE2 Temp ENTER BACK TM thermsolutio...

Страница 5: ...t ENTER Press to move between the digits to accelerate the changes ENTER Press and hold to confirm each setpoint change BACK Press to escape Only visible if CUS custom is selected for dPd Defrost per...

Страница 6: ...od Bus Address 1 1 247 Unt Units for temp display FAH FAH CEL Selecting fewer than 5 compressor starts per hour results in the starts per hour feature being turned off The compressor will then functio...

Страница 7: ...am would be 2 Once the correct time is displayed press and hold the ENTER button until d1 is displayed d 2 i 1 2 d STEP 6 Repeat steps as necessary for d2 to d12 6 1 3 1 8 STEP 4 Press the up arrow u...

Страница 8: ...Q 3 20 Q 1 20 December 2020 and all prior publications 4 50 6 68 2 30 2 79 0 20 Hole 1 09 Top View End View 2 14 2 30 Dimensions Inches Wiring Diagram Ribbon Cable Air Temp Sensor 120 208 240 1 60 CON...

Отзывы: