13
CONNECTING THE POWER SUPPLY /
HUBUNGKAN KE ARUS LISTRIK
Only direct connection to wall switch is allowed. (as diagram below) /
Hanya gunakan pemasangan terus sakelar pada tembok.
(seperti pada diagram di bawah ini)
Earth /
Arde
Wall Switch (OFF/ON)
Sakelar Dinding (OFF / ON)
230V 50Hz
Power Supply
Catudaya
Blue (Neutral) /
Biru (Netral)
Brown (Live) /
Coklat (Hidup)
Double pole single throw switch (Breaker Switch) /
Sakelar satu arah kutub dua (Sakelar Pemutus Arus)
Green/Yellow (Earth) /
Hijau/Kuning (Arde)
* Fan Image is for illustration purpose only. /
Gambar Kipas hanya untuk tujuan penggambaran.
WARNING /
PERINGATAN
This product is not provided with cord and plug or with other means for connection from the supply. When connect or
change the power cord or lead wire, it must be replaced by the competent personnel in order to avoid hazard. Please
use 227IEC53(RVV) or thickness of tube is 1mm or above. (Other requirements such as diameter of lead wire, please
use according to the regulation of the country). Can cause fire, explosion, short circuit, and electrical shock.
Produk ini tidak menyertakan kabel dan sakelar untuk hubungan atau pematian arus listrik. Gunakan kabel yang baik
dan berkualitas. Gunakan tipe 227IE53(RVV) atau yang ketebalan kawat lebih dari 1mm atau lebih. Gunakan syarat
dan ketentuan yang berlaku di masing-masing negara. Untuk menghindari kecelakaan, pemasangan kabel harus
dilakukan oleh orang yang berpengalaman. Dapat menyebabkan kebakaran, ledakan, korsleting, dan kejut listrik.
ATTENTION /
PERHATIAN
This product should be installed with a double poles single throw switch (Breaker Switch) with minimum 3mm contact gap in
the fixed installation circuit.
Do not use dimmer switch or regulator for this model. (It can damage the Ceiling Fan)
Produk ini harus diinstalasi dengan sakelar satu arah kutub dua (Sakelar Pemutus Arus) dengan minimum celah hubungan
3mm pada sirkit instalasi tetap.
Dilarang menggunakan alat pengatur atau sekelar peredup bagi produk ini. (Dapat merusak Kipas)
Regulator /
Alat Pengatur
Dimmer Switch /
Sakelar Peredup
0
5
4
3
2
1
0
5
4
1
Should there be a dimmer switch or regulator, disconnect it and reconnect the wiring as below.
Jika memakai sakelar peredup atau alat pengatur, matikan, dan hubungkan kembali seperti gambar di bawah.
Power Supply /
Catudaya
Connect Directly /
Disambung Langsung
Power Supply /
Catudaya
Connect Directly /
Disambung Langsung
Regulator /
Alat Pengatur
Dimmer Switch /
Sakelar Peredup
Motor /
Motor
Thermal Fuse /
Fuse Termal
MAIN PCB /
PCB UTAMA
CN2
CN1
Brown /
Coklat
Blue (Neutral) /
Biru (Netral)
Brown (Live) /
Coklat (Hidup)
Red /
Merah
Black /
Hitam
Green/Yellow (Earth) /
Hijau/Kuning (Arde)
White /
Putih
Switch /
Sakelar
Brown /
Coklat
Blue /
Biru
WIRING DIAGRAM /
DIAGRAM PERKABELAN