background image

• LOCATE PRE-FILTER IN THE BOX AND INSTALL BEFORE INITIAL OPERATION.

Refer to “Removing/Changing the Filters” section for proper installation.

• Ensure the air purifier is plugged into a working electrical

outlet and the Power Knob is turned to the OFF position.

• Allow the unit to operate for a few seconds at turbo speed,

then leave the control knob in the turbo position for faster,
more powerful room cleaning, or move the knob to the
sleep setting for quieter operation.

It is recommended you run 
your air purifier 24 hours a
day to ensure continuous
cleaning. Portable air
purifiers are more effective
in rooms where all doors
and windows are closed.

(SLEEP)

(DAY)

(TURBO)

O   

(OFF)

The Intelli-Check

Filter Indicators serve as a convenient guideline for when to clean the

LifeTime HEPA

™ 

Permanent Filter and when to replace the carbon pre-filter.  Depending

upon your individual usage (environment and hours used), you may need to clean/replace
the filters more or less frequently.

When the 

HEPA Filter Indicator Light

 turns on, it’s time to clean your HEPA filter.  The

Intelli-Check

reminder for when to clean the HEPA filter is intended as a guideline only as

the performance of the filter media is dependent on the concentration of the contaminants
to which the system is exposed.  If there are sources of large amounts of contaminant
generation (such as dust from woodworking or heavy smoking) the HEPA filter in your air
purifier may need to be cleaned more often.  For instructions on how to clean your HEPA
filter, refer to section “Cleaning the LifeTime HEPA

Permanent Filter” in this manual.

Operation

Intelli-Check

Filter Indicator: 

Models 50150, 50200, 50250, 50300 Series

The air purifier model 50100 series is equipped with a Filter Maintenance Calendar
wheel which serves as a convenient reminder for you to check and replace the pre-filter
and clean the HEPA filter based on the air purifier’s hours of use.

Upon starting your air purifier and upon every pre-filter replacement, roll the pre-filter
change calendar ahead three months to indicate when the next filter replacement is
necessary. Upon starting your air purifier and upon every HEPA filter cleaning, roll the
HEPA filter calendar ahead 6 to 9 months (depending upon use) to indicate when
cleaning the HEPA filter is necessary.

Filter Maintenance Calendar: Model 50100 Series 

50000 series OM EFS.qxd  8/4/05  4:18 PM  Page 4

Содержание 50100

Страница 1: ...ean Air Portable True HEPA Air Purifiers READ AND SAVE THESE INSTRUCTIONS INSTALL PRE FILTER BEFORE USE Owner s Guide For LifeTime HEPA Permanent Filter Model Series 50100 50150 50200 50250 50300 Air Purifiers HEPA FILTER PREFILTER I II 0 50000 series OM EFS qxd 8 4 05 4 18 PM Page 1 ...

Страница 2: ...ear water in a bathroom laundry area or other damp location 11 The air purifier must be used in its upright position 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air purifier Do not block air outlets or intakes 13 Locate air purifier near the outlet and avoid using an extension cord 14 This appliance has a polarized plug ...

Страница 3: ...ne bacteria germs and mold spores by drawing air through the HEPA filter which traps and collects these particulates In a test lab the air purifiers were tested for reducing airborne pathogens that passed through the filter and results indicated a bacterial reduction up to 100 with a mean reduction of 99 3 For Best Performance Germ Reduction Construction Select a firm level and flat location For p...

Страница 4: ...n to clean the HEPA filter is intended as a guideline only as the performance of the filter media is dependent on the concentration of the contaminants to which the system is exposed If there are sources of large amounts of contaminant generation such as dust from woodworking or heavy smoking the HEPA filter in your air purifier may need to be cleaned more often For instructions on how to clean yo...

Страница 5: ...eaned or replaced as needed the filter indicator will need to be reset With the unit powered on press and hold the appropriate filter indicator button down for approximately 10 seconds until the light turns off Fig 1 CAUTION DISCONNECT FROM POWER SUPPLY BEFORE SERVICING Do not attempt to wash either the carbon pre filter or the HEPA filter They are not washable and washing will damage the filters ...

Страница 6: ... After vacuuming the filter wrap the pre filter around the HEPA filter and place the whole assembly back into the internal chamber of the air purifier see Removing Changing the Filters You now need to reset the Intelli Check Filter Indicator With the air purifier powered on press and hold the appropriate filter indicator button for approximately 10 seconds until the light turns off see Fig 1 Fig 5...

Страница 7: ...vice unwrap the HEPA filter install a new carbon pre filter and reinstall both filters in the air purifier See Removing Changing the Filters section for proper installation Cleaning and Storage My Air Purifier is starting to make noise and the air output is less What s wrong The filters may be dirty High amounts of contaminates can block the pores in the filter and stop the air from moving through...

Отзывы: