Do not dry out the air filter under direct sunshine or with fire.

For the one-way cassette type, the air filter should be installed 

before the unit body.

1

2

2. Dismantle the air filter.  

3. Clean the air filter 

4. Re-install the air filter.

5. Install and close the air-in grill by reversing step 1 and 2, 

   and connect the control box cables to the corresponding 

   terminators of the main body.

CAUTION

The air filter blocks dust. If the filter is blocked, the air 

conditioner will not work as well.

Clean the filter every two weeks when you use the unit is in 

regular use.

Clean the air filter with a vacuum cleaner or water.

a. The air-in side should face up when using a vacuum cleaner. 

    (Refer to Fig.5-13)

b. The air-in side should face down when using clean water. 

    (Refer to Fig.5-14)

For excessive dust, use a soft brush and natural detergent to 

clean it and dry in the cool place.

Fig.5-15

Fig.5-16

12

Owner’s manual

Inhalation grating

According to the figure shown in the position and 

direction of the arrow, press the filter and take it down. In 

the same way, take down the filter on the other side, and 

put it back after cleaning.

 ■ 

Air Out Louver 

(Adjustable)

Air Filter 

(Filters dust)

Air Intake 

(Intakes air)

Inhalation grating

Fig.5-11

Fig.5-12

Fig.5-13

Fig.5-14

 

When the power switch is connected, some energy will be 

consumed, even if the unit is not in operation. So please 

disconnect the power to save the energy.

A degree of dirt will be after several rounds of use so maintain 

carefully.

Take out of the batteries from the remove controller.

NOTE

Maintenance before stopping using the 

unit for a long time

 

(e.g., at the end of a season)

Let the indoor units run in fan only operation for about half a 

day to dry the interior of the unit.

Clean the air filter and indoor unit casing.

Refer to “Cleaning the air filter" for details on how to proceed, 

and make sure you install cleaned air filters back in the same 

position.

Turn off the unit with the ON/OFF button on the remote 

controller, and then unplug it.

Содержание SDV5

Страница 1: ...INDOOR UNITS SDV5 C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5 ...

Страница 2: ...Original instructions IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference ...

Страница 3: ...erform these tasks Do not dispose this product as unsorted waste It must be separately collected and processed Do not dispose of electrical appliances as unsorted waste They must be separately collected and processed Contact your local government for details If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and thus enter the food cha...

Страница 4: ...utdoor unit and don t place objects on it to avoid injury Falling or tumbling may result in injury Do not run the air conditioner when fumigating a room with insecticide as chemicals could get in the unit causing respiratory problems for people affected Failure to observe could cause the chemicals to become deposited in the unit which could endanger the health of those who are hypersensitive to ch...

Страница 5: ...opening Grounding Screw In the control box Air Intake Intakes air Air Out Air Out Louver Adjust the air out direction Fig 2 4 Fig 2 7 Fig 2 8 Fig 2 9 Air return grille Induced air decoration Dust filter Filter the dust in the induced air Grille bolt lock Lock the air return grille Air deflector Control the blow out direction of the air Display panel Display status information and receive the remot...

Страница 6: ...re pipe Outlet pipe Electric control box Fig 2 10 Fig 2 11 Fig 2 12 Fig 2 14 4 Low static pressure type Air Outlet Connects the duct Grounding Screw In the control box Control Box Air Intake Intakes room air Air Filter Filters dust Console type Air flow louver at air outlet Air inlet with air filter in it Installation part Display panel Drain pipe Air flow louver at air outlet Fig 2 15 Fig 2 13 Ai...

Страница 7: ...om air Air intake Intakes room air Air filter Filters dust Use the system in the following temperature range The max temperature for the air conditioner Cooling Heating 3 AIR CONDITIONER OPERATIONS AND PERFORMANCE Cooling operation Heating operating cooling only type without Mode Temperature Indoor temperature Using the unit outside of the accepted range may affect how it runs Please close doors a...

Страница 8: ...e louver direction Choose horizontal outlet mode for cooling Note the downward air flow will cause condensation on the air outlet and louver surface 1 2 Cooling operation Adjust the louver horizontally Four way cassette type Fig 4 1 Fig 4 2 To maintain a comfortable temperature Adjust the air out direction using the air out louver Please note the following correct operation for saving energy and a...

Страница 9: ...t the horizontal louver down when the air flow is down Horizontal louver Less than 40 2 The slant angle of horizontal louver must be less than 40 or water will drip from the unit vertical louver When adjusting air flow left right refer to the following figures to turn the vertical louver to certain angles Avoid angles that are too steep or water will drip from the unit NOTE The following section e...

Страница 10: ...not move the horizontal louver with hands or a malfunction may occur Adjust it with the swing button on the wire controller 1 2 3 Ceiling floor type Auto swing Press SWING for the louver to swing up and down left and right automatically Manual swing Adjust the louver to improve the cooling or heating effect When cooling Adjust the louver horizontally When heating Adjust the louver downwards vertic...

Страница 11: ...es the appropriate blowing pattern depending on the operating mode situation Air is blown via the upper air outlet so it doesn t directly blow onto people in Dry mode In all modes air is expelled from the upper air outlet Use this switch if you do not want air coming out of the lower air outlet when sleeping etc Operating mode Situation Blowing pattern COOL mode HEAT mode When the room is cool or ...

Страница 12: ...y two weeks when you use it regularly If the air conditioner is positioned in a dusty place clean the filter more often Replace the filter if it is too dusty too clean the replaceable air filter is an optional fitting 1 Take out the air in grill For Four Way Cassette Type Push the grill switches towards the middle simultaneously as indicated in Fig 5 1 Then pull down the air in grill Take out the ...

Страница 13: ...ows Fig 5 9 Fig 5 10 Take off the inhalation grating from the panel Air Outlet Selection Switch Special function filter For Console Type Push the grill switches in the directions of the arrows Then open the air in grill downwards Press the claws on the right and left of the air filter down slightly then pull upwards Fig 5 6 Hold the tabs of the frame and remove the claws in the four places The spe...

Страница 14: ...er s manual Inhalation grating According to the figure shown in the position and direction of the arrow press the filter and take it down In the same way take down the filter on the other side and put it back after cleaning Air Out Louver Adjustable Air Filter Filters dust Air Intake Intakes air Inhalation grating Fig 5 11 Fig 5 12 Fig 5 13 Fig 5 14 When the power switch is connected some energy w...

Страница 15: ...refrigerant caused by a flow stop or flow change A continuous sound is heard when the system is in cooling mode or has stopped The drain pump optional accessory makes this sound A squeaking sound is heard when the system stops after heating operation The expansion and contraction of plastic parts caused by temperature change make this noise Symptom 4 3 Outdoor unit The running noise may change due...

Страница 16: ...et of the indoor outdoor unit is blocked Doors and windows are open Sunlight is directly shining on the unit Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the power to resume Switch on the power Replace the fuse Replace the batteries or check the controller Set the temperature properly Wait Check leakage and rightly recharge the refrigerant ...

Страница 17: ...o the infrared signal receiver of the indoor unit and then press the ON OFF button twice The indication on the display disappears after a certain time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display The air conditioner operation will stop up to the set time The TIMER ON indicator goes off after a certain time Check whether the timer operation is ...

Страница 18: ...unit resumes automatically When the indoor unit is replaced with the correct one or is turned off the alarm will disappear Table 7 4 NO Type Contents Display content Remarks Room temp sensor is abnormal Indoor outdoor unit communication is abnormal Water level switch is abnormal Mode conflict E2 E1 EE E0 After the malfunctions disappear it restores automatically After the malfunctions disappear it...

Страница 19: ......

Страница 20: ... 01 01 2314 5 67 314 5 0738 9 71 20 01 7 1 7 8 9 9 0 90 2 8 3 07 11 5 3 07 11 71 11 011 7 3 A 71 3 0 3B1 07 C ...

Отзывы: