Operation and Service KBL 4000/4500
A clean exhaust air system in good working order prevents the
unit from overheating. The maximum length of the exhaust-air
hose of 6 metres must not be exceeded if there is no additional
fan.
Maintenance of
the exhaust-air
system and the
air-conditioning
unit
3.10. Air-conditioning unit
air hose leading to bed
outward condensate hose,
guiding the condensate
into a tank
condensate pump
condensate pan
Check the heat exchangers of the air-conditioning unit for dirt
particles each time a tube is replaced. Dirty heat exchangers
reduce the capacity of the air-conditioning unit.Open the late-
ral cover and vacuum-clean the heat exchangers, if necessary.
Check the connection hose each time the tubes are replaced.
Defective hoses must be replaced.
Check routine
Step
Procedure
Reference
1
Open the lower front cover and check the following items
regularly:
2
Check the air-conditioning unit and the condensate pump.
see section
3.10
3
The air hoses at the rear wall must not be kinked.
Figure 3-21
4
The fi lter mats in the base section and in the canopy must
be clean.
see also sec-
tion 3.8
5
Check whether the exhaust-air hose is kinked or damaged;
furthermore, check the working order of the additional fan in
cases where the hose length exceeds 6 m.
6
Adequate ventilation and air extraction both in the studio
and in the tanning booth must be ensured at all times.