REPLACING THE FILTER PANES
DANGER
Excessive UV radiation
Operating the tanning unit with defective fi lter
panes can result in serious injury to skin and eyes.
• Never operate the sunbed if the fi lter pane is not
present or defective.
• Carry out regular visual inspections.
• Replace fi lter panes only with ones of the same
type.
• Have the fi lter panes installed only by trained
technical personnel.
⑭
⑬
⑬
The pane is fi xed with two clamps each on
the two longitudinal edges.
⑭
Remove the pane from the spring retainer.
To do so, press the pane to be exchanged
slightly against a pair of clamps and, while
keeping it slightly pressed, tilt it out of the
holder on the relieved side.
Tubes
4
↵
•
When installing the tubes, make sure that the
tube inscription is visible. If it is installed in
a different position, there will be no tanning
effect.
•
After new tubes have been installed, the op-
erating hours of the tubes must be reset in
the service menu.
REMOVING TUBE
90
0
ⓐ
ⓑ
TUBE REPLACEMENT IN THE BENCH PART
⑮
⑮
⑮
Page
40
Open the bench pane.
⑮
If the sunbed is equipped with an air-
conditioning unit, remove the ducting pane.
⇒
Remove the tubes.