34
Operation and Service megaSun 6900
6.
Technical data
6.1 Data which all devices have in common
Ambient conditions
Condensate
Dimensions of megaSun 6900
Installation site
in dry rooms with suf
fi
cient air supply and ventilation
Relative humidity
≤
70 %
Ambient temperature
≤
30°C
ATTENTION!
The unit must not be operated if the coin/timer system or
the internal control system of the maximum tanning time
is defective or if a
fi
lter is broken or missing.
Outlet
at the left-hand rear side of the unit
Disposal
Connection to sewage system or tank (capacity
≥
5l)
Quantity
Depending on local conditions and air humidity
Note
For the purpose of pumping the water off, the power
supply must not be disconnected after the tanning
session
Length x width x height
2360 x 1350 x 1400 mm when closed
2360 x 1350 x 1800 mm when opened
Central exhaust air duct
Diameter
Height (top edge)
300 mm
1600 mm
Exhaust air hose
Ø 300 mm
Weight (with air-
conditioning unit)
670 kg
Electrical data
Mains voltage
400 V/3N/50Hz
Fuses
Automatic fuse, K-type, 3 pole,
3x 25 A with ground fault circuit interrupter
Wire cross section
5 x 4 mm
2
Oil
fl
ex
Internal power outlet For PC, lamp etc., NOT for high loads.