30

GB-Gas Wok Ring Table

Amicus- Gas-20190620

FR

M

-P

DE

-0

3-

04

(N

YT

/R

&

D/

20

18

10

08

)

Head Office

Jl. Raya Terboyo No. 19

Kawasan Industri Terboyo Megah

Semarang 50112, Central Java

Indonesia

T +62 24 6580 573

F +62 24 6580 572

E

[email protected]

Service Center

S +62 815 7575 7692

International Offices:

SINGAPORE

Nayati (Singapore) Pte Ltd,

627A Aljunied Road, #07-02

Biztech Centre

Singapore 389842

T +65 67471105

[email protected]

JIANGMEN

Nayati Jiangmen Trading Ltd 88,

Hong Xing Road, Block 3,

Phai Shi Feng Shan Industrial Park,

Third Floor, Jiangmen City,

Guangdong. Postal Code 529000

People’s Republic of China

T +(86)750 – 3229028 / 3229218

F +(86)750 - 3221208

Branch Offices

Local Offices:

JAKARTA

Jl. Batu Ceper 55 A

Jakarta Pusat 10120

Indonesia

T +62 21 384 6688

F +62 21 3890 1315

[email protected]

BANDUNG

Jl. BKR 19C, Kel.Pasirluyu,

Kec.Regol, Bandung 40254,

Indonesia

T +62 22 730 3336 – 7070 3589

F +62 22 730 3336

[email protected]

SEMARANG

Jl. Gajahmada NO.131

Semarang 50133, Indonesia

T +62 24 845 6011 – 845 6022

F +62 24 845 6770

[email protected]

SURABAYA

Jl. Kertajaya No. 41-43

Surabaya 60281, Indonesia

T +62 31 503 5844, 503 5049

F +62 31 503 1933

[email protected]

DENPASAR

Jl. Buluh Indah No.147

Denpasar 80119, Bali, Indonesia

T +62 361 418 921

F +62 361 503 1933

[email protected]

11. Addresses

A

dd

re

ss

es

Содержание NGWT 7-55/SN

Страница 1: ...BEDIENUNGSANLEITUNG KBS Gastrotechnik GmbH Scho bergstra e 26 65201 Wiesbaden www kbs gastrotechnik de Stand Juli 2022...

Страница 2: ...stallation Operation and Maintenance Instructions Model NGWT 7 55 SN Two Gas Open Burners Cast Iron Cap Wok Ring Adaptor Gas Wok Ring Table Note The picture is illustration only We reserved the right...

Страница 3: ...erials NAYATI Gas Wok Ring Table is excellent choice to cook In order to obtain maximum benefits of this appliance please read this manual instruction carefully Please notice the warnings and safety i...

Страница 4: ...sion 13 3 4 Components List 14 4 Handling and Installing 15 4 1 Packaging and Transport 15 4 2 Handling and Lifting 16 4 3 Safety Devices and Accessories 16 4 4 Position and Fixing 16 4 5 Gas Supply C...

Страница 5: ...information provided if necessary 1 2 Warning Signs and Symbols 1 2 1 Warning Warnings are indicated with a pictogram and a signal word The type and source of the risk as well as the consequences are...

Страница 6: ...action is required here 1 3 General Information of the Appliance Nayati Gas Wok Ring Table is an excellent cooking appliance made of stainless steel and cast iron It consists of two burners with 2 x...

Страница 7: ...gives 12 months guarantee with certain conditions NAYATI will decline any claims of accidents caused by improper use disobey rules and or disobey warnings Below are cases which invalidate the guarante...

Страница 8: ...ce in wet or humid room or condition such in rain or near water leaks etc 7 DO NOT use the appliance for drying clothes paper or living animals 8 DO NOT use the appliance to heat non food products 9 P...

Страница 9: ...ing Box Dimension mm 830 660 400 Cooking Surface WxD mm 330 Rate G30 11 5 kWx2 23 kW 19 780 kCal h G20 13 kWx2 26 kW 22 360 kCal h Gas Connection G R 3 4 Gas Supply Pressure G30 G31 28 30 37 mbar G30...

Страница 10: ...7 DE II2ELL3B P 20 50 DK II2H3B P 20 28 30 EE II2H3B P 20 28 30 ES II2H3 20 28 30 37 FI II2H3B P 20 28 30 FR II2E 3 20 25 28 30 37 GB II2H3 20 28 30 37 GR II2H3 20 28 30 37 HR II2H3B P 20 28 30 HU II2...

Страница 11: ...uctions of the appliance before operating it GR LU ier ce j uzst da saska ar sp k eso ajiem noteikumiem un to var darbin t tikai labi v din t vid Pirms ier ces uzst d anas un lieto anas p rliecinietie...

Страница 12: ...t tre limin conform ment la r glementation en vigueur ES II2H3 G20 2H 20 mbar G30 G31 3 28 30 37 mbar Esto aparato debe ser instalado conforme a las normas vigentes y setiene que utilizer solo en loca...

Страница 13: ...betjener apparatet skal du l se de relative instruktioner SE II2H3B P G20 2H 20 mbar G30 G31 3B P 28 30 mbar Denna apparat m ste installeras enligt g llande f reskrifter och f r endast anv ndas i v l...

Страница 14: ...13 GB Gas Wok Ring Table Amicus Gas 20190620 FRM PDE 03 04 NYT R D 20181008 3 3 Overall Dimension NGWT 7 55 SN Fig 2...

Страница 15: ...GS 4357B Air Chamber Mixing Jumbo Burner 2 6 GS 4358C Primary Air Adjuster Plate 2 7 GS 283D Nozzle Jumbo Burner 1 80 LPG 2 GS 283E Nozzle Jumbo Burner 3 05 LNG 2 8 GS 3851 Bunsen Pilot 2 9 GS 3828 N...

Страница 16: ...indicated by bubbles comes from the joints or pipefitting Another way is by looking at the gas counter If there is no movement on the gas counter it means no gas leakage 7 Before cleaning or maintain...

Страница 17: ...uate burned gases and cooking steams Below is construction type according to National Regulations A1 Appliance without fan and does not have connection to a flue or to a device for evacuating combusti...

Страница 18: ...k done according to professional standard with reference points that make it possible to find the pipes 6 Before installing Gas Wok Ring Table make sure that it is set for the gas and pressure see Tec...

Страница 19: ...main pressure while Gas Wok Ring Table is ON and using a pressure gauge for liquids for example U manometer with minimum resolution 0 1 mbar please follow direction below 1 Connect the flexible pipe E...

Страница 20: ...le 1 Lift the Burner 1 about 10 mm and pull from mixing chamber 3 2 Remove the fixing screw 2 This screw can be reach from below 3 Remove the complete mixing chamber 3 by turn anticlockwise from the N...

Страница 21: ...5 1 3 Adjusting Main Burner Minimum Rate 1 Access By Pass screw A of the gas tap after removing the handle and adjust it according to suitable gas Follow these instructions 1 Natural Gas G 20 Adjust B...

Страница 22: ...ned Full Closed Full Closed Adjusted G25 20 3 30 or Adjusted Reduced Heat Input Consumption 3 00 kW G30 0 907 kg h G31 0 893 kg h G20 1 376 m h G20 1 376 m h G25 1 600 m h WARNING After doing conversi...

Страница 23: ...c 3 User is only responsible for daily routine cleaning for maintenance 4 Qualified mechanic must do operations related to installation and maintenance according to Regulation in force 5 Use this Gas...

Страница 24: ...t the procedure 1 2 3 6 3 2 Turn Burner OFF 1 Turn the security Gas Control Knob to the 0 position 2 To extinguish the flame temporary turn the security Control Knob to the position At this position o...

Страница 25: ...20190620 FRM PDE 03 04 NYT R D 20181008 6 4 Suitable Wok and Pan Type 6 4 1 Suitable wok type which can be used for NGWT 3 55 Wok size 330 355 mm 6 4 2 Suitable pan type which can be used for NGWT 3 5...

Страница 26: ...a few minutes 5 Clean the plate thoroughly with a sponge rinse with plenty of water and dry 6 Clean the burners with mild detergent or using soap and water 7 Check the burners whether the holes are cl...

Страница 27: ...zle clogged Check and replace 2 Burner flame yellow Primary Air setting incorrect Check and repair Burner dirty Check and clean 3 Burner does not ignite Gas valve damaged Check and replace 4 Pilot fla...

Страница 28: ...27 GB Gas Wok Ring Table Amicus Gas 20190620 FRM PDE 03 04 NYT R D 20181008 9 CE Certificate CE Certificate...

Страница 29: ...28 GB Gas Wok Ring Table Amicus Gas 20190620 FRM PDE 03 04 NYT R D 20181008...

Страница 30: ...including fuses where no other fault exists Renewing of supply cable ends Fryers Replacement of components damaged by cooking oils due to a lack of cleaning and care when replacing oil Damage to therm...