16
Operation and Service megaSun 4500
3.4.
Tubes and facial tanners
In order to be able to clean or replace the tubes or the facial
tanners, please carry out the procedure described below:
To make sure that the tanning effect is maintained, we recom-
mend cleaning the tubes and UV burners with warm water and a
chamois leather after approx. every 200 hours of operation. Do
not use any aggressive or alcoholic cleaning agents.
The coloured
fi
lter (Sec. 5.7 Unit lighting) has to be replaced at
the latest when replacing the tanning tubes.
Tubes, facial tanners and starters may only be replaced by ones
of the same type! When installing the tubes, make sure that the
inscription is visible, which means that the re
fl
ector of the tube is
at the rear side.
For units equipped with CPI technology, it is vital to carry out a
reset after each tube replacement! see
For units operated with inductive technology, also install new
starters with each tube replacement. Remember to set the wor-
king hours counter to zero. (see 6.1)
Dismantling
Unit lighting
Step
Procedure
Reference
1
Dismantle the canopy pane and the base pane
Section 3.2
2
For units equipped with burners
: You will have to remove
the
fi
lter panes for access to the burners in case you need
to replace them.
Section 3.3
3
When installing the tubes, make sure that the inscription is
visible, which means that the re
fl
ector is at the rear side.
4
When replacing the tubes, remember to install new starters!
All units with
burners
Inductive
units
CPI units
with facial tanners
without facial tanners
Burner
Tubes and
starters
Mode
Eco
Power
Eco
Power
500 - 600 hrs
500 – 600 hrs
800 hrs
500 hrs
1000 hrs
800 hrs
Zero setting - see section 6.1
Carry out a reset! See section 7.1