background image

30

04/12/2017

rev.02

Italia 

Use and maintenance manual

6   Technical data

6.1   Technical features

Max. dimensions (mm)  and weight  (Kg/m

2

)

    Italia

Width

5000

Height

3600

Projection (awning open)

1800

Approx. weight (kg)

50

Roller tube (Ø)

70

Safety performance per EN13561

Wind resistance class

2

Nominal test pressure p(N/m

2

) α=1

70

Wind speed (Km/h)

38

Total transmittance of solar energy g

tot

see attached label

MOTOR

Type

see manual for installed motor

Specifications

CE marking, approved for sun awnings

For  the  specifications  of  the  optional  accessories,  see  Cap.9  “Optional”,  pag.31  and  the  corresponding 

instructions.

· The resistance to pooling water is tested with an inclination of 25%; retract the awning during rain if 

the angle is less than this.

· The maximum load permitted for non-retractable parts is 800 Pa.

· The resistance to pooling water is tested with an inclination of 25%; retract the awning during rain if 

the angle is less than this.

· The maximum load permitted for non-retractable parts is 800 Pa.

6.2   Technical label

The “technical label”, which is on the inside cover of this manual, specifies the year in which the CE marking, the 

manufacturer’s data and the specific product data were applied.

7   Transport and Installation

7.1   Transport

Transport and shipping shall be borne by the reseller and/or the manufacturer, who shall transport the product 

using adequate packages to protect it up until its delivery to the final customer.

Any damage to the product sustained during removal and subsequent handling and/or transport, 

performed after the initial installation, is not covered by warranty.

The packaging material must be disposed off and/or recycled according to the applicable local legislation.

7.2   Installation

Assembly of the components, installation and first start of the product must only be performed by 

specialised and qualified technicians, and is the responsibility of the reseller and/or manufacturer.

All the instructions and the main safety standards to perform these operations are described in the “Assembly 

Manual” and the “Installer Manual”.

Содержание Italia

Страница 1: ...Italia Use and maintenance manual Rev 02 15 12 2017...

Страница 2: ...5 3 1 Components 5 4 Intended use and installation location 6 5 Maintenance 8 5 1 Troubleshooting Table 8 5 2 Cleaning 9 5 3 Scheduled maintenance 9 5 4 Extraordinary maintenance 9 6 Technical data 1...

Страница 3: ...inary maintenance must only be performed by technicians trained and specialised for those tasks Contact Technical Support Do not place objects on the awning fabric It is forbidden for people to hang o...

Страница 4: ...12 2017 rev 02 Italia Use and maintenance manual ALL MEASUREMENTS ARE GIVEN IN MILLIMETRES UNLESS OTHERWISE INDICATED Some figures could be of a general nature and not be referred to the product at i...

Страница 5: ...al pag 31 3 1 Components The awning is composed of a metal structure and a fabric screen Metal structure this represents the supporting frame containing the various mechanisms required to open and clo...

Страница 6: ...user and other persons nearby It is strictly prohibited to climb on or hang place any objects from on the product The product must always be opened from top to bottom and never vice versa as it could...

Страница 7: ...as the system has an IP rating of IP55 or higher The space made available during the installation must take into account the space required for the movement and allow the product to open fully No ladd...

Страница 8: ...y forms cone Structure out of square Contact Technical Support Gust of wind Unroll the fabric and eliminate any folds Squeaking noise during movement of the product Impurities obstructions in moving p...

Страница 9: ...oth and a spray with PTFE teflon Qualified personnel are not required for ordinary maintenance operations The operations described below will keep the product in good condition if they are performed a...

Страница 10: ...is The maximum load permitted for non retractable parts is 800 Pa 6 2 Technical label The technical label which is on the inside cover of this manual specifies the year in which the CE marking the man...

Страница 11: ...vide on request only in motorized models WIND SENSOR automatically closes the awning in the event of strong wind The set point for the wind sensor anemometer operation is recorded during the first sta...

Страница 12: ...SOL 445 Bellvale Road Chester NY 10918 T 1 888 378 2765 F 1 845 692 1101 www keoutdoordesign us GENNIUS FRANCE sas Quartier Des 4 Chemins Zac Ducournau 83340 Flassans Sur Issole T 33 04 94781773 F 33...

Отзывы: