15
Operation
AUTO-RESTART (on some models)
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting
automatically when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted operation in the first 3 minutes. This is to protect the unit.
Operation will automatically start after 3 minutes.
AIR FLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the air flow direction automatically:
-When the Power is ON, the louver opens fully.
-Press the SWING button on the panel or remote controller to initiate the Auto swing feature. The louver will
swing up and down automatically.
-Please do not adjust the louver manually.
POWER MANAGEMENT feature(optional)
When the ambient temperature is lower (Cooling mode) or higher (Heating mode) than the setting
temperature for a period, the unit will be automatically operating power management feature. The
compressor and fan motor stop and the power management indicator light
( ) illuminates.
When the ambient temperature is higher (Cooling mode) or lower (Heating mode) than the setting
temperature, the unit will be automatically quit the power management feature.
The power management indicator light turns dark and the
compressor and (or) fan motor run.
Water drainage
-During dehumidifying modes, remove the upper drain plug from the back of the unit, install the drain connector (5/8"
universal female mender) with 3/4" hose (locally purchased). For the models withoutdrain connector, just attach the drain
hose to the hole. Place the open end of the hose directly over the
Remove the upper drain plug
Continuous drain hose
√
During heating pump mode, remove the lower drain plug from the back of the unit, install the drain connector (5/8" universal female
mender) with 3/4" hose (locally purchased). For
the models without drain connector just attach the drain hose to the
hole. Place the open end of the Hose adaptor directly over the drain area in your basement floor. NOTE: Make sure the
hose is secure so there are no leaks.