background image

O p e r a t i n g   I n s t r u c t i o n s

 

|

 KBL Tower pureEnergy

30

DISPLAY 3

   / 

megaVoice: on/off

Back to previous/forward to next display

ADJUSTING THE BODY FAN

20-99  %,  off  (“off”  only  with  central 

exhaust-  air  module  and  only  within  the 

initial 7 operating minutes)

As  the  body  fan  is  also  used  for  cooling  down  the 

tanning unit, it is not always possible to decrease the 

power down to 20 %. The minimum possible power 

level depends on the temperature of the unit. 

• To decrease the fan power, press the minus button. 

• To increase the fan power, press the plus button. 

• To turn off the fan, reduce the power to 20 %, then 

press the minus button again and keep it pressed 

for 0.5 seconds. The fan is turned off after a delay.

ADJUSTING THE VOLUME (OPTIONAL FEATURE)

This section is only applicable to units with an audio 

option.

0-99 % 

While  the  volume  is  being  adjusted,  the 

value  is  displayed  to  the  right  of  the 

STOP button.

The  initial  value  is  set  via  AUDIO/VOL.HOT  and 

VOL.COOL in the service menu.

• To decrease the volume, press the minus button.

• To increase the volume, press the plus button. 

• To turn off the sound, use the minus button to set 

the value to 0.

SELECTING  THE  AUDIO  SOURCE  AND  TRACK 

(OPTIONAL FEATURE)

This section is only applicable to units with an audio 

option.  

SELECTING AN AUDIO SOURCE

The  audio  source  (

Wellness

Pop

  or 

Studio  Music

)  is 

selected  via  “P”  (=  program)  in  display  2.  However,  a 

selection is possible only on the condition that at least 

two sources are available and have been confi gured in 

the service menu.

After  the  start  of  the  tanning  program,  the  audio 

source defi ned as the default one in the service menu 

Содержание Tower pureEnergy

Страница 1: ...OPERATING INSTRUCTIONS TANNING DEVICE ...

Страница 2: ...ent and versions of the devices are in accordance with the legal prescriptions of the respective country of destination Export to the European Union of the KBL products listed in this guide or operation of the systems in these countries are not permitted KBL does not accept any manufacturers liability in case this direction is not adhered to It is expressly pointed out that any violation of the ex...

Страница 3: ...al timer 22 4 10 aquaCool and Aroma connections n a 4 11 aquaCool box connections 24 4 12 Connections aquaCool box tanning device 24 5 Start up 25 5 1 Operating modes 25 6 Tanning instructions 26 6 1 Instructions for the user 26 6 2 Exposure schedule 27 7 Tanning mode 28 7 1 Pre selection n a 7 2 Starting the tanning session 28 7 3 Operation during the tanning session 28 7 4 Basic functions n a 7 ...

Страница 4: ...es that due to UV radiation hazards exist to the human health This symbol indicates that due to fall ing loads hazards exist to the human health This symbol indicates the danger of pinching When closing and opening panels and covers you can pinch your hands This symbol indicates the danger of burns from hot lamps and housing parts If the tanning device was operated before being switched off and op...

Страница 5: ...ning device components is mounted on a pallet Insert the forks carefully into the openings of the pallet Lift the load by a few centimeters Transport the load carefully to the place of installation OTHER MODES OF TRANSPORT If a forklift truck cannot be used for transport the box must be unpacked and the parts inside must be transported individually to the place of installation e g using a dolly De...

Страница 6: ...e update To accomplish the update download the USB Connect software offered by KBL For detailed information press the help button in the main menu 1 9 Setup location OPERATION IN MOBILE FACILITIES CAUTION Crushing hazard caused by sudden movements The tanning device is unsuitable for oper ation in mobile facilities buses trains ships The tanning device must be adapted in order to ensure trouble fr...

Страница 7: ...ill be handed over ready for use As studio operator it is your responsability to observe the electrical regulations applicable at the installation site The tanning device incorporates special preventive measures with regard to the electromagnetic com patibility and must be installed and commissioned according to the EMC instructions obtained from this operating instructions If the tanning device h...

Страница 8: ...isinfection intervals are complied with especially the cleaning and dis infection of the tanning device after every use Make sure that your staff provides the customers with appropriate advice especially regarding tan ning times possible risks and the operation of the tanning device 1 13 Technical modifications The tanning device has been constructed in accor dance with current safety regulations T...

Страница 9: ...YPE III Often referred to as AVERAGE com plexion Burns moderately and tans about average SKIN TYPE IV This individual burns minimally tans easily and above average with each exposure SKIN TYPE V This individual rarely burns tans eas ily and substantially FURTHER INSTRUCTIONS WARNING No modification of this equipment is allowed Follow all instructions given in this manual In addi tion to that obser...

Страница 10: ...fering from sunburn by persons taking medicines by persons taking photosensitive medications by persons who had several severe sunburns as children by persons who are being treated by a physician for conditions associated with photosensitivity by persons who are prone to freckles by persons with atypical discolored skin areas or and with more than five atypical moles with a diameter of 5 millimete...

Страница 11: ... For cleaning the protective eyewear refer to chapter Instructions on cleaning disinfection and care 2 10 Freeing a trapped person Regardless of the operating state stand by or in operation of the tanning device the door can be opened manually from the inside or the outside eas ily and with very little effort any time The door drive mechanism is a purely mechanical function that does not depend on...

Страница 12: ...maintenance work make sure that all connectors are plugged into the socket housing to the end stop C l i c k 2 15 Exhaust air connection Danger of overheating Under no circumstances the ceiling fan shall be connected to anything Free and unobstructed airflow required Do not connect any air duct or vent to the ceiling fan Exhaust air system ...

Страница 13: ...take mitigation measures such as relocating or re orienting the equipment See EMC Tables according to 60601 1 2 2007 Table 1 Guidance and Manufacturer s Declaration Electromagnetic Emission KBL Tower pureEnergy is intended for use in the electromagnetic environment specified below The studio operator of KBL Tower pureEnergy should assure that it is used in such an environment Emission tests Compli...

Страница 14: ... be that of a typi cal commercial or hospital environment Surge voltages surges according to IEC 61000 4 5 1 kV differential mode voltage 2 kV common mode voltage 1 kV differential mode voltage 2 kV common mode voltage Mains power quality should be that of a typi cal commercial or hospital environment Voltage dips short interruptions and voltage variations on pow er supply input lines according to...

Страница 15: ...er and d is the recommended separa tion distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a are lower than the compliance level b in all frequency ranges Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher value applies NOTE 2 These guidelines may not apply in all ...

Страница 16: ...equipment Rated output of the transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 0 35ÖP 80 MHz to 800 MHz d 1 2ÖP 800 MHz to 2 5 GHz d 2 3ÖP 0 01 0 035 0 12 0 23 0 1 0 11 0 38 0 73 1 0 35 1 2 2 3 10 1 1 3 8 7 3 100 3 5 12 23 For transmitters rated at an output power not listed above the recommended separation distance can be determined using the equation ...

Страница 17: ...omprising 12 tubes each Rear part including 14 tubes and the interior con trol panel Door including 14 tubes Ceiling including fan Floor plate Casing of central exhaust air module optional equipment Door Exterior door handle Rear wall Ceiling grab handle Top crown Interior control panel Lateral part Floor plate Supply connections Interior door handle Ceiling fan ...

Страница 18: ...ode is only permitted in rooms with adequate ventilation Please take note of the information on and ensure minimum room hight technical data CONNECTED TO EXTERNAL EXHAUST AIR SYSTEM Danger of overheating by use of non original parts for exhaust connection The tanning device may only be connected to an external exhaust air system air duct or vent by using the original KBL central exhaust air module...

Страница 19: ...connection work and replacement of the power supply cord must only be performed by qualified trained and authorized service techni cians The connection to the 3 x 220 V mains must be protected by maximum over current protection For Canada a Class A ground fault circuit interrupter GFCI has to be used Further information can be found in chapter Technical data CONNECTION REQUIREMENTS The electrical ...

Страница 20: ...ut of the sound player or the headphone loudspeaker jack are available for connection 4 5 Level adjustment studio music signal The voice audio system components are installed in the back part of the tanning device Level adjustment is carried out via a potentiometer that is located on the audio switch circuit board To avoid overdrive select the level adjustment accordingly The level setting depends...

Страница 21: ...0 3 0 1 4 1 1 4 9 Connecting the external timer CONNECTING VIA AMP PLUG DEFAULT Connect the external timer e g coin box studio control according to the instructions supplied with the timer The connection is made via the socket for an AMP plug on the back side of the tanning device The following diagram shows the wiring of the timer connection timer L1 start remote start 11 13 1 2 socket for AMP pl...

Страница 22: ... i o n s KBL Tower pureEnergy 23 The exposure times stated in the expo sure schedule must be entered at the external timer Information on how to enter the expo sure time can be found in the operating instructions of your external timer ...

Страница 23: ... n s KBL Tower pureEnergy 24 4 11 aquaCool box connections 1 2 4 3 1 aquaCool liquid 2 aquaCool air blue 3 Mains voltage aquaCool box 4 Data cable Tanning device aquaCool Box 4 12 Connections aquaCool box tanning device aquaCool box Tower ...

Страница 24: ...tore these Operating Instructions in a place that allows for easy access at any time 5 1 Operating modes STANDBY MODE The tanning device is in an idle state i e it is connected to the mains but is currently not being used The tubes and the tanning lamps are switched off From the standby mode you can change over to the tanning mode or to the service mode TANNING MODE The tubes and the tanning lamps...

Страница 25: ... effects depend on the type and amount of radiation as well as on the individual sensitivity of the skin After excessive exposure to radiation the skin may exhibit sunburn Excessively repeated exposure to UV radiation of sunlight or UV appliances can result in premature ageing of the skin and in a higher risk of skin cancer Do not expose yourself to UV radiation if you take medicine that increase ...

Страница 26: ...orm users to use the supplied pro tective goggles that block UV rays Failure to use protective eyewear may result in severe burns or other eye injury If discomfort develops discontinue use and consult a physician 6 2 Exposure schedule For the precise definition of the skin types please refer to the supplied skin type table If the tanning session sequence is interrupted for 4 weeks or more you will...

Страница 27: ...d delay time has expired During the preset delay time the tanning session can be started anytime manually using the START button at the tanning device STOPPING THE TANNING SESSION Keep the STOP button pressed for at least two seconds As an acknowledgement you will hear a sound signal and the session time display starts flashing The session is discontinued but the time will continue to be counted T...

Страница 28: ...TOP 1 2 3 4 5 6 7 8 9 0 previouse Body fan Volume Next track for MP3 Channel selection for studio music aquaCool on off empty Back to previous forward to next display Display of session time and of change in volume and fan power DISPLAY 2 P Program Switching over between the audio sources configured in the service menu Wellness Pop and Studio The selected source is displayed briefly while changing...

Страница 29: ... ADJUSTING THE VOLUME OPTIONAL FEATURE This section is only applicable to units with an audio option 0 99 While the volume is being adjusted the value is displayed to the right of the STOP button The initial value is set via AUDIO VOL HOT and VOL COOL in the service menu To decrease the volume press the minus button To increase the volume press the plus button To turn off the sound use the minus b...

Страница 30: ... as follows Press the plus button above the symbol to jump to the following title channel Press the minus button below the symbol to jump to the previous title channel AQUACOOL OPTIONAL FEATURE On Off aquaCool canister is empty The initial value on or off is set via AAC AQUA AQUA in the service menu The cycle time is defined via the menu item AAC AQUA Cycle in the service menu This section only ap...

Страница 31: ...turn the decorative lighting on or off In addition to this manual procedure you can set a timer in the service menu to have two independent switch on and switch off times available 8 5 Invoking the service menu 1 2 3 4 5 6 7 8 9 0 _ _ _ _ _ START STOP 1 2 3 4 5 6 7 8 9 0 _ _ _ _ _ START STOP 1 3 2 4 2 1 3 The service menu can only be invoked from the standby mode Press the plus and minus buttons i...

Страница 32: ...PIN II STOP input PIN II C M marker down feature disabled marker up feature activated set with on the respective letter push START to save your choice entering PIN II functions on off C M 5 0 STOP START AUDIO audio system CH PULS BCD 4 9 channel selection procedure studio music 5 0 5 0 00003h TUBE tube hours 5 0 RESET h TUBE push 1 to reset the tube operating hours reset tube hours push START to s...

Страница 33: ... for example 30 03 07 FR enter date and time by pressing to the corresponding numbers The day of the week is determined automatically entering time date set time date 5 0 TIMER STOP START STOP MO SU 5 0 push START to select the desired day 5 0 5 0 timer function weekday selection AON 7 3 2 8 push START to save the selected value turnon time A AOF 7 3 2 8 push START to save the selected value turno...

Страница 34: ... in standby mode 5 0 5 0 VOL EC 10 99 4 9 push START to save the selected value volume of easycare STOP AAC AQUA STOP START STOP 5 0 5 0 5 0 Cycle 4 9 1 5 m push START to save the selected value STOP START STOP AQUA ON OFF 4 9 push START to save your choice AquaCool setting AquaCool setting AquaCool cycle time push START to save the selected value AQ Time 1 5s 4 9 setting AquaCool spraying time pr...

Страница 35: ...ART to save the selected value STOP 5 0 setting the operating hours of the tubes entering PIN II 5 0 SET LEVEL PIN III STOP START STOP entering PIN III factory settings Level III is exclusively reserved for trained service staff 5 0 easyCare easyCare 4 9 press START to save the selected value default session time easycare EC TIME 8 20m 5 0 EerDe xxx e g 035 erythema effective irradiance A STOP STA...

Страница 36: ...es Invoke the PIN II menu and enter the PIN Press 5 plus button or 0 minus button to select CPI Press START to open CPI RESET Keep 1 plus button pressed as long as necessary to set the hours to zero Press START to save the settings then exit the menu using the STOP button Use the menu item RESET h TUBE KBL5 to reset the operating hours of the tubes to zero These tube hours must be reset after each...

Страница 37: ...C menu Invoke the submenu by pressing START twice then press 5 plus button or 0 minus button to select AQUA Select AQUA ON by pressing 4 plus button or AQUA OFF by pressing 9 minus button Save the settings by pressing START and exit the menu by pressing the STOP button SETTING THE AQUACOOL CYCLE TIME The menu item AAC AQUA Cycle is used to set the interval between spraying cycles between 0 5 and 5...

Страница 38: ...n The maximum possible volume of the unit is at 100 Invoke the AUDIO menu Use START to invoke the submenu and press 5 plus button or 0 minus button to select VOL COOL Set the desired percentage by pressing 4 plus button or 9 minus button Press START to save the settings and STOP to exit the menu VOLUME OF EASYCARE Select the menu item AUDIO VOL EC in order to set the volume of the easyCare unit Th...

Страница 39: ...or 0 minus button Press the START button to display the corresponding information BASIC SETTINGS AQUACOOL ACTIVATING DEACTIVATING The menu item PIN II AQ is used to activate the aquaCool function top mark or to deactivate it bottom mark If the function has been deactivated the aquaCool symbol is not displayed and the studio customer cannot activate aquaCool Invoke the PIN II menu and enter the PIN...

Страница 40: ...RT to open the submenu and select EerLi or EerDe using 5 plus button or 0 minus button Exit the menu by pressing STOP TANNING CONTROL ONLY VIA EASYCARE You can determine whether easyCare can be deactivated or not Invoke the PIN II menu Select easyCare by pressing 5 plus button or 0 minus button Press the START button to open the submenu and select EConly using 5 plus button or 0 minus button Selec...

Страница 41: ...ncoming timer signal Invoke the PIN II menu Select easyCare by pressing 5 plus button or 0 minus button Open the submenu by pressing START and select EC REL TEST using 5 plus button or 0 minus button Press 1 minus button to start the test Press the STOP button to exit the menu ENTERING PIN III IfyouenteryourPINIllhere youwillaccessthenextservice level Level III is exclusively reserved for qualifie...

Страница 42: ...ly use original KBL ballasts for intelli gent control systems ICS and CPI En ergy tanning devices WARNING Injuries and damage caused by improper or insufficient maintenance Maintenance and care play a major role for the tanning devices performance and appear ance over its useful life Diligent compliance at the specified intervals is absolutely neces sary to ensure the proper operation of your tann...

Страница 43: ...zed Therefore switch off fuses before per forming any work and if possible remove them ADDITIONAL PROTECTIVE MEASURES Accidental reactivation may result in serious acci dents After deenergizing immediately secure all switches and fuses used for deenergizing against being switched on again Unscrew circuit breakers Where circuit breakers cannot be unscrewed a strip of adhesive tape can be applied ov...

Страница 44: ...isinfected for a specified amount of time This specified amount of time depends on the cleaner disinfectant which is used Follow the directions for use of the cleaner disinfectant After this specified application time remove remain ing cleaner disinfectant from the surfaces of the tanning device Use a single pass paper towel APPLICATION These symbols have the following meaning Apply the cleaning a...

Страница 45: ... amount of time depends on the cleaner disinfectant which is used Follow the direc tions for use of the cleaner disinfectant After this speci fied application time remove remaining cleaner disinfec tant from the surfaces of the tanning device After each tanning session Control panel Acrylic panes Directly on the surface Protective goggle Floor plate Directly on the surface Plastic surface of the d...

Страница 46: ...pprox 1000 operating hours Activity Tubes X Replace aquaCool nozzles X Inspect and replace as necessary X Replace Additional or recurring inspections Every 6 months cleaning service Make sure that the inside and outside of the tanning device is cleaned and free from dust fluff or objects See 9 1 Operating Instructions Inadequate cleaning leads to overheating As a result this can lead to damage of ...

Страница 47: ...ically pointed out 9 5 Acrylic panes The acrylic panels for the tanning devices are pro duced of acrylic glass developed especially for this application The acrylics used feature a particularly high UV permeability and resistance as well as an easy care hygienic surface that is gentle on the skin The instructions for cleaning and care must be observed The outer surface can be cleaned without any p...

Страница 48: ...wer When installing the tubes make sure that the tube inscription is visible If it is installed in a different position there will be no tanning effect After new tubes have been installed the operating hours of the tubes must be reset in the service menu WARNING Injuries and damage due to improper maintenance If the maintenance intervals for the UV lamps are exceeded or incompatible UV lamps are i...

Страница 49: ...can no longer be started Operating a lamp with a faulty starter significantly shortens its service life The lamp loses power and may begin to flicker under certain circumstances The starters are located in either one of the two lamp sockets or are visible when the lamps are removed 900 ⓐ ⓑ Þ Turn 90 and remove from the socket Attention Replace faulty starters immediately 9 11 Interior unit lightin...

Страница 50: ...n or adhesive tape inside outside PH2 Remove the two cross recess head screws Phil lips screws that hold the facing from the outside circles Undo the two hexagon head screws Allen screws M6 and remove the LED including cooling plate from the recess Disconnect the cable Proceed in reverse order to install the new LED 9 15 Recording to an SD card PH2 REMOVING THE SD CARD Remove the acrylic pane of t...

Страница 51: ...orted card sizes as well as file system and MP3 formats RECORDING TO THE SD CARD Attention Only change the data of the MUSIC MP3 player The SD card must only be formatted using FAT16 Using the SD Writer software down load from http www kbl support de software software html you can add or delete audio files to the SD card for music at your convenience These audio tracks are played if the correspond...

Страница 52: ...ards Unscrew the lid with the hose connections circle from the canister Place the hoses into a plastic bag so that they do not get dirty Replace the empty canister Fasten the lid with the connections on the new canister Attach the cover 4 Screw the cover 9 18 Replacing the aquaCool nozzles After 1 000 hours of operation the aquaCool nozzles must be replaced in order to ensure that the aquaCool sys...

Страница 53: ...One temperature sensor has not been found by the control system Replace the temperature sensor in the door contact your Customer Service 06 2 temperature sensors faulty 2 sensor f Both temperature sensors have not been found by the control system Ventilation works at 100 power Replace temperature sensors in the door contact your Customer Service 07 Aqua low The content of the aquaCool canister is ...

Страница 54: ... Electrical connection values Protective class IP 20 Mains voltage 3 phase operation 3x 220 V 60 Hz Wire cross section 3 phase 4x AWG 8 THHN cable in a isolation tubing e g flexible metallic conduit utilizing appropriate connectors Fuses 3 phase 3x 50 A For Canada with Class A ground fault circuit interrupter GFCI MP3 player Supports SD cards up to 1 2 GB SD 4 16 GB SDHC Supported file system SD c...

Страница 55: ...stances DIMENSIONS Front view Top view RHS view door opened RHS view with central exhaust air module 1395 mm 53 504 in 2326 mm 91 575 in 2406 mm 94 725 in Minimum room height in circulating air mode and exhaust air mode 1812 mm 71 339 in 2172 mm 85 512 in 347 mm 13 662 in 1224 mm 48 189 in ...

Страница 56: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 57 DISTANCES 3 16 in 2 76 in Distances apply to tanning devices with and without central exhaust air module 2 0 i n 20 in 20 in 1 1 5 i n ...

Страница 57: ...AND CONSULT A PYSICIAN ATTENTION RAYONNEMENTS ULTRAVIOLETS VEUILLEZ SUIVRE LES INTRUCTIONS SANS DISPOSITIF DE PROTECTION DES YEUX CE PRODUIT PEUT CAUSER DES BRÛLURES OU LÉSIONS OCULAIRES GRAVES SI VOUS SENTEZ UN MALAISE EN DISCONTINUER L USAGE ET CONSULTER UN MÉDECIN Part No 3010370800 DANGER Avoid overexposure As with natural sunlight overexposure can cause eye and skin injury and allergic reacti...

Страница 58: ...Y AND DISTRIBUTOR DISCLAIM ALL IMPLIED AND EXPRESSED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE 7 LIMITATION OF LIABILITY THE COMPANY OR DISTRIBUTOR SHALL NOT BE LIABLE WHETHER IN CONTRACT OR TORT FOR ANY LOSS OR DAMAGE INCLUDING BUT NOT LIMITED TO SPECIAL INDIRECT CONSEQUENTIAL PROPERTY ECONOMIC OR PERSONAL DAMAGES OF THE EN...

Страница 59: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 60 Remarks ...

Страница 60: ...egaLight o Orange aquaCool o Yes o No Music system incl musicVibration amplifier volume adjust only in combi nation with loudspeaker o Yes o No mp3 sound box only in combination with music system and loudspeaker o Yes o No megaTimer o Yes o No Exhaust air system o Without o Exhaust air duct o Exhaust air duct hose 300mm white length 3m 2 hose clamps o Three Phase Date of Install Installer Name and...

Страница 61: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 62 Remarks ...

Страница 62: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...

Отзывы:

Похожие инструкции для Tower pureEnergy