3
4. FUNCTIONS & FEATURES
Nested in the ceiling, space-saving and noble.
High capacity of cooling/heating, efficient, and energy-saving.
Innovative air supply, which provides homogeneous
conditioning of the room temperature.
Remote control or wire control function.
Low noise design,the A-weighted sound pressure level is below
70 dB.
The air outlet is laid out in the way you desire.
Use refrigerant to transmit cool/heat directly, which provides a
high transmitting efficiency.
It is suitable be used for office, hospital, commerical place
and home, the air conditioner will creat the comfortable and
elegance enviroment for you.
3. ELECTRIC SCAFETY REQUIREMENT
Wire distribution must be performed by duly qualified electricians.
All wire distribution must comply with electric safety specifications.
Ensure that the air coditioner is grounded properly. Namely, the
main switch of the air conditioner must have reliable ground wires.
Provide the air conditioner with a separate power supply compliant
with the nominal parameter values.
Electric performance requirements:
NOTE
12 hours preheating is imperative after turn on the power switch.
Please do not shut down the power when the unit is supposed
to stop running in 24h or shorter time. (This is to warm the
crankcase heat box to avoid compulsive start of condenser.)
Pay attention not to block the air inlet and outlet.
Blocks may decrease the efficiency of the unit or startup the
protector, which will stop running.
NOTE
Do not cut off the ground wire of the main power switch in any
circumstance.
Do not use damaged power wires. Change the damaged power
wires once they are detected.
Connect the power supply of the air conditioner for preheating
it for at least 12 hours before using the air conditioner. Besides
that, please be keep in mind that do not cut off the power supply
immediately, for the unit completely shut down needs to spend
a day-night.( In order to prevent the compressor drive-up by
forced, then heating the crankcase.)
Do not block the air inlet and outlet, if that so the performance
would reduce and the unit couldn’t be start for which protect
device is on service.
Type
Power supply
The main
switch
specification
Fuse
specification
Outdoor
unit
KUE 280 DN10
KUE 224 DN10
380-415V 3N~
50Hz
40A
40A
Indoor
unit
KPDH 224 DN10
KPDH 280 DN10
220-240V~
50Hz
16A
16A
Table 3-1
5. NAMES AND FUNCTIONS OF AIR
CONDITIONER COMPONENTS
Indoor unit
Electrical control box
Air return duct(option)
Remote controls signal
reciving board
Air outlet pipe, mute box(option)
Fixed rated wire controller
outdoor unit
Remote controller
(Option.)
Refrigerant pipe
Fig.5-1