KBR MWV measuring transducer adapter

Introduction

Safety notes

In order to prevent operating errors, handling of the device has been kept as 
simple as possible. This will enable you to use the device very quickly. Be sure to 
carefully read the following safety notes.

  

DANGEROUS VOLTAGE

The applicable DIN/VDE regulations must be observed for installation!

Power supply connection, setup and operation of the device may only be 
performed by qualifi ed personnel. Qualifi ed personnel as defi ned in the safety 
notes in this user manual are personnel with electrical engineering qualifi ca-
tions, knowledge of the national accident prevention regulations and safety 
engineering standards as well as of the installation, commissioning and opera-
tion of the device.
To prevent fi re and electric shock, do not expose the device to rain or moisture!
Before connecting the device to the power supply, check whether the local 
power supply conditions comply with the specifi cations on the device name-
plate.
A faulty connection may result in the destruction of the device!
When connecting the device, ensure that the data given in the connection 
chart is complied with (see "Connection diagram") and that the connection 
cables are not live. When wiring, always ensure that all wiring material used is 
neither damaged nor defective
and that the polarity is correct!
For proper and safe product operation, ensure that the device is transported, 
stored, installed, assembled, and carefully operated and maintained in accor-
dance with the specifi cations.
A visibly damaged device must generally be considered unfi t for use and dis-
connected from the power supply. Troubleshooting, repairs and maintenance 
work may only be carried out in our facilities or after contacting our service 
team.
Opening the device without authorization will render your warranty null and 
void. Correct operation can no longer be guaranteed!
All input and output cables of systems that are at risk from lightning strikes must 
be fi tted with lightning protection (see chapter "Protective measures" for recom-
mendations).

Содержание MWV

Страница 1: ...22062_EDEBDA0236 1218 1_EN User manual Technical parameters Your partner for network analysis Measuring transducer adapter MWV System I English ...

Страница 2: ... KBR Kompensationsanlagenbau GmbH Misprints printing errors and technical changes reserved 2 KBR MWV measuring transducer adapter ...

Страница 3: ... of contents Table of contents 3 Disclaimer 5 Safety notes 6 Product liability 7 Disposal 7 Scope of delivery 7 1 Application 8 1 1 The following transducer types are available 8 2 Installing the device 8 3 Connection diagram 9 4 Dimensions 10 5 Technical data 11 Table of contents ...

Страница 4: ...w how to prop erly install and start it up to prevent damage This user manual is included in the scope of delivery of the device and must be accessible to the user at all times e g in the switchgear cabinet Even if the device is resold to third parties the manual remains an inherent part of the device Although the utmost care has been taken in putting together this user manual errors may still occ...

Страница 5: ... means that minor injuries or property damage may occur if the appropriate safety precautions are not taken NOTE is an important piece of information on the product product handling or the respective part of the user manual to which special reference is made Disclaimer The contents of this manual have been checked to concur with the described hardware and software components However deviations may...

Страница 6: ... power supply conditions comply with the specifications on the device name plate A faulty connection may result in the destruction of the device When connecting the device ensure that the data given in the connection chart is complied with see Connection diagram and that the connection cables are not live When wiring always ensure that all wiring material used is neither damaged nor defective and ...

Страница 7: ...tails on product liability please refer to our general terms and conditions for electronic equipment The warranty on device properties applies only if the device has been operated in accordance with its intended use Disposal Devices that are faulty obsolete or no longer used must be properly disposed of If required we will dispose of the devices for you Scope of delivery Included in the scope of d...

Страница 8: ...ake sure that the measuring devices are configured for operation with a zero point creator 1 1 The following transducer types are available Type 400 100 Primary 400 V phase phase voltage IEC Secondary 100 V phase phase voltage IEC Type 600 86 Primary 600 V phase phase voltage UL NRTL Secondary 86 V phase phase voltage UL NRTL Type 700 100 Primary 700 V phase phase voltage IEC Secondary 100 V phase...

Страница 9: ...l2 k3 k3 l3 l3 Power Netz Measuring voltage Messspannung Measuring current Messstrom Stromflussrichtung current direction Die Abbildung zeigt im Auszug die Strom und Spannungseingänge des Messgerätes The diagram shows the current and voltage inputs of the measuring device DANGEROUS VOLTAGE The voltage inputs and outputs are not safe to touch CAUTION The device is not suitable for direct current ...

Страница 10: ...t the primary voltage with a back up fuse Include a disconnector or circuit breaker in the electrical installation of the building The disconnector must be close to the device and accessible to the user It must be marked as an isolating switch for this device The isolating switch must be UL IEC approved ...

Страница 11: ...low blow or C2 automatic Type 600 85 7 V UL NRTL Primary voltage 600 V Ph Ph Secondary voltage 85 7 V Ph Ph or 49 5 V Ph Mp Power Max 1 VA Housing DIN rail installation Weight Approx 650 g Dimensions Approx 87 x 72 mm Voltage input fuse Max 1 A slow blow or C2 automatic Type 700 100 V IEC Primary voltage 700 V Ph Ph Secondary voltage 100 V Ph Ph or 57 7 V Ph Mp Power Max 1 VA Housing DIN rail inst...

Страница 12: ...22062_EDEBDA0236 1218 1_EN Am Kiefernschlag 7 D 91126 Schwabach Germany P 49 0 9122 6373 0 F 49 0 9122 6373 83 E info kbr de www kbr de KBR Kompensationsanlagenbau GmbH ...

Отзывы: