O p e r a t i n g I n s t r u c t i o n s
|
KBL Tower pureEnergy
47
9.2 Maintenance intervals
MAINTENANCE PLAN
Component
500 h / 6 months
2000 h / 1 Y
ear
5000 h / 5 Y
ears
10000
h
/
10
Y
ears
Activity
Electronic
starters
X
Inspect and replace as
necessary
X
Replace
Acrylic panes
X
Inspect and replace as
necessary
X
Replace
Sleeve of the
door cable
entry
X
Inspect and replace as
necessary
Chassis and
associated
fasteners
X
Inspect and replace as
necessary
X
Replace
Wiring and
associated
plugs / terminal
connections
X
Inspect and replace as
necessary
X
Replace
Starter
decorative
lighting
X
Replace
Electrolytic
capacitors
X
Inspect and replace as
necessary
X
Replace
Contactors
X
Inspect and replace as
necessary
X
Replace
Component
After appr
ox.
250 operating
hours
After appr
ox.
500 operating
hours
After appr
ox.
1000
operating
hours
Activity
Tubes
X
Replace
aquaCool
nozzles
X
Inspect and replace
as necessary
X
Replace
Additional or recurring inspections
Every 6 months
cleaning service
Make sure that the inside and outside of the
tanning device is cleaned and free from dust,
fl uff or objects.
See 9.1 -> Operating Instructions, Inadequate
cleaning leads to overheating. As a result, this
can lead to damage of the tanning device.
Every 12 months
inspection
Please note that the tanning device must be
inspected regularly by a KBL authorized rep-
resentative every 12 months (from date of
installation) to maintain its proper condition!.
10 Years
inspection
If the tanning device is in use for longer than
10 years / 10000h, it must be completely
overhauled by qualifi ed, trained and autho-
rized service technicians.
On start up
If the tanning device has not been used for
a longer period of time, then it must fi rst be
inspected by qualifi ed, trained and authorized
service technicians before being put back into
operation.
Содержание Tower pureEnergy
Страница 1: ...OPERATING INSTRUCTIONS TANNING DEVICE ...
Страница 59: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 60 Remarks ...
Страница 61: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 62 Remarks ...
Страница 62: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...