Technical data
Ambient conditions
Installation site
In dry rooms (booths) with sufficient airing and ventilation
• Maximum relative air humidity:
≤
70 %
• Maximum room temperature:
≤
30 °C
• Minimum height of the room: 2455 mm
Weights and measures
Dimensions in mm
(Height x width x depth)
1597 x 2397 x 1502 (when closed)
1998 x 2397 x 1502 (when open)
Bench pane
max. load capacity
150 kg
Weight
approx. 785 kg (with air conditioning)
Electrical connection values
Protective class
IP20
Mains voltage
400V / ~3N / 50Hz
Wire cross section
5 x 4mm
2
Ölflex
MP3-Player
• Supports SD cards up to 1-2 GB (SD) / 4-16 GB (SDHC)
• Supported file system (SD card): FAT16, FAT32
• Supported MP3 files: constant and variable bit rate, 96-320 Kbit/s
Fuses
Automatic fuse K-type (safety cut-out), 3-pole, 3 x 25A with residual current operated
circuit breaker (RCD)
Exhaust air
Fan
Exhaust-air socket Ø 300 -- 2150 mm (top) - Minimum exhaust air flow rate: 2250m
3
/h
Exhaust-air hose
Ø 300