34
Operation and Service megaSun 4500
6. Service mode - inductive
The inductive controlled sunbeds are equipped with the KBL
processor /5 and the CPI controlled devices with the KBL pro-
zessor /4. The processor /4 used a serial interface for software
download. All functions (see chapter 7) are available in this sun-
bed.
There are two service levels that are both protected by pass-
words. In order to access these levels and to trigger any pro-
cesses, the touch keys 1 ... 0 have to be pressed. Therefore the
plus and minus keys bear numbers adjunct to them; the numb-
ers you see in the illustration below are slightly bigger than they
are in reality.In order to get access to the service pages, two
prerequisites have to be ful
fi
lled:
— there must not be any error message on the display
— there must not be any incoming signal from the coin/token
box system.
In case there is an error message pending you need to reset
this message by touching the „Stop“ sensor
fi
eld.
Figure 6-1 Touch keys 1 ... 0 for service operations
To access service level I,
fi
rst enter the sequence 1 6 1, and
then enter the PIN 1 1 1 1.
This level comprises service pages that may exclusively be
used by Technical Service staff. Service level II is accessed from
the level I menu “PIN II“ by entering the correct PIN.
You may leave both levels by pressing START. Any changes
made will be taken over and saved.
The menus available on the respective service level are entered
by pressing the touch keys 5 (forward) and 0 (back).
Differences
Service levels
Service level I
Service level II
Leaving the ser-
vice level
Menus available
on the service
levels