background image

 

 

 
 
 

 

 

 

OWNER’S MANUAL 

 

Portable Air Conditioner 

 

 
 
 
 
 
 
 

KP-35 HN8 

 

 

 

 

 

 

 

 

Thank you for purchasing our Portable Air Conditioner.

 

Before using your air conditioner, please read this instruction manual carefully and keep it for 
future reference. READ AND SAVE THESE INSTRUCTIONS!

 

Содержание KP-35 HN8

Страница 1: ...Air Conditioner KP 35 HN8 Thank you for purchasing our Portable Air Conditioner Before using your air conditioner please read this instruction manual carefully and keep it for future reference READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...2 Contents Pre para t ion 3 Safety Precaut ions 5 Cautions 6 Installation 7 Operation 11 Maintenance 17 Faults Diagnosis 18 Design and Compliance Notes 19 Sociable Remark 20 ...

Страница 3: ...tically handle both sides Panel Caster upper air filter behind the grille upper air intake drain outlet air outlet lower air filter lower air intake drain outlet only for pump heating mode power cord outlet power cord buckle power plug socket bottom tray drain outlet rear ...

Страница 4: ...Preparation 4 NOTE The unit you purchased may be look like one of the following s ...

Страница 5: ...tionandto mitigate safety hazards DO NOT modify the length of the power cord or use an extension cord to power the unit DO NOT share a single outlet with other electrical appliances Improper power supply can cause fire or electrical shock Turn off the product when not in use DO NOT install your air conditioner in a wet room such as a bathroom or laundry room Too much exposure to water can cause el...

Страница 6: ... Prior to cleaning or other maintenance the appliance must be disconnected from the supply mains Do not remove any fixed covers Never use this appliance if it is not working properly or if it has been dropped or damaged Donotruncordundercarpeting Donotcovercordwiththrowrugs runners orsimilarcoverings Donotroute cord under furniture or appliances Arrange cord away from traffic area and where it wil...

Страница 7: ...ouse gases are contained in hermetically sealed equipment For specific information on the type the amount and the CO2 equivalent in tones of the fluorinated greenhouse gas on some models please refer to the relevant label on the unit itself Installation service maintenance and repair of this unit must be performed by a certified technician Product uninstallation and recycling must be performed by ...

Страница 8: ...mbly along the arrowdirectionforinstallation Hook Hole Seat Lower groove Make sure the adaptor is inserted into the lower groove of the air outlet Step Three Preparing the Adjustable Window Slider 1 Depending on the size of your window adjust the size of the window slider 2 If the length of the window requires two window sliders use the bolt to fasten the window sliders once they are adjusted to t...

Страница 9: ...msealA and B strips to the proper lengths andattachthemto thewindowsash andframe as shown Insert the window slider assembly into the window opening Foam seal C Non adhesive type Security Bracket 2 Screws Cut the non adhesive foam sealCstrip tomatch the width ofthe window Inserttheseal between the glass and the windowframetopreventair andinsectsfrom Getting into the room If desired install the secu...

Страница 10: ...cure the WallExhaustAdaptor Bto the wallusing the four Anchors and Screws providedin the kit Connectthe ExhaustHose Assembly with WallExhaustAdaptor A tothe Wall Exhaust AdaptorB Expansion anchor position Wall Exhaust Adaptor B Adaptor cap max 120cm or 47 inch min 30cm or 12 inch Note Cover the hole using the adaptor cap when not in use Note Toensureproper function DONOToverextendor bend thehose M...

Страница 11: ...ate operating mode Each time you press the button a mode is selected in a sequence that goes from AUTO COOL DRY FAN and HEAT cooling only models without The mode indicator light illuminates under the different mode settings Up and Down buttons Used to adjust increasing decreasing temperature settings in 1 C 1 F or 2 F increments in a range of 17 C 62 F to 30 C 86 F or 88 F or the TIMER setting in ...

Страница 12: ... the set temperature in C or F F no display for unit with POWER MANAGEMENT feature and the Auto timer settings While on DRY and FAN modes it shows the room temperature Shows Error codes and protection code E1 Room temperature sensor error E2 Evaporator temperature sensor error E3 Condenser temperature sensor error on some models E4 Display panel communication error EC Refrigerant leakage detection...

Страница 13: ...djust the temperature The fan motor operates at LOW Speed Keep windows and doors closed for the best dehumidifying effect Do not put the duct to window AUTO operation When you set the air conditioner in AUTO mode it will automatically select cooling heating cooling only models without or fan only operation depending on what temperature you have selected and the room temperature The air conditioner...

Страница 14: ...ed temperature will increase cooling or decrease heating by 1 C 2 F or 1 F 30 minutes The temperature will then increase cooling or decrease heating by another 1 C 2 F or 1 F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the Sleep Eco mode and the unit will continue to operate as originally prog...

Страница 15: ...wer management feature The compressor and fan motor stop and the power management indicator light illuminates When the ambient temperature is higher Cooling mode or lower Heating mode than the setting temperature the unit will be automatically quit the power management feature The power management indicator light turns dark and the compressor and or fan motor run Water drainage During dehumidifyin...

Страница 16: ...drain hose adaptor X drainhoseadaptor When the waterlevelofthe bottomtrayreaches apredeterminedlevel theunitbeeps8 times thedigitaldisplayareashows P1 Now theairconditioning dehumidification processwill immediatelystop However thefanmotorwill continuetooperate thisis normal Carefully movetheunittoadrainlocation removethe bottomdrainplugandlet thewaterdrainaway Reinstallthebottomdrainplugandrestart...

Страница 17: ...ection tray should be drained immediately after P1 error occurs and before storage to prevent mold In households with animals you will have to periodically wipe down the grill to prevent blocked airflow due to animal hair Clean the Unit Clean the unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Store the unit when not in use Drain the unit s water collec...

Страница 18: ...r is blocked Turnofftheunit disconnectthehose checkforblockageand reconnect the hose The unit is low on refrigerant Callaservicetechniciantoinspecttheunitandtopoffrefrigerant Temperature setting is too high Decrease the set temperature The windows and doors in the room are open Make sure all windows and doors are closed The room area is too large Double check the cooling area There are heat source...

Страница 19: ...without window slider adaptor or wall exhaust adaptor A as shown in the Installation section of this manual Unit Temperature Range Exhaust hose installation The exhaust hose and adaptor must be installed or removed in accordance with the usage mode For COOL HEAT heat pump type or AUTO mode must be installed exhaust hose For FAN DEHUMIDIIFY or HEAT electrical heat type mode must be removed exhaust ...

Страница 20: ... A The municipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least freeof charge C The manufacture will take back the old appliance for disposal at least free of charge tothe user D As old products contain valuable resources they can be sold to scrap me...

Страница 21: ...21 CP031IU PD DY XBGF 16120600A1133X ...

Страница 22: ...22 ...

Страница 23: ...23 ...

Страница 24: ...24 ...

Отзывы: